INSTALLATION INSTRUCTION FOR AUTOMATIC TOILET/URINAL FLUSH VALVE
Model Variation
Exploded View
Toilet Flush Valve
For TET2ANS-32
Water Supply Top Spud
AC
DC
TET2ANS-32
TET2DNS-32
TET2ANS-33
TET2DNS-33
TET2ANS-31
TET2DNS-31
Back Spud
Floor
Back Spud
Wall
Urinal Flush Valve
Specification
Installation Precautions
1. Prior to Installation
Prior to Installing your TOTO automatic flush valve,
install the items listed bellow:
· Closet fixture/Urinal fixture
· Drain line
· Water supply line
The supply piping to these devices shall be securely
anchored to the building structure to prevent the
installed device from unnecessary movement when
operated by the user. Care shall be exercised when
installing the device to prevent marring the exposed
significant surface.
2. Important
All plumbing is to be installed in accordance with
applicable codes and regulations.
Water supply lines must be sized to provide an
adequate volume of water for each fixture.
Flush all waterlines prior to operation.
The minimum pressure required to the valve is
determined by the type of fixture selected. Consult
fixture manufacturer for pressure requirement.
Do not use toothed tools to install or service the valve.
3. Main dimensions of the piping
*check local codes
Model
Number
Power
supply
TET2ANS
-32,33,31
Dimensions
(cover)
12-5/8"(H) x 14-3/16"(W)
(320mm(H) x 360mm(W))
Detection
range
Within 31-1/2"(800mm)
from the front of the flush valve
Detection
time
6 seconds or more
Ambient
temperature
32-104˚F(0-40˚C)
(water temperature: 34-104˚F(1-40˚C))
Connection
of the water
supply pipe
1"NPT 3/4"NPT
Supply
water
Pressure
Minimum required water pressure: 10 PSI (70kPa)
(flowing)
Maximum water pressure: 125PSI (862kPa)
Shutoff
pressure
7 PSI (48kPa)
Discharge
quantity per
flush at 28 PSI
(196kPa)
(Factory set)
Approx. 1.6 gallon
(6L)
Approx.0.5 ~ 1.0gallon
(1.9 ~ 3.8L)
(Fuzzy logic adjusted
flush volume)
10V DC
Supplied
by AC
Adapter
TET2DNS
-32,33,31
Alkaline
Type AA
Batteries
1.5V x 4pcs.
TEU2ANS
-11,21
10V DC
Supplied
by AC
Adapter
TEU2DNS
-11,21
Alkaline
Type AA
Batteries
1.5V x 4pcs.
For TEU2DNS-11
For TET2ANS-32
*check local codes
For TEU2DNS-11
4. Use care not to damage the surface of the infrared
sensor.
5. For Toilet Flush Valve
The toilet sensor valve may not function if toilet seat
and/or lid cover are left upright as it may block the
sensor.
6. For Urinal Flush Valve
The automatic flush valve is designed to be used with a
washout urinal for optimum performance. However, a
siphon jet urinal may also be substitutional. Blowout
urinals are not recommended.
7. The detection range of the infrared sensor is shown in
the figure below.
Do not install a handrail or any other object within the
detection zone of the sensor, as object blocking the
sensor may cause the valve to malfunction.
Additionally, to avoid the possibility of valve malfunction,
do not install the flush valve in a location where the
sensor faces a stainless wall, other highly reflective
surface or another infrared sensor.
Refer to local codes for special requirements.
Note
Detection zone
The detection zone is self-adjusting and is equipped with a
3-second flush delay after removal from the detection zone.
(No flush delay for Urinal flush valve)
The detection zone may differ according to color of user’s
clothes.
When a user wears black clothes, the detection zone may
become smaller and the valve may not flush.
“AVOID”
DO NOT
place the Infrared
sensor in front of a
stainless steel wall or other
highly reflective surface.
Stainless steel wall or other
highly reflective surface.
Infrared sensor of the
another automatic
flush valve.
Infrared sensor of the
automatic flush valve.
Item Figure Description Q’ty
1
D
Vacuum
Breaker tube
1
E
Control stop
1
F
Connection
wire
2
G
Tool
(Allen wrench)
1
H
Alkaline Type
AA Battery
4
I
Notice Label
1
J
Owner’s
manual
1
K
Installation
Instruction
(this manual)
1
L
Flush pipe
1
C
Box
Only for toilet flush valve
Installation
1. Required tools
Adjustable wrench, Phillips and slotted screwdrivers,
wire stripper and crimping pliers.
2. Inspection
Unpack the flush valve and carefully make sure the
cover, main unit and all other parts are included and
intact before starting installation of the product.
Item Figure Description Q’ty
A
Main body
(with a set of
valve)
1
Only for toilet flush valve
B
Front cover
(with an
infrared
sensor and
washer &
screw)
1
Manual flush button
(Only for toilet flush valve)
Installation Procedure
WARNING: To minimize the risk of electrical shock and
fire hazard, be sure to turn off and lock out
breaker for power line before starting the
installation.
Slide the stopper up and remove the bracket from the
button. (
A
)
Reinstall the bracket to the opposite direction shown in the
figure below. (
B )
Step 1
*For the Left water supply of Toilet flush valve
Original
for the right water supply
for the left water supply
DC Type Go to Step 4
Step 2
Install the optional transformer Model (THU701TR,
INPUT:120VAC,60Hz, OUTPUT:10VDC,1.95A or
THU700TR, INPUT:24VAC,60Hz, OUTPUT:10VDC,1.95A)
according the instructions given later in the “Installation of
the Transformer” section of this manual, mount the
junction box on a pillar or the like, and guide the two lead
wires from the secondary side (10VDC) of the transformer
to the junction box. Also guide the lead wires for multiple
junction boxes.
For AC Type
03666
To be continued on the back
Water Supply Back Spud
AC
DC
TEU2ANS-11
TEU2DNS-11
TEU2ANS-21
TEU2DNS-21
Flush pipe
3/4" O.D 1-1/4" O.D
AC Type
Only for toilet flush valve
Battery case
DC Type
AC Type
DC Type
DC Type
Toilet Flush Valve
TET2ANS-32
TET2DNS-32
TET2ANS-33
TET2DNS-33
TET2ANS-31
TET2DNS-31
TEU2ANS-21
TEU2DNS-21
TEU2DNS-11
TEU2ANS-11
Determine the installation of the box fixing frame based on
the toilet/urinal position. Then determine the location of
the water supply pipe and attach the control stop to the
pipe. Thereafter bore a flush pipe guide hole in the wall.
Slide a thread solder adapter on the water supply pipe if
applicable.
Attach the control stop before installing the box fixing frame.
Note
Figure
Figure
“AVOID”
DO NOT
place the Infrared
sensor of one urinal so that
it is in line with the sensor
of another automatic flush
valve sensor.
Infrared sensor of the
automatic flush valve.
4-3/4 1/2"
(120 13mm)
3-3/4"(95mm)
(For Max.1" wall)
1" NPT
Max.19-11/16"
(Max.500 mm)
Max.31-1/2"
(Max.800 mm)
15
Location of the Left water
supply pipe
1"NPT for Toilet
3/4" for Urinal
11-15/16"
(303mm)
Box fixing frame
Toilet top spud
(2-3/16"(56mm)Dia. hole)
Urinal Back spud
(1-5/16"(33mm)Dia. hole)
Toilet Back spud
(2-3/16"(55mm)Dia. hole)
4-3/4"
(120mm)
13-1/2"
(343mm)
4-3/4"
(120mm)
A B
Bracket
Stopper
Button
Location of the Right water
supply pipe
1"NPT for Toilet
3/4" for Urinal
1-9/16"
(40mm)
Water
supply pipe
11"
(279mm)
Adapter
16"
(406mm)
Bracket
1-1/2" O.D.
*16"(406mm)
4-3/4 1/2"
(120 13mm)
3-3/4"(95mm)
(For Max.1" wall)
3/4" NPT
*16"(406mm)
From the secondary side
of the transformer
Conduit tube
To junction box
Conduit tube
Junction box
Step 3
Join one lead wire, one supplied wire to flush valve and
one wire for another junction box using a wire nut. Join
the other sets of wires using another wire nut.
Fasten the connection wire to the cover of the junction
box.
To junction box
Wire nut
Supplied
connection wire
Fasten the connection wire
To flush valve
sensor
For AC Type
Step 4
Fasten the box to the box fixing frame with four screws (To
be prepare on the site) after adjusting it. (
A )
Secure the box with four screws attached to adjustable
plate. (
B )
Fasten the connection wire at the position of the mark
colored red with the clamp. (
C )
Adjustable
plate
Clamp
Adjustable hole
A
C
B
Box
Step 5
Pass the flush pipe and the vacuum breaker through the
hole bored in Step 1 and then mount them on the bowl.
Wall surface
Bowl
Top spud
1-1/2"
6 6-1/2"
(152 165mm)
3-3/4"
(95mm)
2-1/4" 2-3/4"
(57 70mm)
5"
(127mm)
Wall surface
Back spud
Wall mount
Bowl
3-3/4"
(95mm)
1-1/2"
3"
(76mm)
Step 6
Make sure that the O-ring fits in the groove of the
connecting pipe.
Step 7
Insert the end of the stainless cable for manual flushing
into the hinge hole. (
A )
Slide the cable casing into the opening of the bracket. (
B )
Make sure the rod of the flush valve is thrusted when the
button is pushed.
For Toilet flush valve
Before installing the cable, the bracket should be
reinstalled to the opposit direction.
(
C , and also see Step 1)
For the left water supply
Test Run
1. Energize the primary side of the transformer (THU701TR
or THU700TR) For AC Type
2. Make sure the control stop is open.
3. Sit on the toilet seat. (for Toilet flush valve)
Stand within two feet from the front of the flush valve.
(for Urinal flush valve)
4. Stay there for six seconds or more and leave the toilet
seat or the urinal. The valve will automatically flush.
5. Press the manual flushing button and make sure the
valve flushes properly. (for Toilet flush valve)
6. Recheck all the pipe connections for water leaks. If the
flush valve is not operating properly following the test
run consult the Troubleshooting section of the Owner’s
Manual. Recheck installation procedures only after
turning off and locking out breaker for power line
Note to the installer
After the flush valve unit has been installed correctly,
please explain to your customer how to use it and tell him
or her to observe the following instructions.
1. Do not put any object in front of the sensor window
which could obstruct the sensor, causing the flush valve
to malfunction.
2. For troubleshooting, consult the Owner’s Manual.
1 To minimize the risk of electrical shock and fire
hazard, turn off and lock out breaker for power line
before attempting troubleshooting, maintenance,
adjustment or repairs.
2 If you lack the necessary skills required or have
difficulty following the directions for installation,
maintenance, repairs, troubleshooting or
adjustments, of the product, do not proceed without
help from a qualified person to assist you in
performing any of these functions.
Adjustment
WARNING: To minimize the risk of electrical shock and
fire hazard, turn off and lock out breaker for
power line before starting adjustment.
1. Adjustment of the discharge quantity
(1) Remove the front cover.
(2) Adjust the discharge quantity by rotating the screw
on the piston valve.
Wiring
WARNING: To minimize the risk of electrical shock and
fire hazard, turn off and lock out breaker for
power line before starting wiring.
This product must be connected to the type of power
source indicated on the installation instruction. If you are
not sure of the type of power source available, consult
your dealer or local power company.
The wiring diagram is shown below.
When connecting the secondary side of the transformer
to each flush valve, use only UL Class ΙΙ No.18 wires.
- Wiring Diagram -
Installation of the Transformer
WARNING: Whenever installing the transformer or wiring,
turn off and lock out breaker for power line in
order to minimize the risk of electrical shock or
fire hazard.
2. Adjustment of the flow rate
Adjust the flow rate by turning the screw/handle of the
control stop.
Turn the screw/handle to the right to decrease the flow
rate and turn it to the left to increase.
3. Adjustment of the detection range
The detection range of the infrared sensor does not
need to be adjusted because it has been factory-preset.
This automatic flush valve unit requires a special
transformer. When installing the transformer, please
observe the following instruction.
1. The wiring distance from the transformer to the flush
valve must be 45 feet (13.5m) or less.
Use UL class ΙΙ No.18 wire when connecting the flush
valve to the transformer.
2. This transformer can be connected to a maximum of 10
flush valves.
WARNING: Be sure to ground the 4"SQ box to eliminate
the risk of electrical shock or fire hazard.
Never kink or bend primary-side lead wires
and/or secondary-side lead wires of the
transformer when wiring them in the conduit
tube or the junction box altogether.
4"SQ-2-1/4"DEEP
Primary-side lead wires
(120V or 24V AC)
Secondary-side lead wires
(10V DC,1.95A)
Condult tube
(CONDUCTKO’S)
Transformer
V1
V2
V1
V2
Unit #1
Solenoid valve
6VDC
Unit #2
Solenoid valve
6VDC
Junction box
Junction box
Two·pole beraker
Transformer
120VAC60Hz, to 10VDC(THU701TR)
1.95A
or
24VAC60Hz,to 10VDC(THU700TR)
1.95A
A maximum of ten units
can be connected.
Sensor
Sensor
For TET2ANS-32
TET2DNS-32
For TET2ANS-31
TET2DNS-31
Wall surface
Back spud
Floor mount
Bowl
3-3/4"
(95mm)
1-1/2"
Wall surface
3-3/4"
(95mm)
3/4"or 1-1/4"
For TET2ANS-33
TET2DNS-33
For TEU2ANS-11,21
TEU2DNS-11,21
Original
for the right water supply
for the left water supply
Cable casing
Stainless cable
Cable casing
Hinge
Bracket
Bracket
Hinge
A B C
Step 8
Tighten the coupling nut to prevent a water leak.
Coupling nut
Coupling nut
Step 11
For AC Type
Remove the battery case from the box.
Install the supplied 4 batteries into the battery case. Install
the battery case with the 4 batteries into the box exactly as
shown in the figure.
Connect the infrared sensor with the battery case by using
the connection wire.( A , B )
Connect the infrared sensor with the solenoid by using the
connection wire.( C , D )
For DC Type
B
A
C
D
Battery
Battery case
Screw (Not used)
Step 13
Fasten the front cover to the box by tightening the screws
with the supplied tool. (Allen wrench)
Take care so that any cord, wire or chain might not be
caught between the front cover and the box.
Manual flush button
(Only for toilet flush valve)
Allen wrench
For only AC Type
Step 10
Connect the chain from the front cover with a hole on the
Open the control stop.
Do not proceed to step 13 until all water leaks are
eliminated by tightening all the pipe connections. Failure to
correct all water leaks prior to use may increase the risk of
electrical shock, fire hazard or damage to the product.
Connect the flush valve with the control stop and the
vacuum breaker.
Step 9
Attach the connector of the infrared sensor unit with the
connector from the junction box. (
A
)
Attach the connector of the infrared sensor unit with the
connector from the solenoid by using connection wire.
(
B
, C )