Toto Clean Dry HDR110#SS Installation Manual

Page 1
INSTALLATION MANUAL Clean Dry™
High Speed Concealed Hand Dryer
Important Safeguards
(For your safety, please follow the instructions below.)
Warning
Ignoring these symbols may cause personal injury and/or property damage.
*Some models may have different components from the ones illustrated below.
This may cause product failure or damage.
Do not use in
humid area
Warning
Never attempt to disassemble for repair or modification.
This may cause electric shock, fire, injury or failure
Do not install outdoors or where it is exposed to water.
This may cause current leakage, electric shock, fire, or failure.
Do not
disassemble
Specification
0GU3049E 2009.04
Do not
Caution
Ignoring these symbols may cause severe injury and/or property damage.
Product HDR110#SS
Power Rating 120V AC, 4.25 Amps, 60 Hz, 510 W
Power Saving Function Automatically turns OFF after 60 seconds of use
58 dB
Ambient temperature 32° - 104°F (0° - 40°C)
Size
9-5/8" x 18-1/2" x 6-5/16"
Decibel Rating
Power Connection Hardwiring
224 mph (100 meters/second)
Air Speed
12 seconds
Dry Time
0.27 gal (950 ml)
Drain Tray Capacity
Weight
22.2 lbs (10kg)
Warning
It is necessary to install a circuit-breaker in the power supply
Failure to do this may cause electric shock during overload or short circuit.
Important
Caution
The chassis assembly must be installed on a smooth and even wall surface which has enough strength.
Failure to do this may cause damage or personal injury if it falls down.
Important
In this Instruction Manual, the following symbols are shown for safe and proper use of the product and to alert you of the possibility of personal injury and damage to your property. The symbols and their meanings are as follows:
Warranty Registration and Inquiry For product warranty registration, TOTO U.S.A. Inc. recommends online Warranty Registration. Please visit our web site http://www.totousa.com. If you have questions regarding warranty policy or coverage, please contact TOTO U.S.A. Inc., Customer Service Department, 1155 Southern Road, Morrow, GA 30260 (888) 295 8134 or (678)466-1300 when calling from outside of U.S.A.
HandDryerSupply.com | 804-859-2498 | sales@handdryersupply.com
Page 2
Before Installing
1.
Precautions
2. Others
Confirm the rough-in, major dimensions and wiring diagram before installation in order to properly install the hand dryer and electrical wiring.
All electrical wiring should be installed in accordance with national/local codes and regulations with assistance from a certified electrician.
Mounting surface should be even and smooth.
Confirmation must be made that the wall has enough strength for hand dryer installation and be sure to use all the mounting hardware provided to securely install the hand dryer.
It is necessary to install circuit breaker for the power supply.
Pay special attention so that both the top cover and the sensor surface are not flawed or scratched.
Do not place other devices using inverter or infrared sensor near the hand dryer, this may cause malfunction.
Set-up Drawing
Some models may have different components as illustrated below.
*
Recommended mounting bracket heights from floor are as follow:
- Male/Female: 29-1/2” (750 mm)
- Children: 23-1/2” (598 mm)
- Handicapped: 21-1/2” (547 mm)
Meets the American Disabilities Act Guidelines, ANSI A117.1 and CSA B651 requirements when mounted in a recessed wall where the front surface is not more than 4” (102mm) from finished wall and max. height of air blower outlet from finished floor is 47-1/4” (1200mm).
*
FLOOR
1-9/16″ (40mm)
3-9/16″ (90mm)
2-3/8″ (60mm) 2-3/8″ (60mm)
FINISHED WALL
OPEN WALL
1-9/16″ (40mm)
3-1/8″ (80mm)
2-3/4″ (70mm)
2-3/4″ (70mm)
1-3/16″ (30mm)
26-5/16
(668mm)
11-13/16″ (300mm)
5-1/8
(130mm)
1-5/16
(34mm)
2″ (50mm)
Junction box location
27-9/16″ - 27-5/8″ (700±2 mm)
1-9/16″ (40mm)
12-5/8″
(320mm)
28-3/4″
(730mm)
5-1/8″ (130mm)
6-7/16″
(164mm)
26-5/16″ (668mm)
9-15/16″ (252mm)
2″ (50mm)
HandDryerSupply.com | 804-859-2498 | sales@handdryersupply.com
Page 3
Installation
*Some models may have different component as illustrated below.
Hand Dryer Unit
w/o Top Cover
Accessories
Model is subject to change without further notification.
Mounting Bracket Screws and Vandal Resist Hex Wrench Template
Installation Manual
(φ4 .5 ×3 0) ×6
(M4 ×6 ) ×2
Bra ck et (Top)
Bra ck et (Bot to m)
Installation position
Installation position
Wiring Hole
Water Tray
Chassis Assy
Filter
Filter case
Top cover
Drain tray
Power Cable
<Botto m view>
Filter case
Wall surface
Sensor
Air nozzles
<View with cover removed>
Junction box
(Connection type)
Color : White,Black,Green
Size : AWG16×3
HandDryerSupply.com | 804-859-2498 | sales@handdryersupply.com
Page 4
Installation Procedure
To be continued on the back
Attach the bracket firmly on the rigid wall with the three screws (φ4.5×30)
provided.
In the case of a tile or concrete wall, please use plastic plug anchors with
screws provided.
Mark the wall with template and install the bracket
Caution
Chassis Assy. must be installed on a rigid and even surface
Failure to do this may cause damage or personal injury when it falls.
STEP 1
STEP 1
*
Recommended mounting bracket heights from floor are as follow:
- Male/Female: 29-1/2” (750 mm)
- Children: 23-1/2” (598 mm)
- Handicapped: 21-1/2” (547 mm)
1-9/16
(
40mm)
Finished wall
Finished wall
1-9/16
(40mm)
3-1/8
(80mm)
2-3/4
(70mm)
2-3/4
(70mm)
Bracket (Bottom)
Beam/Stud
1-9/16″ (40mm)
Wall
Finished Wall
Remove drain tray during installation
Junction box location
Drain tray
Wall thickness needs
to be 5 to 30mm.
Wall thickness needs
to be 5 to 30mm.
Bra cket (Top)
Beam/Stud
1
Using template provided, mark the wall for locations and install the mounting bracket.
2
Complete the electrical wiring; install the junction box, and connect the power cord using wire nuts.
3
Mount the chassis assembly and drain tray assembly
4
Install the top cover and drain tray
1-9/16 (40mm)
1-9/16
(40mm)
3-1/8
(80mm)
2-3/4
(70mm)
2-3/4
(70mm)
1-3/16
″ (30mm)
1-3/16
″ (30mm)
2
″ (50mm)
2
″ (50mm)
3-9/16″ (90mm)
2-3/8″ (60mm)
2-3/8″ (60mm)
3-9/16″ (90mm)
2-3/8″ (60mm)
2-3/8″ (60mm)
HandDryerSupply.com | 804-859-2498 | sales@handdryersupply.com
Page 5
STEP 2
STEP 3
STEP 2
Complete the electrical wiring
STEP 3
Mount the Chassis Assembly and Drain Tray Assembly
Connection
Diagram
Connect the cord firmly with a wire nut or equivalent.
・ ・
Make sure all electrical wiring is placed away inside the junction box. Use 2 screws (M4) that come with the product and tighten unit to the bottom
bracket.
Place chassis assembly onto the bottom bracket.Using wire nuts, connect power cable from hand dryer to power supply in the
junction box (confirm with certified electrician on correct wire nuts to use).
Place connection point (with wire nuts) into the junction box.Hang chassis assembly onto the top bracket.
Connection point
(Actual Placement)
Junction box
Place mounting platform onto mounting bracket ho oks.
Place connection point ( with wire nuts) into the junc tion box
(Actual Placement)
Junction box
Chassis Assy
Bracket (Top)
Bracket (Bottom)
Attach water tray after installation is complete
Screw in two screws onto bottom of body through the bott om bracket
(Actual Placement)
Junction box
Chassis Assembly
Drain tray
HandDryerSupply.com | 804-859-2498 | sales@handdryersupply.com
Page 6
1.
2.
After trial run
Test the product as follows after the installation is complete.
Check the circuit breaker
Check the functionality
Turn the circuit breaker ON.
Place your hand under the outlet nozzles to see if air blows out.
After you check the functionality by trial run, give the user manual (with warranty) to the customer, and explain how to use and maintain the product.
First peel off the seal on the filter. (The seal is used to protect the filter from scratches during shipment; it is no longer needed.)
B=BLACK R=RED W=WHITE Bu=BLUE G=GREEN
Sensor
Control Assembly
Motor
Power Connector
Power Fuse
Motor
G
B
W
W
B
W
W
P1-1
P1-2
P3
P2
P7
P6
15 A
G
Body Case
Function Test
1. Checking after installation
Wiring Diagram
Peel off the seal
Air nozzles
HandDryerSupply.com | 804-859-2498 | sales@handdryersupply.com