DIGITAL THERMOSTA T
Set Point Limiting Accepts EZ Programmer
3 Configurable Outputs
3 Configurable Outputs
Control up to 3 Heat &
Control up to 3 Heat &
2 Cool Stages
2 Cool Stages Adjustable 2nd & 3rd Stage Timers & Deadbands Backlit Display & Button Legends Aux Heat Indicator Dry Contact Equipped Outdoor Sensor Ready with High/Low Readouts for the Day
Accepts the
Accepts the
Use with most Air Conditioning & Heating Systems including: 1 or 2 Stage Electric Cooling & 3 Stage Gas Heating, Heat Pump, Electric or Hydronic Heat.
OPTIONAL
OPTIONAL
HUMIDITY MODULE
HUMIDITY MODULE
Economizer Control Preoccupancy Fan Purge Remote Averaging Programmable Output Light Activation Equipped Accepts Optional Humidity Module: Controls Humidification, Dehumidification and Reheat Accepts Optional IR Remote Control Optional Internet / Phone Control Accessory
COMMERCIALCOMMERCIAL
P374- P374- 29002900
Commercial Systems & Services Carrier Corporation 08/05
TOTALINE
Signature
TOTALINE
CAUTION
Follow the Installation Instructions before proceeding. Set the thermostat mode to “OFF” prior to changing settings in setup or restoring Factory Defaults.
CAUTION
NEVER PUT MORE THAN ONE JUMPER ON THE SAME MISC JUMPER BLOCK!
THIS MAY DAMAGE YOUR THERMOSTAT AND VOID YOUR WARRANTY.
MISC3
OK
NOTE: Due to variations in environmental conditions, it is not
always possible to achieve the desired humidification or dehumidification setpoint.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Thermostat P374-2900
Tested to Comply
c
with FCC Standards
C
F
4Z95
FOR HOME OR OFFICE USE
MISC3
Page i
Table of ContentsTable of Contents
TOTALINE
Preparation
Remove & Replace the Old Thermostat
Configuring the MISC Outputs
Wire Connections
Sample Wiring Diagrams
Test Operation
Calibrating the Thermostat Sensors
TroubleShooting
1 2 3 4 5 6 7 8
Page iii
SECTION 1
PreparationPreparation
1
Proper installation of the thermostat will be accomplished by following these step by step instructions. If you are unsure about any of these steps, call a qualified technician for assistance.
Assemble tools
TOTALINE
Flat Blade Screwdriver
Make sure your Heater/Air Conditioner is working properly before beginning installation of the thermostat.
Carefully unpack the thermostat. Save the screws, bracket, and instructions.
Turn off the power to the Heating/Air Conditioning system at the main fuse panel. Most residential systems have a separate breaker for disconnecting power to the furnace.
Wire cutter & Stripper
Page 1.1
SECTION 2
Remove & Replace the Old ThermostatRemove & Replace the Old Thermostat
TOTALINE
Remove the cover of the old thermostat. If it does not come off easily check for screws.
Loosen the screws holding the thermostat base or subbase to the wall, and lift away.
Disconnect the wires from the old thermostat. Tape the ends of the wires as you disconnect them, and mark them with the letter of the terminal for easy reconnection to the new thermostat.
Keep the old thermostat for reference purposes until your new thermostat is functioning properly.
2
Page 2.1
SECTION 3
Configuring the MISC OutputsConfiguring the MISC Outputs
3
Section 3 Contents:
Configuring the Jumpers........3.2
Explanation of Jumper
Settings..................................3.3
TOTALINE
Page 3.1
Configuring the JumpersConfiguring the Jumpers
TOTALINE
For additional flexibility, your thermostat has three configurable outputs. These outputs are designed to have different functions depending on how the jumpers are set (below). Each output, labeled MISC1, MISC2, and MISC3 may be set for one of the six choices available. In the diagram below, the MISC3 jumper has been set for HUM* (humidification) operation, the MISC2 jumper has been set for DEHUM* (dehumidification) operation, and the MISC1 jumper has been set for PROG (programmable) operation.
(FAN)
DEHUM
CKGND
PROG
ECON
MISC2
W3
HUM
W1
Y1
G
CK1
C
MISC3 MISC2 MISC1
R
ELEC
GAS
HP
GAS
2
4
INSTALL HUMIDITY
1
3
B
O
W2
MISC1
HUM
NO HUM
RS2
MISC3
RS+5
Z
8
6
X 1
RSGND
Y
579
Y2
(MISC1 ONLY)
MODULE WITH SENSING
ELEMENT OUTWARD
W3
PROG
HUM
DEHUM
ECON
MISC3 MISC2 MISC1
*The Humidity Module (sold separately) must be installed to operate a humidification and/or dehumidification system.
(MISC1
ONLY)
Y2
CAUTION
NEVER PUT MORE THAN
ONE JUMPER ON THE SAME
MISC JUMPER BLOCK!
DOING SO MAY DAMAGE
YOUR THERMOSTAT AND
VOID THE WARRANTY.
Page 3.2
MISC3
OK
MISC3