This manual covers the following models: P310-0110: For 1-Heat/1-Coot systems
P310-0210: For 2-Heat / 1-Cool heat pump systems (Remove the thermostat from its wallplate to find the model number.)
CAUTION: EQUIPMENT DAMAGE HAZARD. To prevent possible compressor damage, do not use Cooling mode when the outdoor temperature is below 50 °F (10 °C).
E0r assistance with this product please visit www.totaline.com
Read and save these instructions.
® U.S. Registered Trademark. Patents pending.
Operating Manual 570-207
i_1qFJ__
Overview
Thermostat features ............................. 1
Quick reference to controls .................. 2
Quick reference to display. ................. 3
Operation
System switch (Heat/Cool) ................... 4
Fan switch (Auto/On). ........................... 5
Temperature controls ............................ 6
Compressor protection ......................... 7
Appendices
Battery replacement ............................. 8
In case of difficulty ................................ 9
Customer assistance .......................... 10
Limited two-year warranty ................... 11
Totaline Basic 1H/1C & 2H/1C
Your new Totaline thermostat has been designed to give you many years of reliable service and easy-to-use, push-button climate control.
Features
Backlit display is easy to read
Displays ambient (measured) temperature at all times
One-touch access to setpoint temperature
Built-in compressor protection
Operating Manual 570-207
f2Tnm_IT__ i_ _ _
Screen
Lit for 12 seconds when
you press any button.
Up/Down buttons Press to adjust temperature
System switch (see page 4)
Cool: System is in Cooling mode.
Off: System is off.
Heat: System is in Heating mode.
•Em Heat: System is in Emergency Heat mode.
Fan switch (see page 5)
On: Fan runs continuously.
Auto: Fan runs onlywhen heating or cooling is activated.
Totaline Basic 1H/1C & 2H/1C
Low-battery warning (see page 8)
System status
Cool @ : Cooling is activated. *
Heat 8 : Heating is activated. *
Stg2: Auxiliary heat is activated. **
Setpoint indicator Appears when the setpoint temperature is displayed.
Temperature display The ambient (measured) temperature is normally displayed. To view the setpoint temperature, press either of the temperature adjustment buttons once. The setpoint temperature
will appear for five seconds.
* If Heat 8 or Cool _ is flashing, compressor protection is engaged (see page 7). ** Applies to P310-0210 model only.
Operating Manual 570-207
Use the System switch to place the system in one of the following modes.
Cool: System is in Cooling mode.
Off: System is off.
Heat: System is in Heating mode.
Em Heat: System is in Emergency Heat mode. Only auxiliary heating can be activated. The compressor is disabled. (This
mode is available on the P310-0210 model only.)
CAUTION: EQUIPMENT DAMAGE HAZARD
Do not use Cooling mode when the outdoor temperature is below 50 °F (10 °C).
!ii
Totaline Basic 1H/1C & 2H/1C
i_/ o i' ii
l__J o ,, iii
Use the Fan switch to select the fan
operation.
Auto: The fan runs only when heating or cooling is actually taking place (commonly used setting).
On: The fan runs continuously. Use this setting for improved air circulation or for more efficient air cleaning.
Operating Manual 570-207
_ Press the Up or Down button once to
i!_ _ display the setpoint temperature. 0_ Press either button more than once to
change the setpoint.
Totaline Basic 1H/1C & 2H/1C
I:t'!'11I11_E@liil_
Your thermostat has a feature that helps prevent damage to the compressor of your air conditioning or heat pump system. Because damage can occur if the compressor is restarted too soon after shutdown, this feature forces the compressor to wait 5 minutes before restarting. During the wait time, the message Cool e or Heat _ flashes on the screen. When the safe wait time has elapsed, the message stops flashing and the compressor turns on.
Operating Manual 570-207
NOTE: Batteries are optional (serving as backup power) only if your thermostat is connected to 24 VAC.
Set the System switch to Off before removing the batteries. Otherwise, the heating/cooling system could remain activated even when batteries are removed.
Install two fresh AAA batteries when the low-battery icon flashes on the screen. The icon appears for 60 days before the batteries
are depleted. Replace batteries once a year, or when you will be away for more
than a month. The settings are stored in non-volatile (permanent) memory and
are thus preserved when the thermostat is without AC power or batteries.
NOTE: The low-battery icon will not appear when the batteries are depleted if the thermostat is connected to 24 VAC.
Totaline Basic 1H/1C & 2H/1C
II11[_,_ mi _rliil_,A
Screen is blank.
Temperature settings cannot be changed.
Cool *_ or Heat # is flashing.
HI appears on the screen. LO appears on the screen. E1 appears on the screen. E2 appears on the screen.
Check circuit breaker and reset if necessary.
Ensure the heating/cooling system is powered up.
Ensure the furnace door is properly closed.
Ensure two fresh AAA alkaline batteries are correctly installed,
The System switch is off.
You are setting the temperatures outside their allowable ranges:
Heat: 40 °F to 90 °F (4.5 °C to 32 °C).
Cool: 50 °F to 99 °F (10 °C to 37 °C).
The compressor protection delay has been activated. Wait for the delay to end (maximum of 5 minutes).
The ambient (measured) temperature is above 122 °F (50 °C).
The ambient (measured) temperature is below 32 °F (0 °C).
The temperature sensor circuit is opened. Replace the thermostat.
The temperature sensor circuit is shorted. Replace the thermostat.
Operating Manual 570-207
[ 111" _ _1 "
For assistance with this product, visit our website at www.totaline.com.
10
Totaline Basic 1H/1C & 2H/1C
TWO-YEAR WARRANTY -- This CARRIER CORPORATION product is warranted to be free from defects in material and workmanship under normal use and maintenance for a period of two years from date of original installation. A new or remanufactured part to replace the defective part will be provided without charge for the part itself, through a qualified servicing CARRIER CORPORATION dealer or service, PROVIDED the defective part is returned to our distributor. The replacement part assumes the unused portion of the warranty.
THIS WARRANTY DOES NOT INCLUDE ANY ADDITIONAL LABOR ALLOWANCE OR OTHER COSTS incurred for diagnosis, repairing, removing, installing, shipping, servicing or handling of either
defective parts or replacement parts. SUCH COSTS MAY BE COVERED BY a separate warranty provided by the installer.
LIMITATIONS OF WARRANTIES -- ALL IMPLIED WARRANTIES (INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY) ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR
WHICH THE LIMITED WARRANTY IS GIVEN. THE EXPRESSED WARRANTIES MADE IN THiS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED, ENLARGED, OR CHANGED BY ANY
DISTRIBUTOR, DEALER, OR OTHER PERSON WHATSOEVER.
CARRIER WILL NOT BE RESPONSIBLE FOR:
1. Normal maintenance as outlined in the installation and servicing instructions or owners manual.