Unit Designation Schedule No.
Refrigerant Type R410A
Refrigerant Tubing Size (Flared) - 4 Ports
Outdoor Unit Data
System Ratings
Refrigerant Piping Data
MULTI ULTRA Ductless heat-pump systems 36,000 BTU
Reference
Submittal Data: TM36H5O
Approval
GENERAL FEATURES
-G10 DC Inverter Technology
-Quiet Operation - Both Indoor & Outdoor
-Blue Fin Coil Coating
-Intelligent Defrost
-Auto Restart on Power Outages
-Mulit-point Diagnostics
-Limited 5 yr Parts & Compressor Warranty-Residential Only
TosotComfort.Com
Compressor Type DC Inverter Driven Rotary
Rated Cooling Capacity 36,000 BTUH RLA 27.0 A
Starting Current
Cooling Capacity (min-max) 8,871-42,650 BTUH Fan Motor Output Power 90 W
FLA 1.0 A
Rated Heating Capacity 36,000 BTUH Air Flow (Max) 3,060 CFM
Construction
5.0 A
Heating Capacity (min-max) 8,871-42,514 BTUH Sound Pressure Level
Cooling 62 dB(A)
SEER/EER 23.0 / 9.0 Heating 62 dB(A)
Dimensions & Weights
HSPF/COP 10.0 / 3.21 Unit Dimensions Overall (WxDxH)* 42.8 x 17.3 x 43.4 -in
* including Valve Covers and Grilles
Weight (Net/Shipping) 280/298 lbs
Operating Range
Cooling (min-max)
Heating (min-max)
Power Supply Factory Charge for Total Line Length 131-ft
Normal Operational Voltage
Voltage Range
Main Power Wire Size
Interconnecting Cable Wire Size
MCA
MOCP/Breaker Size
208/230 V, 1 Phase, 60 Hz Total Refrigerant Pipe Length 246-ft
0 - 115°F Min. Number of Indoor Units 2
-18 - 46°C Max. Number of Indoor Units 4
-31 - 75°F Refrigerant Charge 158.8-oz
-35 - 24°C Additional Charge Per Line Length 0.2-oz/ft
1/4 x 3/8-in
187 - 253 V Max Refrigerant Piping Length to any Indoor Unit 82-ft
8-2 AWG Min Refrigerant Piping Length to any Indoor Unit 10-ft
14-4 AWG Max Elevation between Indoor Units 49-ft
36.0 A Max Lift from Outdoor to Indoor Unit 49-ft
60 A Max Drop from Outdoor to Indoor Unit 49-ft
© TosotComfort.Com 2019
@TOSOTCOMFORT
Features & Function Summary TM36H5O
ULTRA HEAT ULTRA COOL
Core Technology Three Cylinder Two Stage Compressor
See individual Indoor Unit
Controllers Functions
1
XK19 WIRED CONTROLLER FUNCTIONS
2
2
Note: Some indoor models may not support specific system features or functions.
SYSTEM FEATURES
Compressor Type
Inverter Rotary
G10
Ultra Low Frequency Torque Control Power Factor Correction Refrigerant Type Electronic Expansion Valve (EEV) 4 Basepan With Electric Heater Compressor Preheat Compressor With Electric Heater (-40°F) YES
-40°F Wiring UL Approved YES Multi "Independent" Port Design YES Condenser Fan Axial Condenser Motor Type DC Condenser Motor Drive Direct Condenser Coil Aluminum Fin/Copper Tube Outdoor Fin Coating (Blue) Intelligent Defrosting YES Low Voltage Startup YES Memory/Power Failure Recovery YES Self Diagnosis YES Ultra Heating (-31°F - 75°F) YES Ultra Cooling (0°F - 118°F) YES XK19 Wired Controller Interface YES
YES YES
R410A
YES YES
Acrylic Resin
REMOTE CONTROLLER FUNCTIONS
1
Not all Remote Controller functions are supported.
On/Off YES Operating Mode YES Fan Speed YES Room Setpoint YES Model Numbers YES Timer Mode YES Sleep Mode YES Turbo Mode YES X-Fan Mode YES Privacy Lock YES