Tosot TM18H5O Specifications

Inverter Heat Pump System
Job Name Location Date
Purchaser Engineer
Submitted To For
Unit Designation Schedule No.
Compressor Type DC Inverter Driven Rotary
7,000-26,000 BTUH Cooling 58 dB(A)
2
Max. Number of Indoor Units
Refrigerant Type R410A
Heating - Low Ambient (ULTRA)
Connection Method-Flared
System Ratings
Outdoor Unit Data
Refrigerant Piping Data
Multi ULTRA Ductless heat-pump systems 18,000 BTU
Submittal Data: TM18H5O
Reference Approval
GENERAL FEATURES
-G10 DC Inverter Technology - 2 Stage / 3 Cylinder
-Automatic Defrosting
-Compressor/Chassis Heaters
-Copper Tubing w/ Acrylicl-Resin Coated Aluminum Fins
-Intelligent Defrost
-Auto Restart on Power Outages
-Mulit-point Diagnostics
-Limited 5 yr Parts & Compressor Warranty-Residential Only
Rated Cooling Capacity 18,000 BTUH Starting Current 5.0 A
Fan Motor Output Power 90 W
Cooling Capacity (min-max) 6,998-21,001 BTUH FLA 0.4 A
Rated Heating Capacity 21,000 BTUH
Sound Pressure Level
Heating Capacity (min-max)
Heating 58 dB(A)
SEER/EER 23.0 / 12.5 Dimensions & Weights
Unit Dimensions Overall (WxDxH)* 39.5 x 16.8 x 31.1-in
HSPF/COP 10.5 / 3.6
Weight (Net/Shipping) 172/183 lbs
* including Valve Covers and Grilles
TosotComfort.com
RLA 14.9 A
Air Flow (Max) 2531 CFM
Construction
Operating Range
Cooling - Low/High Ambient
Power Supply Factory Charge for Total Line Length 66-ft
Normal Operational Voltage Voltage Range Main Power Wire Size Interconnecting Cable Wire Size MCA MOCP/Breaker Size
(min-max) 0 ~ 118°F
-18 ~ 48°C
(min-max) '-31 ~ 75°F
-
35 ~ 24°C Additional Charge Per Line Length 0.2-oz/ft
208/230 V, 1 Phase, 60 Hz Total Refrigerant Pipe Length 164-ft
187 - 253 V Max Refrigerant Piping Length to any Indoor Unit 82-ft
10-2 AWG Min Refrigerant Piping Length to any Indoor Unit 10-ft 14-4 AWG Max Elevation between Indoor Units 26-ft
23.0 A Max Lift from Outdoor to Indoor Unit 26-ft
© TosotComfort.Com
@TOSOTCOMFORT
Min. Number of Indoor Units
Refrigerant Charge 77.6 oz
35 A Max Drop from Outdoor to Indoor Unit 26-ft
2
1/4x3/8-in
Features & Function Summary
SYSTEM FEATURES
Compressor Type
Inverter Rotary
Core Technology Three Cylinder Two Stage Compressor
G10
See individual Indoor Unit
Controllers Functions
1
On/Off YES
2
Note: Some indoor models may not support specific system features or functions.
2
TM18H5O
Ultra Low Frequency Torque Control
Power Factor Correction Refrigerant Type
YES YES
R410A
Electronic Expansion Valve (EEV) 2 Basepan With Electric Heater Compressor Preheat
YES YES
Compressor With Electric Heater (-40°F) YES
-40°F Wiring UL Approved YES Multi "Independent" Port Design YES
Condenser Fan Axial
Condenser Motor Type DC
Condenser Motor Drive Direct Condenser Coil Aluminum Fin/Copper Tube Outdoor Fin Coating (Blue)
Acrylic Resin
Intelligent Defrosting YES Low Voltage Startup YES Memory/Power Failure Recovery YES Self Diagnosis YES Ultra Heating (-31°F - 75°F) YES Ultra Cooling (0°F - 118°F) YES XK19 Wired Controller Interface YES
REMOTE CONTROLLER FUNCTIONS
Not all Remote Controller functions are supported.
XK19 WIRED CONTROLLER FUNCTIONS
Operating Mode YES Fan Speed YES Room Setpoint YES Model Numbers YES Timer Mode YES Sleep Mode YES Turbo Mode YES X-Fan Mode YES Privacy Lock YES
1
© TosotComfort.Com
@TOSOTCOMFORT
Loading...