Tosot GWH09AAB-K6DNA4A/I, GWH12AAB-K6DNA3A/I, GWH09AAB-K6DNA3A/I, GWH09AAB-K6DNA2B/I, GWH12AAB-K6DNA1A/I Owner's Manual

...
Page 1
AIR CONDITIONER
Owner's Manual
Original Instructions
Split Air Conditioner
Thank you for choosing commercial air conditioners.Please read this Owner’ s Manual carefully before operation and retain it for future reference.
Page 2
GWH18AAD-K6DNA1B/I
GWH12AAB-K6DNA3A/I
GWH18AAD-K6DNA1A/I
GWH24AAD-K6DNA1A/I
GWH09AAB-K6DNA3A/I GWH09AAB-K6DNA1A/I
GWH12AAB-K6DNA1A/I
GWH24AAD-K6DNA5A/I
GWH18AAD-K6DNA5B/I GWH18AAD-K6DNA5A/I
GWH09AAB-K6DNA5A/I
GWH12AAB-K6DNA5A/I
GWH18AAD-K6DNA4A/I GWH18AAD-K6DNA4B/I
GWH24AAE-K6DNA4C/I GWH24AAD-K6DNA4A/I
GWH09AAB-K6DNA4A/I
GWH12AAB-K6DNA4A/I
GWH09AAB-K6DNA1B/I GWH09AAB-K6DNA2B/I
Page 3
The Refrigerant .....................................................................................................1
Safety precautions for installing and relocating the unit ......................................19
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from un­controlled waste disposal, recycle it responsibly to promote the sustainable reuse of mate­rial resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for envi­ronmental safe recycling.
Safety operation of flammable refrigerant............................................................16
R32: 675
Content
Operation Notices
Precautions............................................................................................................2
Parts name ............................................................................................................7
Screen Operation Guide
Buttons on remote controller .................................................................................8
Introduction for buttons on remote controller .........................................................8
Function introduction for combination buttons ......................................................11
Replacement of batteries in remote controller ......................................................11
Emergency operation ...........................................................................................11
Maintenance
Clean and maintenance........................................................................................12
Malfunction
Malfunction analysis .............................................................................................13
Installation Notice
Installation dimension diagram ............................................................................18
Tools for installation .............................................................................................20
Selection of installation location ..........................................................................20
Requirements for electric connection ..................................................................21
Installation
Installation of indoor unit......................................................................................22
Check after installation ........................................................................................27
Test and operation
Test operation ......................................................................................................27
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
If it needs to install, move or maintain the air conditioner, please contact dealer or local service center to conduct it at first. Air conditioner must be installed, moved or maintained by appointed unit. Otherwise, it may cause serious damage or personal injury or death.
Frequency band(s) in which the radio equipment operates2400MHz-2483.5MHz Maximum radio-frequency power transmitted in the frequency band(s) in which the radio equipment operates20dBm
Page 4
1
WARNING
To realize the function of the air conditioner unit, a special refrigerant circulates in the system. The used refrigerant is the fluoride R32, which is specially cleaned. The refrigerant is flammable and inodorous. Furthermore, it can leads to explosion under certain conditions. But the flammability of the refrigerant is very low. It can be ignited only by fire.
Compared to common refrigerants, R32 is a nonpolluting refrigerant with no harm to the ozonosphere. The influence upon the greenhouse effect is also lower. R32 has got very good thermodynamic features which lead to a really high energy efficiency. The units therefore need a less filling.
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacture. Should repair be necessary, contact your nea­rest authorized Service Centre. Any repairs carried out by unqualified personnel may be dangerous. The appliance shall be stored in a room without continuously operating ignition sources. (for example: open flames, an operating gas appliance or an operating electric heater.) Do not pierce or burn.
Appliance shall be installed, operated and stored in a room with a floor area larger than X . m
Appliance filled with flammable gas R32. For repairs, strictly follow manufacturer’s instructions only. Be aware that refrigrants not contain odour. Read specialist’s manual.
2
Appliance filled with flammable gas R32.
Before use the appliance, read the owner’s manual first.
Before repair the appliance, read the service manual first.
Before install the appliance, read the installation manual first.
(Please refer to table "a" in section of " Safety Operation of Inflammable
Refrigerant" for Space X.)
The Refrigerant
Page 5
Precautions
WARNING
Do not connect air conditioner to multi-purpose socket.
This appliance can be used by children aged from 8
Operation and Maintenance
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Do not spray water on indoor unit. It may cause electric shock or malfunction.
Otherwise, it may cause fire hazard.
Children shall not play with the appliance. Cleaning and user maintenance shall not be made by
children without supervision.
years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Do not wash the air conditioner with water to avoid electric shock.
After removing the filter, do not touch fins to avoid injury. Do not use fire or hair dryer to dry the filter to avoid
deformation or fire hazard.
Do disconnect power supply when cleaning air conditioner. Otherwise, it may cause electric shock.
.
2
Page 6
Precautions
Do not block air outlet or air inlet. It may cause malfunction.
remote controller may be broken.
Power cord is overheating or damaged.
There’s abnormal sound during operation.
Circuit break trips off frequently.
Air conditioner gives off burning smell.
Indoor unit is leaking.
contact the dealer or qualified professionals for service.
When turning on or turning off the unit by emergency operation switch, please press this switch with an insulating object other than metal.
outlet. It may cause personal injury or damage.
WARNING
conditioner and disconnect power immediately, and then
If the air conditioner operates under abnormal conditions, it may cause malfunction, electric shock or fire hazard.
Do not spill water on the remote controller, otherwise the
electric shock or damage. Please contact dealer when you need to repair air conditioner.
Do not repair air conditioner by yourself. It may cause
objects. It may cause damage or personal injury.
Do not step on top panel of outdoor unit, or put heavy
When below phenomenon occurs, please turn off air
Do not extend fingers or objects into air inlet or air
Maintenance must be performed by qualified professionals. Otherwise, it may cause personal injury
or damage.
3
Page 7
Precautions
Do install the circuit break. If not, it may cause malfunction.
of at least 3mm in all poles should be connected in fixed wiring.
magnet buckle
and heating buckle function, it can protect
the circuit-short and
overload.
power supply circuit and circuit break.
WARNING
note
the following table.Air switch should be included
Make sure the power supply matches with the requirement of air conditioner.Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
An all-pole disconnection switch having a contact separation
Must follow the electric safety regulations when installing the unit.
grounding wire of power socket.
Properly connect the live wire, neutral wire and
any work related to electricity and safety.
Be sure to cut off the power supply before proceeding
Including an circuit break with suitable capacity, please
Air Conditioner should be properly grounded. Incorrect
Don't use unqualified power cord.
grounding may cause electric shock.
According to the local safety regulations, use qualified
Installation must be performed by qualified professionals. Otherwise, it may cause personal injury or damage.
Attachment
4
Page 8
Precautions
Installation must be performed in accordance with the
persons in order to avoid a hazard.
must be properly grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock.
The appliance must be positioned so that the plug is accessible.
If the length of power connection wire is insufficient, please contact the supplier for a new one. Avoid extending the wire by yourself.
All wires of indoor unit and outdoor unit should be connected by a professional.
national wiring regulations.
requirement of NEC and CEC by authorized personnel only.
WARNING
wire, which can't be used for other purposes.
The grounding resistance should comply with national electric safety regulations.
The air conditioner is the first class electric appliance. It
keep the interconnection cable away from the copper tube.
The temperature of refrigerant circuit will be high, please
the manufacturer, its service agent or similarly qualified
If the supply cord is damaged, it must be replaced by
The yellow-green wire in air conditioner is grounding
The appliance shall be installed in accordance with
Do not put through the power before finishing installation.
5
Page 9
Precautions
The indoor unit should be installed close to the wall. Instructions for installation and use of this product are
provided by the manufacturer.
WARNING
place, only the qualified person can perform the work. Otherwise, it may cause personal injury or damage.
If you need to relocate the air conditioner to another
must be installed in the line.
For the air conditioner without plug, an circuit break
far away from animals or plants.If it is unavoidable, please add the fence for safety purpose.
Select a location which is out of reach for children and
reachable after finishing installation.
For the air conditioner with plug, the plug should be
Working temperature range
NOTICE:
6
Indoor side DB/WB(℃) Outdoor side DB/WB(℃)
Maximum cooling 32/23 43/26
Maximum heating 27/- 24/18
The operating temperature range (outdoor temperature) for cooling only unit is
-15℃~ 43℃; for heat pump unit is -15℃~ 43℃.
Page 10
(Display content or position may be different from above graphics, please refer to actual products)
Parts Name
Indoor Unit
remote controller
NOTICE:
Actual product may be different from above graphics, please refer to actual products.
7
(Display content or position may be different from above graphics, please refer to actual products)
air inlet
panel
aux.button
horizontal louver
air outlet
temp. indicator
power indicator
receiver window
Page 11
Introduction for buttons on remote controller
Buttons on remote controller
1
2
5
4
6
7
8
11
12
9
On/Off button
▲/ button
3
Fan button
Swing button
WiFi button
Turbo button
Light button
10
Temp button
I Feel button
Timer button
Sleep button
Mode button
Send signal
Turbo mode
8 heating function Set temperature
Set time
TIMER ON /TIMER OFF
Child lock
Up & down swing
Set fan speed
Light function
Temp. display type
:Set temp.
:Outdoor ambient temp.
:Indoor ambient temp.
Sleep mode
Heat mode
Fan mode
Dry mode
Cool mode
Auto mode
Operation mode
I feel function
X-fan mode
health function ventilation operation
2
5
7
9
4
12
3
1
6
8
10
11
NOTICE:
“ ” This is a general remote controller. Some models have this function while some do not. Please refer to the actual models.
Page 12

Note:
After putting through the power, the air conditioner will give out a sound. Operation indictor " " is ON (red indicator, the colour is different for different models). After that, you can operate the air conditioner by using remote controller.
Under on status, pressing the button on the remote controller, the signal icon " " on the display of remote controller will blink once and the air conditioner will give out a “de” sound, which means the signal has been sent to the air conditioner.
● Under off status, set temperature and clock icon will be displayed on the display of remote controller (If timer on, timer off and light functions are set, the corre­ sponding icons will be displayed on the display of remote controller at the same
time); Under on status, the display will show the corresponding set function icons.
▲ / button
4
Press / button to increase/decreaseset temperature. In AUTO mode, set temperature is not adjustable. When setting Timer On or Timer Off, press "▲"
Fan button
3
This button is used for setting Fan Speed in the sequence that goes from AUTO,
, to , then back to Auto.
On/Off button
1
Press this button to turn on the unit. Press this button again to turn off the unit.
Mode button
2
Each time you press this button,a mode is selected in a sequence that goes from AUTO, COOL, DRY, FAN, and HEAT *, as the following:
AUTO COOL DRY FAN
HEAT*
* Note: Only for models with heating function.
● This is a general use remote controller, it could be used for the air conditioners
with multifunction; For some function, which the model doesn't have, if press
the corresponding button on the remote controller that the unit will keep the
original running status.
or " " button to adjust the time.
Note:
● Fan speed under dry mode is low speed.
This function indicates that moisture on evaporator of indoor unit will be blowed after the unit is stopped to avoid mould.
Having set X-FAN function on: After turning off the unit by pressing ON/OFF
button indoor fan will continue running for a few minutes. at low speed. In this period, Hold fan speed button for 2s to stop indoor fan directly.
Having set X-FAN function off: After turning off the unit by pressing ON/OFF
button, the complete unit will be off directly.
X-FAN function
Hold fan speed button for 2s in COOL or DRY mode, the icon “ ” is
displayed and the indoor fan will continue operation for a few minutes in order to dry the indoor unit even though you have turned off the unit. After energization, X-FAN OFF is defaulted. X-FAN is not available in AUTO, FAN or HEAT mode.
Introduction for buttons on remote controller
Page 13
Press this button to start I FEEL function and " " will be displayed on the remote controller. After this function is set, the remote controller will send the detected
ambient temperature to the controller and the unit will automatically adjust the indoor temperature according to the detected temperature. Press this button again
to close I FEEL function and " " will disappear.
Note:
Outdoor temperature display is not available for some models. At that time, indoor
unit receives " " signal, while it displays indoor set temperature.
will change quickly if holding " " or " " button). Time setting range is 0.5~24hours. Press this button again to confirm timer setting and the characters of HOUR ON (OFF)will stop flashing.
If the characters are flashing but you haven’t press timer button,timer setting status will be quit after 5s.If timer is confirmer, press this button again to cancel
timer.
● Under ON status, press this button to set timer OFF; Under OFF status, press this button to set timer ON.
● Press this button once and the characters of HOUR ON (OFF) will flash to be
displayed. Meanwhile, press " " button or " " button to adjust timer setting (time
Press this button, you can see indoor set temperature, indoor ambient temperature
on indoor unit’s display. The setting on remote controller is selected circularly as below:
no display
Turbo button
Press this button to activate / deactivate the Turbo function Under COOL or HEAT mode.
Introduction for buttons on remote controller
10
▲ ▲
7
Temp button
8
10
9
11
Timer button
I Feel button
WiFi button
When I FEEL function is turned on, the remote controller should be put within the
area where indoor unit can receive the signal sent by the remote controller.
● This function is only available for some models.
Press " WiFi " button to turn on or turn off WiFi function. When WiFi function is turned on, the " WiFi " icon will be displayed on remote controller; Under status of unit off, press "MODE" and " WiFi " buttons simultaneously for 1s, WiFi module will restore to factory default setting.
Sleep button
6
Under Cool or Heat mode, press this button to turn on Sleep function. Press this button again to cancel Sleep function. Under FanDry and Auto modes, this function is unavailable.
Swing button
5
Press this button to set up & down swing angle.
Page 14
Emergency operation
If remote controller is lost or damaged, please use auxiliary button to turn on or turn off the air conditioner. The operation in details are as below:
air conditioner. When the air conditioner is turned on, it will operate under auto mode.
aux. button
panel
WARNING:
Use insulated object to press the auto button
Replacement of batteries in remote controller
11
Function introduction for combination buttons
Introduction for buttons on remote controller
Combination of "MODE" and " " buttons: About switch between Fahrenheit and centigrade
Nixie tube on the remote controller displays "SE". Repeat the operation to quit the function.
At unit OFF, press "MODE" and " " buttons simultaneously to
switch between and .
Combination of "TEMP" and "TIMER" buttons: About Energy-saving Function
Press "TEMP" and "TIMER" simultaneously in COOL mode to start e nergy-saving function.
(46 if Fahrenheit is adopted). Repeat the operation to quit the function.
Combination of "TEMP" and "TIMER" buttons: About 8
Heating Function
Press "TEMP" and "
TIMER
" simultaneously in HEAT mode to start 8℃ Heating Function
Nixie tube on the remote controller displays " " and a selected temperature of "8".
1. Press the back side of remote controller marked
the cover of battery box along the arrow direction.
2. Replace two 7# (AAA 1.5V) dry batteries, and make sure the position of "+" polar and "-" polar are correct.
3. Reinstall the cover of battery box.
signal sender battery
Cover of battery box
remove
reinstall
Combination of " " and " " buttons: About lock
Press " " and " "
buttons simultaneously 3s to lock or unlock the keypad. If the remote
three times.
controller is locked, is displayed. In this case, pressing any button, blinks
Press this button to
turn on the display's light and press this button again to turn
off the display's
light.
12
Light button
Page 15
NOTICE: Checking before use-season/Checking after use-season
■ The filter should be cleaned every three months. If there is much dust in the operation environment, clean frequency can be increased.
■ After removing the filter, do not touch fins to avoid injury.
■ Do not use fire or hair dryer to dry the filter to avoid deformation or fire hazard.
WARNING
Clean and Maintenance
1
2
3
4
Open panel
Pull out the panel to a certain angle as shown in the fig.
Remove the filter as in­dicated in the fig.
● Use dust catcher or water to clean the filter.
● When the filter is very dirty, use the water (below 45℃) to clean it, and then put it in a shady and cool place to dry.
Install the filter and then close the panel cover tightly.
12
Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock.
■ Do not wash the air conditioner with water to avoid electric shock.
■ Do not use volatile liquid to clean the air conditioner.
Clean surface of indoor unit
When the surface of indoor unit is dirty, it is recommended to use a soft dry cloth or wet cloth to wipe it.
● Do not remove the panel when cleaning it.
WARNING
NOTICE:
Page 16
13
Malfunction analysis
General phenomenon analysis
Please check below items before asking for maintenance. If the malfunction still
Phenomenon Check items Solution
Indoor unit can’t receive remote controller’s signal or remote controller has no action.
● Whether it's interfered severely
(such as static electricity, stable voltage)?
● Whether remote controller is
within the signal receiving range?
● Whether there are obstacles?
● Whether remote controller is
pointing at the receiving window?
● Is sensitivity of remote contro­ ller low; fuzzy display and no display?
● No display when operating
remote controller?
● Fluorescent lamp in room?
● Pull out the plug. Reinsert
the plug after about 3min, and then turn on the unit again.
● Signal receiving range is 8m.
● Remove obstacles.
Select proper angle and point
the remote controller at the re-
ceiving window on indoor unit.
● Check the batteries. If the
power of batteries is too low, please replace them.
Take the remote controller close to indoor unit.
and then try it again.
● Check whether remote cont-
roller appears to be damaged.
If yes, replace it.
No air
emitted from indoor unit
Air inlet or air outlet of indoor unit is blocked?
● Eliminate obstacles.
● Under heating mode, indoor
temperature is reached to set temperature?
After reaching to set temper- ature, indoor unit will stop bl-
owing out air.
● Heating mode is turned on just
now?
● In order to prevent blowing
out cold air, indoor unit will be
started after delaying for sev­ eral minutes, which is a nor-
mal phenomenon.
Page 17
Malfunction analysis
14
● Power failure?
● Is plug loose?
● Air switch trips off or fuse is burnt out?
● Wiring has malfunction?
● Unit has restarted immediately after stopping operation?
● Whether the function setting for remote controller is correct?
● Reset the function.
● Wait for 3min, and then turn on the unit again.
● Ask professional to replace it.
● Ask professional to replace air switch or fuse.
● Reinsert the plug.
● Wait until power recovery.
Air condit­ioner can’t operate
Mist is em­itted from indoor unit’s air outlet
● Indoor temperature and hum­ idity is high?
● Because indoor air is cooled rapidly. After a while, indoor temperature and humidity will be decrease and mist will disappear.
Phenomenon Check items Solution
Set temper­ature can’t be adjusted
● Unit is operating under auto mode?
Temperature can’t be adju- sted under auto mode. Please switch the operation mode if you need to adjust temperature.
Your required temperature exceeds the set temperature range?
● Set temperature range: 16℃~30℃.
Cooling
(heating)
effect is
not good.
V● oltage is too low?
● Wait until the voltage resumes normal.
● Filter is dirty?
● Set temperature is in proper range?
Adjust temperature to proper range.
● Door and window are open? ● Close door and window.
Odours are emitted
● Whether there’s odour source, such as furniture and cigarette, etc.
● Eliminate the odour source.
Page 18
■ When below phenomenon occurs, please turn off air conditioner and discon-
for service.
Malfunction analysis
15
Note: If there're other error codes, please contact qualified professionals for service.
Error code
E5/E6/E8/ U8/H3/H6
C5/F0/F1/F2
Troubleshooting
It can be eliminated after restarting the unit. If not, please
Error Code
Indoor display
Error code
Above indicator diagram is only
for reference. Please refer to actual product for the actual indicator and position.
● Power cord is overheating or damaged.
● Theres abnormal sound during operation. ● Air switch trips off frequently.
● Air conditioner gives off burning smell. ● Indoor unit is leaking.
■ If the air conditioner operates under abnormal conditions, it may cause
WARNING
● When air conditioner status is abnormal, temperature indicator on indoor unit will
ation of error code.
● Whether there’s inter­ ference, such as thunder,
wireless devices, etc.
● Disconnect power, put back power, and then turn on the unit again.
Air conditio­ner operates abnormally
Phenomenon Check items Solution
Water
noise
● Air conditioner is turned on or
turned off just now?
● The noise is the sound of
the unit, which is a normal phenomenon.
Cracking noise
● Air conditioner is turned on or
turned off just now?
● This is the sound of friction caused by expansion and/or
contraction of panel or other parts due to the change of
temperature.
Page 19
table a - Minimum room area ( m )
2
16
All the work men who are engaging in the refrigeration system should bear the valid certification awarded by the authoritative organization and the qualification for dealing with the refrigeration system recognized by this industry. If it needs other technician to maintain and repair the appliance, they should be supervised by the person who bears the qualification for using the flammable refrigerant.
It can only be repaired by the method suggested by the equipment’s manufacturer.
Safety operation of flammable refrigerant
Qualification requirement for installation and maintenance man
Installation notes
The air conditioner is not allowed to use in a room that has running fire (such as fire source, working coal gas ware, operating heater).
Maintenance notes
Welding
Check whether the maintenance area or the room area meet the requirement of the
nameplate.
- It’s only allowed to be operated in the rooms that meet the requirement of the
Check whether the maintenance area is well-ventilated.
- The continuous ventilation status should be kept during the operation process.
Check whether there is fire source or potential fire source in the maintenance area.
- The naked flame is prohibited in the maintenance area; and the “no smoking” warning board should be hanged.
nameplate.
Check whether the appliance mark is in good condition.
- Replace the vague or damaged warning mark.
If you should cut or weld the refrigerant system pipes in the process of maintaining, please follow the steps as below:
It is not allowed to drill hole or burn the connection pipe. The air conditioner must be installed in a room that is larger than the minimum room area. The minimum room area is shown on the nameplate or following table a. Leak test is a must after installation.
Charge amount (kg)
≤1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2 2.1 2.2 2.3 2.4 2.5
/
/
/
/
14.5 16.8 19.3 22 24.8 27.8 31 34.3 37.8 41.5 45.4 49.4 53.6
5.2 6.1 7 7.9 8.9 10 11.2 12.4 13.6 15 16.3 17.8 19.3
1.6 1.9 2.1 2.4 2.8 3.1 3.4 3.8 4.2 4.6 5 5.5 6
1.1 1.3 1.4 1.6 1.8 2.1 2.3 2.6 2.8 3.1 3.4 3.7 4
floor location
wall mounted
window mounted
ceiling mounted
Minimum
room
2
area( m )
Page 20
17
Safety operation of flammable refrigerant
Filling the refrigerant
Safety instructions for transportation and storage
a. Shut down the unit and cut power supply b. Eliminate the refrigerant c. Vacuuming d. Clean it with N2 gas e. Cutting or welding f. Carry back to the service spot for welding
The refrigerant should be recycled into the specialized storage tank.
Make sure that there isn’t any naked flame near the outlet of the vacuum pump and it’s well-ventilated.
Use the refrigerant filling appliances specialized for R32. Make sure that different
kinds of refrigerant won’t contaminate with each other.
After filling is finished, please do the leakage detection before test running; another
time of leak detection should be done when it’s removed.
Please use the flammable gas detector to check before unload and open the container.
No fire source and smoking.
According to the local rules and laws.
The refrigerant tank should be kept upright at the time of filling refrigerant.
Stick the label on the system after filling is finished (or haven’t finished).
Don’t overfilling.
Page 21
18
Installation dimension diagram
At least 250cm
At least 15cm
At least 300cm
Space to the ceiling
Space to the obstruction
At least 15cm
At least 15cm
Space to the wall
Space to the wall
Page 22
19
To ensure safety, please be mindful of the following precautions.
Warning
When installing or relocating the unit, be sure to keep the refrigerant circuit free from air or substances other than the specified refrigerant.
Any presence of air or other foreign substance in the refrigerant circuit will cause system pressure rise or compressor rupture, resulting in injury.
When installing or moving this unit, do not charge the refrigerant which is not comply with that on the nameplate or unqualified refrigerant.
Otherwise, it may cause abnormal operation, wrong action, mechanical malfunction or even series safety accident.
When refrigerant needs to be recovered during relocating or repairing the unit, be sure that the unit is running in cooling mode.Then, fully close the valve at high pressure side (liquid valve).About 30-40 seconds later, fully close the valve at low pressure side (gas valve), immediately stop the unit and disconnect power. Please note that the time for refrigerant recovery should not exceed 1 minute.
If refrigerant recovery takes too much time, air may be sucked in and cause pressure rise or compressor rupture, resulting in injury.
During refrigerant recovery, make sure that liquid valve and gas valve are fully closed and power is disconnected before detaching the connection pipe.
If compressor starts running when stop valve is open and connection pipe is not yet connected, air will be sucked in and cause pressure rise or compressor rupture, resulting in injury.
When installing the unit, make sure that connection pipe is securely connected before the compressor starts running.
If compressor starts running when stop valve is open and connection pipe is not yet connected, air will be sucked in and cause pressure rise or compressor rupture, resulting in injury.
Prohibit installing the unit at the place where there may be leaked corrosive gas or flammable gas.
If there leaked gas around the unit, it may cause explosion and other accidents.
Do not use extension cords for electrical connections. If the electric wire is not long enough, please contact a local service center authorized and ask for a proper electric wire.
Poor connections may lead to electric shock or fire.
Use the specified types of wires for electrical connections between the indoor and outdoor units. Firmly clamp the wires so that their terminals receive no external stresses.
Electric wires with insufficient capacity, wrong wire connections and insecure wire terminals may cause electric shock or fire.
Safety precautions for installing and relocating the unit
Page 23
1. There should be no obstruction near air inlet .
2. Select a location where the condensation water can be dispersed easily and won't affect other people.
3. Select a location which is convenient to connect the outdoor unit and near the power socket.
4. Select a location which is out of reach for children.
5. The location should be able to withstand the weight of indoor unit and won't increase noise and vibration.
6. The appliance must be installed 2.5m above floor.
7. Don't install the indoor unit right above the electric appliance.
8. Please try your best to keep way from fluorescent lamp.
Basic requirement
Indoor unit
Installing the unit in the following places maycause malfunction. If it is unavoidable, please consult the local dealer:
1. The place with strong heat sources,
vapors, flammable or explosive gas
, or
volatile objects spread in the air.
2. The place with high-frequency devices (such as welding machine, medical equipment).
3. The place near coast area.
4.
The place with oil or fumes in the air.
5. The place with sulfureted gas.
6. Other places with special circumstances.
7. The appliance shall nost be installed in the laundry.
20
Selection of installation location
Tools for installation
1 Level meter 2 Screw driver 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench
7 Open-end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 12 Universal meter
13 Inner hexagon spanner 14 Measuring tape
Note:
● Please contact the local agent for installation.
Page 24
21
Requirements for electric connection
Grounding requirement
1. Must follow the electric safety regulations when installing the unit.
air switch.
3. Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
4. Properly connect the live wire, neutral wire and grounding wire of power socket.
5. Be sure to cut off the power supply before proceeding any work related to electricity and safety. For models with a power plug, make sure the plug is within reach after installation.
7. If the supply cord is damaged, it must be replaced by the manufacturer, its
8. The temperature of refrigerant circuit will be high, please keep the interconnec­ tion cable away from the copper tube.
9.
10. Appliance shall be installed, operated and stored in a room with a floor area
Please notice that the unit is filled with flammable gas R32. Inappropriate
larger than Xm .
treatment of the unit involves the risk of severe damages of people and material. Details to this refrigerant are found in chapter “refrigerant”.
2
The appliance shall be installed in accordance with national wiring regulations.
grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock.
2. The yellow-green wire in air conditioner is grounding wire, which can't be used for other purposes.
3. The grounding resistance should comply with national electric safety regulations.
4. The appliance must be positioned so that the plug is accessible.
5. An all-pole disconnection switch having a contact separation of at least 3mm in
Safety precaution
(Please refer to table "a" in section of " Safety Operation of
Inflammable Refrigerant" for Space X.)
Page 25
22
Installation of indoor unit
Step one: choosing installation location
Step two: install wall-mounting frame
rm it with the client.
1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the
plastic expansion particles in the holes.
3. Fix the wall-mounting frame on the wall with tapping screws (ST4.2X25TA) and
.
1. Choose the position of piping hole according to the direction of outlet pipe. The position of piping hole should be a little lower than the wall-mounted frame, shown as below.
Step three: open piping hole
2. Open a piping hole with the diamete
cording to actual wall-mounted plate.
Note: Please select the corresponding installation dimensional drawing ac-
r of Φ55 on the selected outlet pipe
position. In order to drain smoothly, slant the piping hole on the wall slightly downward to the outdoor side with the gradient of 5-10°.
AAD:AAB:
Left
Wall
Φ55mm
Right
Mark in the middle of it
Level meter
Rear piping hole
Wall
Space
to the
wall
above
150mm
Space
to the
wall
above
150mm
Φ55mm
Rear piping hole
Left
Wall
Φ55mm
Right
Mark in the middle of it
Level meter
Rear piping hole
Wall
Space
to the
wall
above
150mm
Space
to the
wall
above
150mm
Φ55mm
Rear piping hole
Left
Wall
Φ70mm
Right
Mark in the middle of it
Level meter
Rear piping hole
Wall
Space
to the
wall
above
150mm
Space
to the
wall
above
150mm
Φ70mm
Rear piping hole
AAE:
Page 26
nection pipe with insulating pipe, and
insulating pipe
4. Wrap the indoor pipe and joint of con-
then wrap it with tape.
torque wrench
open-end wrench
indoor pipe
pipe
union nut
Hex nut diameter Tightening torque (N
.
m)
Φ 6
Φ 9.52
Φ 12 Φ 16 Φ 19
30~40
45~55 60~65 70~75
15~20
23
1. Aim the pipe joint at the corresponding
bellmouth.
2. Pretightening the union nut with hand.
3. Adjust the torque force by referring to the following sheet. Place the open-end wrench on the pipe joint and place the torque wrench on the union nut. Tighten the union nut with torque wrench.
2. When select leading out the pipe
from left or right, please cut off the corresponding hole on the bottom case.
cut off the hole
left right
1. The pipe can be led out in the direction of right, rear right, left or rear left.
left
rear left
right
rear right
Step four: outlet pipe
Installation of indoor unit
union nutpipe joint
pipe
Note:
● Pay attention to dust prevention and take relevant safety measures when
opening the hole.
The plastic expansion particles are not provided and should be bought
locally.
Indoor
5-10°
outdoor
Φ55
Page 27
Installation of indoor unit
Outdoor unit connection
1824K:
12K:
N(1) 2 3
3. Remove the wire clip; connect the power connection wire to the wiring terminal according to the color; tighten the screw and then fix the power connection wire with wire clip.
2. Make the power connection wire go through the cable-cross hole at the back of indoor unit and then pull it out from the front side.
1. Connect the drain hose to the outlet pipe of
outlet
pipe
drain hose
drain hose
tape
outlet pipe
drain hose
insulating pipe
Add insulating pipe in the indoor
The plastic expansion particles are
1. Open the panel, remove the screw on the wiring cover and then take
wiring cover
screw
panel
Step seven: connect wire of indoor unit
Step six: install drain hose
indoor unit.
2. Bind the joint with tape.
Note:
drain hose in order to prevent condensation.
not provided.
down the cover.
24
yellow­green
blue black brown
Outdoor unit connection
N(1) 2 3
yellow­green
blue black brown
09
Page 28
Installation of indoor unit
Step eight: bind up pipe
1. Bind up the connection pipe, power cord and drain hose with the band.
indoor unit
gas pipe
indoor and
outdoor power cord
liquid pipe
drain hose
band
2. Reserve a certain length of drain hose and power cord for installation when binding them. When binding to a certain degree, separate the indoor power and then separate the drain hose.
3. Bind them evenly.
4. The liquid pipe and gas pipe should be bound separately at the end.
Note:
The power cord and control wire can't be crossed or winding.
The drain hose should be bound at the bottom.
drain hose
band
connection pipe
indoor power cord
25
4. Put wiring cover back and then tighten the screw.
5. Close the panel. Note:
All wires of indoor unit and outdoor unit should be connected by a professional.
for a new one. Avoid extending the wire by yourself.
installation.
● For the air conditioner without plug, an air switch must be installed in the line. The air switch should be all-pole parting and the contact parting distance should
be more than 3mm.
Page 29
Step nine: hang the indoor unit
1. Put the bound pipes in the wall pipe and then make them pass through the wall hole.
2. Hang the indoor unit on the wall-mounting frame.
3. Stuff the gap between pipes and wall hole with sealing gum.
4. Fix the wall pipe.
5. Check if the indoor unit is installed firmly and closed to the wall.
Note:
● Do not bend the drain hose too excessively in order to prevent blocking.
indoor
outdoor
wall pipe
sealing gum
upper hook
lower hook of wall-mounting frame
Installation of indoor unit
26
Page 30
27
Check after installation
Test operation
Items to be checked Possible malfunction
The unit may drop, shake or emit noise.
Have you done the refrigerant leakage test?
(heating) capacity. It may cause condensation and water
dripping.
Is water drained well?
It may cause condensation and water dripping.
Is the voltage of power supply accord­ing to the voltage marked on the nameplate?
It may cause malfunction or damaging the parts.
Is electric wiring and pipeline installed correctly?
It may cause malfunction or damaging
the parts. Is the unit grounded securely? It may cause electric leakage. Does the power cord follow the speci-
It may cause malfunction or damaging
the parts. Is there any obstruction in the air inlet
Is the inlet and outlet of piping hole been covered?
and outlet?
(heating) capacity. The dust and sundries caused during
installation are removed?
It may cause malfunction or damaging
the parts. The gas valve and liquid valve of
connection pipe are open completely?
(heating) capacit
It may cause insufficient cooling
(heating) capacity or waster eletricity.
y.
1. Preparation of test operation
The client approves the air conditioner.
● Specify the important notes for air conditioner to the client.
2. Method of test operation
● Put through the power, press ON/OFF button on the remote controller to start operation.
● Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to check whether the operation is normal or not.
● If the ambient temperature is lower than 16℃, the air conditioner can’t
start cooling.
Page 31
Page 32