1.2 Important notice for wireless operation of TOSIBOX® Lock 5
1.3 Safety and hazards 5
1. Informations réglementaires 6
1.1 Utilisation prévue de TOSIBOX® Lock 6
1.2 Avis important concernant le Fonctionnement
sans fil du TOSIBOX® Lock 6
1.3 Sécurité et dangers 7
2. Overview to TOSIBOX® Key and Locks 8
2.1 TOSIBOX® Key 6
2.2 TOSIBOX
®
Locks 9
3. Getting started16
4. TOSIBOX
®
Lock instructions 17
4.1.1 Deploying Lock in “Lock Mode” 17
4.1.2 Deploying Lock in “Client Mode” 18
4.2 Connecting Locks 17
4.3 Updating the Lock Software 19
4.4 USB Modem settings for the Lock 20
4.5 Internal modem settings for Lock 500i 20
4.6 WLAN settings for Lock 100, Lock 150 and Lock 500 20
4.7 Key connection settings for the Lock 20
4.8 Advanced settings for the Lock 21
4.9 Internet connection priorities 21
4.10 PoE 21
4.11 Service Port 21
4.12 Mounting instructions 24
4.13 Input powering options 26
4.14 Lock 500 - Digital In/Out port with 24V DC out 28
4.15 Lock 500 - Software configurable I/O 28
4.16 Lock 500 - Digital I/O SMS alert 30
5. TOSIBOX® Key instructions 30
5.1 Taking Master Key into use 32
5.2 Renaming and using devices 34
5.3 Adding extra Keys 36
5.4 Remote matching of extra Keys 41
5.5 PUK code for the Key 41
6. TOSIBOX® Mobile Client installation 42
6.1 Mobile Client for Android Devices 42
6.2 Mobile Client for iPhones and iPads 47
7. Troubleshooting 52
7. Dépannage 52
8. Maintenance instructions 52
8. Consignes d’entretien 53
9. Technical data 54
10. Limited Warranty 63
11. Legal Notices 60
11. Mentions légales 64
12. Declarations 65
3
®
Congratulations for choosing TOSIBOX
solution! It consists of modular components
that offer unlimited expandability and flexibility. All products are compatible with
each other as well as internet connection, operator, and device agnostic. The system
works both in internal and external networks.
• TOSIBOX
• TOSIBOX
®
Key is a client used to access the network.
®
Lock is a router with firewall sharing access to devices.
In physical matching, the Key is inserted to the Lock’s USB port. The devices exchange
their security certificates (and public keys). This trust relationship is the basis for all
communication happening afterwards.
®
TOSIBOX
creates direct VPN tunnel between the physical devices. Only trusted
devices can access the network.
®
TOSIBOX
is globally audited, patented and performs at the highest security levels
in the industry. The technology is based on two-factor authentication, automatic
security updates and the latest encryption technology.
TECHNICAL SUPPORT
support@tosibox.com
FINLAND
+358 44 744 0065
Business hours:
from 8 am till 4 pm Mon – Fri (UTC+2)
GLOBAL
+358 44 738 1778
Business hours:
from 8 am till 4 pm Mon – Fri (UTC+2)
TOSIBOX HELPDESK
http://www.tosibox.com/support
HMI
TOSIBOX
Mobile
Client
®
VPN tunnel
®
TOSIBOX
Key
®
through Internet
TOSIBOX
Lock
Firewall
PLC
Camera
PC
1. REGULATORY INFORMATION
4
1.1 TOSIBOX® LOCK INTENDED USE
The Lock is used for controlling other devices remotely over the
Internet via a VPN connection. To be installed into a DIN rail, inside
a cabinet with the controlled devices. Alternatively, the Lock may
be standing on its rubber feet on a table or a shelf. The product
conformity with the requirements is guaranteed only when using
the antennas supplied with the product. The use of other antennas
will void the conformity and is not allowed.
• Lock 100/150: Office and residential environment
Norway: Use of this radio equipment (Wi-Fi) is not allowed in the
geographical area within a radius of 20 km from the centre of
Ny-Ålesund, Svalbard, Norway.
• Lock 200: Office, residential and light industrial environment
• Lock 500: Office, residential and light industrial environment
Norway: Use of this radio equipment (Wi-Fi) is not allowed in the
geographical area within a radius of 20 km from the centre of
Ny-Ålesund, Svalbard, Norway.
1.2 IMPORTANT NOTICE FOR WIRELESS OPERATION
OF TOSIBOX® LOCK
Because of the nature of wireless communications, transmission
and reception of data can never be guaranteed. Data may be
delayed, corrupted (i.e., have errors) or be totally lost. Although
significant delays or losses of data are rare when wireless devices
are used in a normal manner with a well-constructed network,
TOSIBOX® Lock with cellular modem should not be used in situations
where failure to transmit or receive data could result in damage of
any kind to the user or any other party, including but not limited to
personal injury, death, or loss of property.
Tosibox Oy and its affiliates accept no responsibility for damages
of any kind resulting from delays or errors in data transmitted or
received using TOSIBOX
of the TOSIBOX® Lock with cellular modem to transmit or receive
such data.
®
Lock with cellular modem, or for failure
1.3 SAFETY AND HAZARDS
At least 20 cm separation distance between the antennas and
persons must be maintained at all times.
Do not operate your Lock with internal or external cellular modem:
• In areas where blasting is in progress
• Where explosive atmospheres may be present including refuelling
points, fuel depots, and chemical plants
• Near medical equipment, life support equipment, or any equipment
which may be susceptible to any form of radio interference. In
such areas, the Lock and the cellular modem MUST BE POWERED
OFF. Otherwise, the cellular modem can transmit signals that could
interfere with this equipment.
• In an aircraft, the Lock and the cellular modem MUST BE POWERED
OFF. Otherwise, the Lock and the cellular modem can transmit
signals that could interfere with various onboard systems and
may be dangerous to the operation of the aircraft or disrupt the
cellular network. Use of a cellular phone in an aircraft is illegal in
some jurisdictions. Failure to observe this instruction may lead to
suspension or denial of cellular telephone services to the offender,
or legal action or both. Some airlines may permit the use of cellular
phones while the aircraft is on the ground and the door is open. The
Lock and the cellular modem may be used normally at this time.
5
1. INFORMATIONS RÉGLEMENTAIRES
6
1.1 UTILISATION PRÉVUE DE TOSIBOX® LOCK
Le verrou sert à contrôler d’autres appareils à distance via Internet via une
connexion VPN. Pour être installé sur un rail DIN, à l’intérieur d’une armoire
avec les appareils contrôlés. Sinon, la serrure peut reposer sur ses pieds
en caoutchouc sur une table ou une étagère. La conformité du produit aux
exigences n’est garantie que si vous utilisez les antennes fournies avec le produit.
L’utilisation d’autres antennes annulera la conformité et n’est pas autorisée.
• Lock 100/150: environnement de bureau et résidentiel
Norvège: l’utilisation de cet équipement radio (Wi-Fi) n’est pas
autorisée dans la zone géographique située dans un rayon de 20 km
du centre de Ny-Ålesund, Svalbard, Norvège.
• Lock 200: environnement de bureau, résidentiel et industriel léger
• Lock 500: environnement de bureau, résidentiel et industriel léger
Norvège: l’utilisation de cet équipement radio (Wi-Fi) n’est pas
autorisée dans la zone géographique située dans un rayon de 20 km
du centre de Ny-Ålesund, Svalbard, Norvège.
1.2 AVIS IMPORTANT CONCERNANT LE
FONCTIONNEMENT SANS FIL DU TOSIBOX® LOCK
En raison de la nature des communications sans fil, la transmission
et la réception de données ne peuvent jamais être garanties.
Les données peuvent être retardées, corrompues (c’est-à-dire
avoir des erreurs) ou totalement perdues. Bien que les retards
importants ou les pertes de données soient rares lorsque les
périphériques sans fil sont utilisés de manière normale avec un
réseau bien construit, TOSIBOX® Lock avec modem cellulaire ne
doit pas être utilisé dans les cas où le défaut de transmission
ou de réception des données pourrait entraîner des dommages
matériels. en nature à l’utilisateur ou à toute autre partie, y
compris, sans toutefois s’y limiter, les dommages corporels, le
décès ou la perte de biens.
Tosibox Oy et ses filiales n’acceptent aucune responsabilité
pour les dommages de quelque nature que ce soit résultant de
retards ou d’erreurs dans les données transmises ou reçues à
l’aide de TOSIBOX® Lock avec modem cellulaire, ou en cas d’échec
de TOSIBOX
recevoir ces données.
®
Lock avec modem cellulaire pour transmettre ou
1.3 SÉCURITÉ ET DANGERS
Une distance minimale de 20 cm entre les antennes et les personnes
doit être respectée à tout moment.
N’utilisez pas votre serrure avec un modem cellulaire interne ou
externe:
• Dans les zones où le dynamitage est en cours
• Où des atmosphères explosives peuvent être présentes, y compris
des points de ravitaillement en carburant, des dépôts de carburant
et des usines chimiques
• À proximité d’équipements médicaux, d’équipements de survie, ou
de tout équipement susceptible de subir toute forme d’interférence
radio. Dans ces zones, le verrou et le modem cellulaire DOIVENT
ÊTRE ÉTEINTS. Sinon, le modem cellulaire peut émettre des signaux
susceptibles d’interférer avec cet équipement.
• Dans un avion, le verrou et le modem cellulaire DOIVENT ÊTRE
ÉTEINTS. Sinon, le verrou et le modem cellulaire peuvent émettre
des signaux susceptibles de perturber le fonctionnement de divers
systèmes embarqués et de nuire au bon fonctionnement de l’avion
ou de perturber le réseau cellulaire. L’utilisation d’un téléphone
cellulaire dans un avion est illégale dans certaines juridictions. Le
non respect de cette instruction peut entraîner la suspension ou
le refus des services de téléphonie cellulaire pour le contrevenant,
ou des poursuites judiciaires, ou les deux. Certaines compagnies
aériennes peuvent autoriser l’utilisation de téléphones cellulaires
lorsque l’avion est au sol et que la porte est ouverte. Le verrou et le
modem cellulaire peuvent être utilisés normalement à ce moment.
7
2. OVERVIEW TO TOSIBOX® KEY AND LOCKS
2.1 TOSIBOX® KEY
TOSIBOX® Key is an intelligent USB-connected device that
contains a secure cryptoprocessor. The Key is used to establish
a secure connection to the Lock. All TOSIBOX® Keys and Locks are
interoperable.
SUB KEY
An additional Key that has restricted access rights.
BACKUP KEY
A duplicated backup copy of the Key. All matched Keys and Locks
are automatically synchronized between the original Key and the
Backup Key.
8
Key user interface (installed from the Key device). In the image you can see
TOSIBOX® Lock devices which are matched with the TOSIBOX® Key and the
network devices connected to each TOSIBOX® Lock.
2.2 TOSIBOX® LOCK
TOSIBOX® Lock is a device that accepts remote connections from
matched Keys and creates private and secure access to connected
network devices. The network devices that are connected to the
Lock´s LAN port are automatically found. The Lock automatically
distributes IP addresses for the Keys, Sub Keys and the network
devices connected to LAN port(s) of the Lock. The Lock can also
control network devices with fixed IP addresses.
Lock settings can be changed via service port, encrypted TOSIBOX
VPN connection local network
®
9
Lock 100/150
SUB LOCK
A Sub Lock is a Lock that has been converted to Sub Lock mode.
When connecting two Locks to each other, one must be in Sub Lock
mode of operation.
Lock 200
Lock 500/500i
10
LOCK 100/150 CONTENT
TOSIBOX® Lock 100/150
AC Adapter*
USB Cable
Ethernet Cable
* AC Adapter model is subject to change according to the market area.
DIN Rail Bracket
DC Feed Plug
Antennas (2)
LOCK 200 CONTENT
TOSIBOX® Lock 200
AC Adapter*
USB Cable
Cable Saddle
Ethernet Cable
* AC Adapter model is subject to change according to the market area.
DC Feed Plug
Rubber Feet
DIN Rail Bracket
11
LOCK 500/500i CONTENT
TOSIBOX® Lock 500/500i
(LTE ports only in Lock 500i)
LTE-Antennas*
(only Lock 500i)
Ethernet Cable
WiFi-Antennas
LOCK 500 POWER SOURCE KIT CONTENT
AC Power Source*
AC Plug Adapters
DC-Conversion Cable
Digital I/O
Connector
*) Antenna model is subject to change according to the market area.
Power
Connector
SIM Card
Slot Cover
*) AC Adapter model is subject to change according to the market area.
MODEL REGION WLAN LTE POWER KIT WLAN ANT LTE ANT
TBL5 EU/Global x x
TBL5PS EU/Global x x x
TBL5iA EU/US x x x x
TBL5iAPS EU/US x x x x x
TBL5iB APAC x x x x
TBL5iBPS APAC x x x x x
LOCK CONNECTIONS
12
LOCK 100/150
WLAN antenna ports
1. 2. 3. 4. 5. 6. 7. 8.
10. 11. 12. 13. 14. 15.
9.
1. USB Port for matching
and USB Modem
2. WAN Port
3. LAN1 Port
4. LAN2 Port
5. LAN3 Port
6. Service port
7. Reset button (not in use)
8. DC Power Input
Led indicators:
9. Power
10. WLAN
11. Service
12. LAN3
13. LAN2
14. LAN1
15. WAN
LOCK 200
13
1. DC Power Input
2. Reset button (not in use)
3. Power led indicator
9.
8.
7.
6.
5.
4.
3.
2.
1.
4. Info led indicator
5. WAN Port
6. Service Port
7. LAN1 Port
8. LAN2 Port
9. LAN3 Port
USB Port for matching and USB
Modem
LOCK 500/500i
14
1.
2.
3.
4.
6.
5.
8.
7.
9.
* LAN3 Port can be configured as a Service Port
1. SIM card slot
2. USB Port for matching
and USB Modem
3. Reset button for Service
Port activation only
4. Digital I/O -Connection
10.
14.
15.
16.
17.
LED indicators:
14. Power
15. Internet
16. WiFi
17. LTE
Ethernet Connections:
11.
6. WAN Port
7. LAN3 Port*
5. LAN2 Port
12.
8. LAN1 Port
9. Power Connection
13.
10. WiFi Antenna Port 1
18.
19.
Ethernet Port Leds:
18. LAN2
20.
21.
19. WAN
20. LAN3
21. LAN1
11. LTE Antenna Port 2
(Lock 500i only)
12. WiFi Antenna Port 2
13. LTE Antenna Port 1
(Lock 500i only)
LOCK USER INTERFACE
15
Status bar shows
general information.
Locks and Keys
Green: Connected
Red: Disconnected
Remotely controlled
devices
Green: Connected
Red: Disconnected
Details of the remotely
controlled devices
Login using “admin”
user.
Password can be
found on the bottom of
the Lock
3. GETTING STARTED
THE FIRST DEPLOYMENT
1. Make sure the Lock is powered before
proceeding to matching the Key with the Lock.
Insert the Key into the USB port of the Lock.
When the LED on the Key turns off, the matching
is complete (approximately 10 seconds). Remove
the Key from the Lock. You can also match
additional Locks to the same Key.
2 - 3. Connect the Lock to your network according to
your use case. Remember to make sure that the
Lock has a working internet connection.
4. Connect the Key to your computer and install the
Key software. Follow the section ”Deploying the
Key”.
5. Secure TOSIBOX
be used for controlling and monitoring devices
remotely.
®
connection is now ready to
1.
3.
5.
16
2.
4.
4. TOSIBOX® LOCK INSTRUCTIONS
17
4.1.1 DEPLOYING LOCK IN “LOCK MODE”
HMI
®
TOSIBOX
Lock
Firewall
TOSIBOX
Mobile
Client
VPN tunnel
®
TOSIBOX
Key
®
through Internet
With its factory default settings, the Lock is connected to the
Internet via its WAN port or a USB modem which can be connected
to the USB port of the Lock. In this mode, the Lock creates its
own protected local network for the connected devices. In this
configuration, only devices that are connected to the Lock by cable
or via WLAN access point are accessible with the Key.
Note:
• See “USB Modem settings for the Lock” (page 18) to connect a USB modem to
the Lock’s USB port.
• If the Lock is connected to a DHCP enabled network via any of its LAN ports
(LAN1, LAN2 or LAN3) the Lock’s own LAN functionality can be restored by
resolving any DHCP conflicts by removing improper LAN connections to the
Lock.
CONNECTING NETWORK DEVICES TO THE LOCK
A) Connecting device(s) that use dynamic IP addresses (DHCP)
Devices with a DHCP client enabled will automatically connect to the
Lock. Plug the device(s) into the Lock’s LAN port(s) and go!
B) Connecting device(s) with Fixed IP addresses by configuring
the DEVICE to the LOCK:
PLC
Camera
PC
1. Before connecting device to Lock, connect to device per device
manufacturer’s instructions on your PC and assign a new static
IP address to device(s) from the Lock’s IP range printed on
the bottom label of the Lock. Do not add same IP address. We
recommend adding the next IP sequential address ABOVE the IP
address on the lock, and so forth for each additional device. (*Note:
Lock’s IP and netmask address can also be found in the service port
at Network > LAN)
2. Plug the device(s) into the Lock’s LAN port(s) and go!
C) Connecting device(s) with Fixed IP addresses by configuring
the LOCK to the DEVICE:
1. Get the device(s’) IP address(es) and netmask.
2. Connect your PC to the Lock’s service port and log in following the
step 1 on page 17 “Updating the Lock software”.
3. Go to Network->LAN and change the IP address in the “IPv4
address” field to the next IP address above the IP address of
the device (step 1). Also check that the “IPv4 netmask” field
corresponds to the netmask set on the device and change it if
necessary.
4. Plug the device(s) into the Lock’s LAN port(s) and go!
5. ADVANCED/ENTERPRISE USERS ONLY: Go to Network>LAN DHCP
SERVER and set the “Start” value so that it’s higher than all used
static addresses. Set the limit value to a suitable value so that it
covers the rest of the unused addresses in the LAN range. For
example, the range 192.168.5.50 – 192.168.5.254 contains 205
addresses so the “Start” value would be 50 and the “Limit”value
would be 205.
18
4.1.2 DEPLOYING LOCK IN “CLIENT MODE”
Client mode can be used for connecting the Lock to an existing
network (e.g. an office network). In this mode, the Lock joins the
network like any other device (e.g. a PC) and provides remote
users with access to other devices in the same network. The Lock
will obtain its address from the DHCP, so the local network needs
to have a working DHCP server that allocated IP addresses.
A) Connecting network devices in Client Mode
1. Log into the Lock’s web user interface as admin and open the LAN
settings by clicking Network > LAN.
2. Change the LAN interface protocol field to “DHCP Client”. Click the
“Switch Protocol” button and click “Save”.
3. Plug in a cable from the local network into one of the Lock’s LAN
ports and go!
PC
TOSIBOX
Key
VPN tunnel
®
through Internet
Note:
• Do not connect the internet to the Lock’s WAN Port or a USB modem to the
USB port. Doing so will automatically deactivate the client mode and revert the
Lock’s LAN settings back to factory defaults.
• Do not connect any LAN port directly to the internet.
• Do no connect the controlled devices to any LAN port.
• The lock will scan the entire LAN network for connected devices and will grant
device access to any user with a matched Key. Please keep this in mind when
considering network and information security.
• In cases where access rights need to be restricted, switch on MAC/IP
Filtering (under Advanced Settings) or set up the Lock in its factory default
configuration.
• In this mode, the Lock’s inbuilt firewall does not protect the devices in the LAN
network.
• Client Mode is deactivated from the Lock’s web user interface
PC
Server
Router
L
A
N
PC/Laptop
TOSIBOX
Lock
Printer
®
4.2 CONNECTING LOCKS
With TOSIBOX® Locks one can connect machines in separate
places so that the connection between them is permanently and
automatically on. One example is a real-time protected connection
between home and office. This is made with a Lock/Sub Lock
solution (see accompanying image Connecting Locks). To Lock 100
and Lock 150 can be connected to up to 10 Sub Locks, to Lock 200
and Lock 500 can be connected to up to 50 Sub Locks.
First match the Key to all the Locks to be connected as described
in section “Instructions for TOSIBOX
CONNECTING LOCKS
1. Insert a matched Key to the USB port of the computer.
2. Choose ”Devices” from the Key user menu and ”Connect Locks”
from the drop down menu.
3. Choose the Locks that you want to connect together and choose
”Next”.
4. Choose the Lock that you want to attach the Sub Locks. The other
Locks will be changed to Sub Lock operating mode.
5. Confirm the selection > Save > matching is ready.
Note: The connections will come into effect when the Locks have
access to the Internet.
The Sub Lock ends of the connection in the picture do not have
their own DHCP service. If the connection between the Lock and
the Sub Lock is interrupted, the network devices connected with
the Sub Lock can no longer connect to the Internet and each other.
®
Key and Lock setup”.
19
Lock
Sub LockSub LockSub Lock
SublockSublockSublock
4.3 UPDATING THE LOCK SOFTWARE
1. a. Connect the computer to the service port of the Lock with
an ethernet cable. First check that you have access to the
Internet via the service port. Open an internet browser and type
http://172.17.17.17 into the address field to access the Lock user
interface. Do not type “www” before the “http://” in the address.
b. Alternatively you can also log in remotely. When the connection
between the Key and the Lock is active, double click the Lock symbol
in the Key user interface.
2. Log in using “admin” for the user ID. The default admin password is
visible on the bottom of the Lock.
20
3. Choose “Settings” > “Software update”. If there is a software
update available for the Lock, you can start the update by clicking
the “Start software update” button.
4. Wait until the update has been downloaded and installed. Do not
interrupt the power of the Lock during the software update
process. The update is complete when the software gives a notice
“Software updated successfully”.
Automatic software updates are activated as a default setting.
You can select the time when the automatic update of the released
software is allowed. You can deactivate the automatic software
update from the Lock user interface.
You can connect the Lock to the Internet with a USB Modem. For
information on supported modems go to:
http://www.tosibox.com/support.
1. Log in as admin user, select “Network” > “USB Modem”.
2. Either use the Automatic APN setting or fill in the APN and if
necessary the PIN field according to the SIM card settings. For APN
settings information, please contact your mobile operator.
3. Confirm the selection > Save.
4. Connect a Tosibox supported USB Modem to the USB port of the
Lock.
4.5 INTERNAL MODEM SETTINGS FOR LOCK 500I
You can connect the Lock to the Internet with an internal Modem.
Before inserting or removing the SIM card(s), disconnect the Lock
power supply.
1. Log in as admin user, select “Network” > “Internal Modem”
2. Either use the Automatic APN setting or fill in the APN and if necessary
the PIN field according to the SIM card settings. For APN settings
information, please contact your mobile operator.
Note: when using an older SIM card (non-USIM) the PIN code has to be
disabled before putting the SIM into the Lock 500 SIM slot. Setting PIN
code for non-USIM cards is not supported.
3. Confirm the selection > Save.
4.6 WLAN SETTINGS FOR LOCK 100, LOCK 150
AND LOCK 500
On Lock 100, Lock 150 and Lock 500 you can configure the WLAN as
Client (providing Internet access for the Lock) or as Access Point
(providing access to Lock LAN and Internet for wireless devices). For
detailed set-up instructions visit http://www.tosibox.com/support.
4.7 KEY CONNECTION SETTINGS FOR THE LOCK
You can change the Key connection type from Layer 3 -routed
(default) to Layer 2 -bridged (“Connection type” > “Layer 2-bridged”).
On Layer 2 connections you can allow connections from Lock to Key.
Log into the Lock as admin, select “Settings” > “Keys and Locks” >
remove selection “Deny access towards client”
21
For more details on Layer 2 and Layer 3 connections visit
http://www.tosibox.com/support.
4.8 ADVANCED SETTINGS FOR THE LOCK
On the Advanced settings page you can configure LAN and Internet
access restrictions and security related settings.
1. Log in as admin
2. Choose “Settings” > “Advanced settings”
3. Confirm changes > Save
4.9 INTERNET CONNECTION PRIORITIES
Several alternative Internet connections can be used by the Lock:
1. WAN
2. USB modem
3. WLAN (Lock 100, Lock 150 and Lock 500 only)
4. Internal modem (Lock 500i only)
One of the available connections can be selected as a main
connection and the other connections can be set as backup
connections. In the event that the main connection is interrupted,
the connection is automatically shifted to preselected backup
connections according to the priority setting (eg. WAN port > USB
Modem). The connection is switched back to the main connection
once it is available again.
4.10 POE
(LOCK 200 ONLY)
The “PoE out” port supports PoE output, with auto detection
feature. This means you can connect laptops and other non-PoE
devices without damaging them. The PoE on “PoE out” outputs
approximately 2V below input voltage and supports up to 0.58A (So
e.g. 24V PSU will provide 22V/0.58A output to the “PoE out” port).
The device accepts powering from the power jack or from the “PoE
in” port (passive PoE)
1. DC power jack (5.5mm outside and 2mm inside diameter, female
center pin positive) accepts 8-27V DC +/-10%
2. The “PoE in” port accepts passive Power over Ethernet 8-27V DC
+/-10%
Under maximum load, the power consumption of this device is 7W.
4.11 SERVICE PORT
On Lock 100, Lock 150 and Lock 200 a dedicated Service Port is
available. On Lock 500, LAN3 port can be configured as Service
port by pressing the reset button for 3 seconds when there is
no cable in LAN3. When completed, the Internet status LED will
blink for three seconds. Lock Management Interface can then be
accessed by entering http://172.17.17.17 on the address bar of
your browser. Assigning the port back to LAN range can be done
following the same procedure or by restarting the device.
Loading...
+ 49 hidden pages
You need points to download manuals.
1 point = 1 manual.