1 Introduction
This document is a DICOM Conformance Statement for Toshiba's Digital Fluorography
Systems. It is intended to provide the reader with the knowledge of how to integrate this product
within DICOM compliant equipments. It details the DICOM Service Classes, Information
Objects, and Application Profiles which are supported by this product.
If the reader is unfamiliar with DICOM, it is recommended that they read the DICOM
Specification (referenced below) prior to reading this conformance statement. Also note that
this document is formatted according to the DICOM Specification, Part 2: Conformance.
1.1 References
• ACR-NEMA Digital Imaging and Communications in Medicine, DICOM V3.0.
1.2 Definitions
• Information Object Definition (IOD) - An IOD is a data model which is an abstraction of
real-world information. This data model defines the nature and attributes relevant to the
class of real-world objects represented.
• Service/Object Pair (SOP) Class - A SOP Class is defined by the union of an Information
Object Definition and a set of DIMSE Services. A DICOM Application Entity may support
one or more SOP Classes. Each SOP Class is uniquely identified by a SOP Class UID.
• SOP Instance - A specific occurrence of a Information Object.
• Transfer Syntax - The Transfer Syntax is a set of encoding rules that allow DICOM
Application Entities to negotiate the encoding techniques (e.g. data element structure, byte
ordering, compression) they are able to support.
• Unique Identifier(UID) - A Unique Identifier is a globally unique, ISO compliant,
ASCII-numeric string. It guarantees uniqueness across multiple countries, sites, vendors
and equipment.
- 1 -
No. MIIXR0002EAC
1.3 Acronyms, Abbreviations and Symbols
• ACC American College of Cardiology
• ACR American College of Radiology
• ASCII American Standard Code for Information Interchange
• AE Application Entity
• ANSI American National Standards Institute
• AP Application Profile
• CEN TC251 Comite Europeen de Normalisation - Technical Committee 251 - Medical
Informatics
• DICOM Digital Imaging and Communications in Medicine
• FSC File-set Creator
• FSR File-set Reader
• FSU File-set Updater
• IOD Information Object Definition
• ISO International Standards Organization
• JIRA Japan Industries Association of Radiological Systems
• NEMA National Electrical Manufacturers Association
• RWA Real-World Activity
• SOP Service-Object Pair
• UID Unique Identifier
- 2 -
2 Implementation Model
2.1 Application Data Flow Diagram
No. MIIXR0002EAC
Transfer of
X-ray
Examination
Review of
X-ray
Examination
DICOM
Recording
CD-R
Medium
DICOM
Reader
Legend
Application Entity
Local Real-World Activity
File-set Creator (FSC)
File-set Reader (FSR)
Local Relationship
Figure 1
2.2 Functional Definitions of AE's
2.2.1 DICOM Recording
The DICOM Recording supports the following tasks:
• Builds DICOM XA Information Objects.
• Creates a DICOMDIR file that represents the contents of DICOM XA Information
Objects to be recorded.
• Records DICOM XA Information Objects and DICOMDIR from the local storage to
the CD-R media.
• Duplicates the File-set of the CD-R media or the local storage onto the blank CD-R
media.
- 3 -