FILE NO. SVM-18043
CONTENTS
SAFETY CAUTION ....................................................................................................... 3
1.
SPECIFICATIONS ..........................................................................................................17
1-
1. Outdoor Unit ........................................................................................................................................17
1-
2. Operation Characteristic Curve ...........................................................................................................19
2.
CONSTRUCTION VIEWS (EXTERNAL VIEWS) .......................................................... 21
2-
1. RAV-
GM561AT*P*, GM801AT*P* .................................................................................................. 21
2-
2. RAV-
GM1101AT*P*, GM1401AT*P* .............................................................................................. 22
3.
SYSTEMATIC REFRIGERATING CYCLE DIAGRAM .................................................. 24
3-
1. Indoor Unit .......................................................................................................................................... 24
3-
2. Outdoor Unit ....................................................................................................................................... 25
4.
WIRING DIAGRAM ....................................................................................................... 28
4-
1. RAV-GM561AT*P*, GM801AT*P* ................................................................................................... 28
4-
2. RAV-GM1101AT*P*, GM1401AT*P* ............................................................................................... 29
5.
SPECIFICATIONS OF ELECTRICAL PARTS .............................................................. 30
6.
REFRIGERANT R32.................................................................
.....................................
31
6-
1. Safety During Installation/Servicing .................................................................................................... 31
6-
2. Refrigerant Piping Installation ............................................................................................................. 31
6-
3. Tools ................................................................................................................................................... 35
6-
4. Recharging of Refrigerant ................................................................................................................... 35
6-
5. Brazing of Pipes .................................................................................................................................. 36
6-
6. Instructions for Re-use Piping of R410A or R
22 ................................................................................. 3
8
6-
7. Replenishing refrigerant ...................................................................................................................... 40
7.
OUTDOOR CONTROL CIRCUIT ................................................................................... 4
2
7-
1. Outline of Main Controls ...................................................................................................................... 42
7-
2. Outdoor Print Circuit Board ................................................................................................................. 47
8.
TROUBLESHOOTING ................................................................................................... 49
8-
1. Summary of Troubleshooting .............................................................................................................. 49
8-
2. Troubleshooting .................................................................................................................................. 51
8-
3. Table Inspection of outdoor unit main parts ........................................................................................ 74
9.
SETUP AT LOCAL SITE AND OTHERS ....................................................................... 75
9-1. Calling of Error History ........................................................................................................................ 75
9-2. Group Control Operation ..................................................................................................................... 75
9-3. Outdoor Unit ........................................................................................................................................ 77
9-4. Applicable Control of Outdoor Unit ...................................................................................................... 86
10.
ADDRESS SETUP ......................................................................................................... 87
10-
1. Address Setup Procedure ................................................................................................................. 87
10-
2. Address Setup & Group Control ........................................................................................................ 88
10-
3. Remote Controller Wiring .................................................................................................................. 91
10-
4. Address Setup (Manual setting from remote controller) .................................................................... 91
10-
5. Confirmation of Indoor Unit No. Position ........................................................................................... 92
11.
REPLACEMENT OF THE SERVICE P.C. BOARD ....................................................... 94
12.
HOW TO EXCHANGE COMPRESSOR ......................................................................... 95
12-1. Exchanging Procedure of Compressor (Outline) .............................................................................. 95
12-2. Exchange of Compressor .................................................................................................................. 95
13.
DETACHMENTS ............................................................................................................ 96
13-
1. RAV-GM561AT*P*, GM801AT*P* ................................................................................................. 96
13-
2. RAV-GM1101AT*P*, GM1401AT*P* ........................................................................................... 104
14.
EXPLODED VIEWS AND PARTS LIST ....................................................................... 114
14-
1. RAV-GM561ATP-E, GM561ATJP-E, GM561ATP-TR ..................................................................... 114
14-
2. RAV-GM801ATP-E, GM801ATJP-E, GM801ATP-TR ..................................................................... 118
14-3. RAV-GM1101ATP-E, GM1101ATJP-E, GM1101ATP-TR
RAV-GM1401ATP-E, GM1401ATPJ-E, GM1401ATP-TR ............................................................... 122
Original instruction Adoption of R32 Refrigerant
This air conditioner adopts the HFC refrigerant (R32) which does not
destroy the ozone layer.
This outdoor unit is designed exclusively for use with R32 refrigerant. Be sure to
use in combination
with a R32 refrigerant indoor unit.