SERVICE MANUAL
AIR CONDITIONER
SPLIT TYPE
2 WAY CASSETTE TYPE
RAV-133TU-PE/RAV-132A-PE
RAV-163TU-PE/RAV-182A-PE
FILE No. A90-9612
Printed in UK Dec 1996
s
CONTENTS
1. SPECIFICATION........................................................................................................................................3
2. CONSTRUCTION VIEWS.........................................................................................................................5
3. WIRING DIAGRAM.....................................................................................................................................7
4. SPECIFICATIONS OF ELECTRICAL PARTS...........................................................................................9
5. INTERFACE PCB......................................................................................................................................11
6. REFRIGERANT PIPING DIAGRAM...........................................................................................................12
7. PERFORMANCE CHARACTER...............................................................................................................13
8. EXPLODED VIEWS AND PARTS LISTS..................................................................................................15
SUMMARY
• The units referred to within this manual conform with the protection requirements of Directives 89/336/EEC
Electromagnetic Compatibility and 73/23/EEC Low Voltage.
• Operating conditions of units are as follows:
OUTDOOR TEMPERATURE -2 TO 43°C
ROOM TEMPERATURE 18 TO 32°C
ROOM HUMIDITY LESS THAN 80%
Note 1 : Cooling Capacity is based on the following temperature conditions:
Indoor air inlet temperature 27°C DB, 19°C WB.
Outdoor air inlet temperature 35°C DB.
Note 2: For details on the Remote Controller and Control Circuits
refer to Service Manual A90-9504.
-2-
1. SPECIFICATIONS
ITEM
Cooling capacity kW
Power source
Power consumption
Power factor
Running current
Starting current
Operating noise (SPL)
Refrigerant
Refrigerant control
Interconnection pipe
Condensate drain pipe diameter mm
INDOOR UNIT Model RAV-133TU-PE
Appearance colour Grey (zinc galvanized steel + thermal insulator)
Dimensions
Net weight kg 23
Heat exchanger type
Indoor fan type Transverse flow fan
Air volume m3/h 700
Fan motor output
Air filter
OUTDOOR UNIT Model RAV-132A-PE
Appearance colour Bronze white (Munsell 6Y7.5/1)
Dimensions
Net weight kg 58
Heat exchanger type
Outdoor fan type
Air flow volume m3/h 2,700
Fan motor output
Compressor
Protective device
CEILING PANEL Model
Appearance colour Silky white (Munsell 2.9Y8.9/0.8)
Dimensions
Net weight
Air filter
Indoor unit (High, Med, Low)
Outdoor unit
Name of refrigerant
Charge volume
Add. volume (20-30m)
Larger side size
Coupler style
Smaller side size
Coupler style
Standard length
Maximum length
(of one way) *1 m
Maximum height difference
If indoor unit higher m 15
If outdoor unit higher m 30
Height mm 190
Width
Depth mm 480
Height mm
Width
Depth mm
Model
Output
Height mm
Width mm
Depth mm
Phase
V
Hz
kW
%
A
A
dB(A)
dB(A)
kg
g/m
mm
mm
m
mm
W 7 x 2
mm
W
kW
kg
MODEL
Fuse, Crankcase heater, Overload relay
RAV-133TU-PE
3.6
1
220-240
50
COOLING
2.1
89
10.3
60
40/36/34
52
R-22
1.2
35
Capillary tube
Ø12.7 (1/2)
Flare
Ø 6.4 (1/4)
Flare
7.5
30
Ø 25.5 (OD)
910
Finned tube
Washable
740
880
310
Finned tube
Propeller fan
39
PH230X3-4LS
1.5
RBC-U133PG(W)-PE
25
1050
550
4.5
Washable
Specifications are subject to change without notice.
* Note 1 : These mean actual length.
-3-
ITEM
Cooling capacity
Power source
Power consumption kW
Power factor %
Running current A
Starting current
Operating
noise (SPL)
Refrigerant
Refrigerant control
Interconnection
pipe
Condensate drain pipe diameter ø 25.5(OD)
INDOOR UNIT Model
Appearance colour
Dimensions
Net weight kg
Heat exchanger type
Indoor fan type
Air volume
Fan motor output
Air filter
OUTDOOR UNIT Model
Appearance colour
Dimensions
Net weight
Heat exchanger type
Outdoor fan type
Air flow volume
Fan motor output
Compressor
Protective device
CEILING PANEL Model
Appearance colour
Dimensions
Net weight
Air filter
Indoor unit (high/med/low)
Outdoor unit
Name of refrigerant
Charge volume
Add. volume (20-30m) g/m
Larger side size
Coupler style
Smaller side size
Coupler style
Standard length m 7.5
Maximum length
(of one way) *1 m
Maximum height difference
If indoor unit higher
If outdoor unit higher
Height
Width
Depth mm 480
Height mm
Width
Depth mm
Model
Output
Height
Width
Depth
kW
Phase
V
Hz
A
dB (A)
dB (A)
kg
mm ø 12.7 (1/2)
mm ø 6.4 (1/4)
m
mm
mm 190
mm 910
m3/h
W
mm
kg
m3/h
W
kW
mm
mm
mm
kg
MODEL
Grey (zinc galvanized steel + thermal insulator)
Fuse, Crankcase heater, Overload relay
RAV-163TU-PE
4.5
1
220-240
50
COOLING
2.3
90
11.1
60
41/37/35
52
R-22
1.45
35
Capillary tube
Flare
Flare
30
15 m
30
RAV-163TU-PE
23
Finned tube
Transverse flow fan
750
7 x 2
Washable
RAV-182A-PE
Bronze white (Munsell 6Y7.5/1)
740
880
310
58
Finned tube
Propeller fan
2,700
39
PH250X3-4LS
1.5
RBC-U133PG(W)-PE
Silky white (Munsell 2.9Y8.9/0.8)
25
1050
550
4.5
Washable
Specifications are subject to change without notice.
* Note 1 : These mean actual length.
-4-
2.1 Indoor unit
Space required for service and installation
RAV-133TU-PE
RAV-163TU-PE
2. CONSTRUCTION VIEWS
73
20
40
110
66
90
Wiring connection
Refrigerant piping joint
( Gas ∅ 12.7)
Refrigerant piping joint
( Liquid ∅ 6.4)
186
267
170
Drain pipe joint
(outer ∅ 25.5)
Hanger bolt
(4- M10)
840
156
190
131
140
96
840
Ceiling opening 1010
Hang bolt pitch 930
Panel outer dimension 1050
40
60
40
20
25
410
Hang bolt pitch 480
Ceiling opening 510
Panel outer dimension 550
200
600
Minimum
A
1050
View A
70
480
130
290
70
190
Long hole
2-4.5 x 9L
-5-
120
83.5
550
12.5
Remote controller
600
Minimum
600
Minimum
(Unit: mm)
2.2 Outdoor unit
RAV-132A-PE
RAV-182A-PE
Knock - out hole for drain
(2-(20 x 60) slots)
Hole for drain
(2-ø19 hole)
Refrigerant piping joint
(Gas side ∅ 12.7 )
Refrigerant piping joint
(Liquid side ∅ 6.4 )
Anchor bolt hole
(4-(12x18)slots) Air outlet
Space required for service
Blow out guide
mounting hole
(4-ø3 embosses)
Carrying handle
(Both sides)
Electric parts
box
(Space for wiring
and piping)
Earth screw (M6)
Terminal cover
Outlet
(Space for wiring
and piping)
When installed with the
inlet faced to the wall side
When installed with the
outlet faced to the wall side
(Unit: mm)
-6-