BSINo. G00F059 Page 1
BSI No.: G00F059
Publish
2000/07/07
Date:
Subject: Countermeasure to JAM in ADU Entrance Area (Change of
GUIDE-STAY)
Model: DP2460, DP2570, DP3580
Category Field Application UNIT
To improve the reliability,
Change of Parts
FactoryApplication: From June 2000
To be applied when necessary ADD/ADU
CONTENT
Paper misfeeding may be caused by dew condensation. As a countermeasure, a slit hole for
prevention of dew condensation has been added and the sheet which was attached to the guide for
this purpose has been eliminated.
Sheet
Addition of a slit to the guide (The sheet has been eliminated.)
(Page 28)
BSINo. G00F059 Page 2
[Changed/Added Part No.]
MODEL P-I Before Change After Change Note P I R
DP2460
DP2570
DP2460
DP2570
DP2460
DP2570
DP3580 28-33
P-I: Page-Item P: Contents of Change I: Interchangeability R: Reasons for Change
28-33
28-42
28-43
4408668610
K-GUIDE-STAY
4401945000
SHEET-GATE-IN-F
4401945010
SHEET-GATE-IN-R
4402935260
GUIDE-STAY
4408668650
K-GUIDE-STAY
<--<---
4402958460
GUIDE-STAY
C B D Y
Elimination B D D -
Elimination B D D -
C B D Y
Attached File
Related Documents:
LinkTo: Link From: