Toshiba G00E035 Service Note

BSI No.: G00E035 Publish
2000/05/22
Date: Subject: Change of Parts of Sorter Kit (KN-FC22S01)
Model: MG2014
Category Field Application UNIT
FactoryApplication: From May at the factory (Serial No. 0041046)
CONTENT
BSINo. G00E035 Page 1
[Phenomenon]
When the sorter is pulled out from the copier (FC22), the magnet catch of the sorter may be removed from its bracket.
[Cause]
When the sorter is pulled out slantwise,
Push the holding part by the magnet. claw of the holder may be removed.
In this process, the magnet-catch is removed from the bracket.
Bracket
Claw
The holding part becomes bent. The
The holding part is removed
Magnet-catch
Bent
Magnet Holding part
[Countermeasure]
If the holding part becomes bent, a holding plate has been added the magnet catch from 1. becoming renewed. To prevent the possibility of the magnet catch coming off, the window of the bracket has been 2. made narrower.
[Changed/Added Part No.]
Claw
BSINo. G00E035 Page 2
P-I
50-21
50-23
50-24
Before Change After Change Note P I R
4400598370 BRKT-MAGNET-F 4400598400 BRKT-MAGNET-R
4400598610 BRKT-MAGNET-F 4400598630 BRKT-MAGNET-R
--- 4400598680 PLAT-MGNT-BKT-F
50-25
-- 4400598690 PLAT-MGNT-BKT-R
50-508
-- 7043300613 BID30*06MSCR1AI
P-I: Page-Item P: Contents of Change I: Interchangeability R: Reasons for Change
508
FAA
C B D -
C B D -
A - D -
A - D -
A - D -
24
P.50
Attached File
Related Documents:
LinkTo: Link From:
25
508
Loading...