Toshiba G00D017 Service Note

BSINo. G00D017 Page 1
BSI No.: G00D017 Publish
2000/04/28
Date: Subject: Instruction for 180K exchange of EPU Drum Thermistor
Model: FC22
Category Field Application UNIT
FactoryApplication: -
CONTENT
Exchange the following drum thermistor for a new one based on
P-I Part No./Name Q'ty
22-424406526540
4
180K.
ASM-THMS-DRM310
P-I: Page-Item
[Reason]
The drum thermistor of FC22 is pressed forcefully to drum side in comparison with current copiers. The sensor is protected with sliding tape and a mylar sheet. If wearing of the contact area with the thermistor is continued:
The plate spring which holds the sensor is exposed. --> The drum thermistor and the drum will
contact. --> Short with Main + 5.1V and ground --> The fuse of the power supply unit is cut. To prevent this phenomenon, be sure to exchange the drum thermistor based on 180K.
[Note]
If this phenomenon occurs: When the main switch is turned on, the "FC22 display" on the LCD does not move on to warming up. In that case check the thermistor and change the fuse based according to the following procedure.
Turn off the main switch.1. Pull out the connector J706 on the power supply unit.2. Measure the residence value of fuse ICP5 on the power supply.3.
((((open)
open)
open)open)
Confirm that Exchange the following fuse. 5.
.4.
Note)
When it is measured without J706 disconnection,
P-I Part No. Q'ty
61-1 2
P-I: Page-Item
406567710
4
FUSE-251003
((((open)
open)
open)open)
situation do not result.