Subject: Change of Fuse in Outlet Area (when installing 115V type SC-2)
Model: DP4580, DP5570, DP6570, DP8070
Category Field Application UNIT
To improve the reliability,
Change of Parts
FactoryApplication: 4/A
To be applied when necessary Other
CONTENT
When installing the SC-2, it is possible that the fuse (instantaneous interruption type 1A fuse) may
become broken in the outlet of 115V type PPC copiers. As a countermeasure, the 1A fuse has been
changed from a instantaneous interruption type to a time-lag type.
[Changed/Added Part No.]
MODEL P-I Before Change After Change Note P I R
DP4580
DP5570
DP6570
DP8070
Label display NEW61M NEWGDL
P-I: Page-Item P: Contents of Change I: Interchangeability R: Reasons for Change
[Note]
When installing the SC-2, be sure to carry out the following instructions.
Model Destination Up to and including March 2000 After April 2000
DP4580
DP5570
DP6570
DP8070
62-5A
NAD
TWD
SAD
4407010660
FUSE-1A-ULCSA
When installing the SC-2, make
sure that the fuse is exchanged.
PS)
The fuse for exchange is included
with the SC-2.
4843501266
FUSE-GDL1
NAD,TWD,SAD
(115V)
The time-lag type 1A fuse has
been already applied, so there is
no need to exchange the fuse.