Toshiba g00c967 Service Note

BSINo. G00C967 Page 1
BSI No.: G00C967 Publish
2000/03/31 Date: Subject: Correction of Double Count (08-875) <Correction: Mar. 28, 2000>
Model: FC22
Category Field Application UNIT
Correction of Service Manual
FactoryApplication: Refer to text
To be applied immediately Software
CONTENT
The two points are shown below.
The copier should be shipped with single count and double count divided by paper size, but the l single count has been set for all sizes. This error has been corrected from March at the factory.
[Changed/Added Part No.]
MODELP-I Before Change After Change Note P I R FC22
P-I: Page-Item P: Contents of Change I: Interchangeability R: Reasons for Change
1. The default of the double count has been changed from 0 to 2.
OHP/thick paper (user selection mode)
mode
Paper size
9-18 A
9-18 B
Wrong setting value in some copier at the factory was given.l
Applied serial number at the factory (BC010995)l Perform this change for the previous copiers.l In current and new, the count relationship for one sheet is shown as follows.l
4406573040 K-SRAM-T310MU00 4406573050 K-SRAM-T310ME00
Double count (08-875) OHP/thick paper double count
selection (08-858) Long Full Bleed, A3,LD
Medium B4,LG,FOLIO,COMP Short A4,A4-R,LT,LT-R,B5
B5-R,ST-R,A5,A6-R
4406574340 K-SRAM-T310MU 4406574350 K-SRAM-T310ME
Not
selected
---
NAD SAD,ASD,AUD,
MJD
Before Change After Change
Selected Not
selected
0
---
1
C B J Y
C B J Y
Selected
2
---
1 2 2 4 1 2 2 2 1 2 1 2
FAA
---Setting
1
BSINo. G00C967 Page 2
Note) If this correction is not done, the PM counter cannot be correctly counted up. So, there is a possibility that the cycle error of periodic maintenance may cause the copier failure.
An omission of this code has been found in the Service Handbook, which has been corrected as l shown in the following table.
Setting Mode (08)
Code Setting Item Default Acceptable
value
875 Double count 2 0~2
0: Single Count for all
Content Operation
order
group
1
1: Double count is used only for Long
group
2: Double count is used only for Medium
and Long group
2. The wrong setting of double count selection (08-802) in large size
Note)
The following serial number machines should be corrected to the default value (0).
Serial Number
BC010972~BC010974
08-802
2 -> 0
BC010976~BC010994
------------------------------------------------------­Mar. 28, 2000: Addition of [Changed/Added Part No.] list
Attached File
Related Documents:
LinkTo: Link From:
Loading...