Toshiba g00c964 Service Note

BSI No.: G00C964 Publish
2000/03/13 Date: Subject: ROM Version Improvement (Ver.160/Ver.13)
Model: FC22
Category Field Application UNIT Other countermeasures, Addition of the Function,
Change of Parts
FactoryApplication: From Mar. 2000
Others Software
BSINo. G00C964 Page 1
CONTENT
The ROMs version have been improved as follows.
ROM Name
SYS-ROM M-ROM IMC-ROM
Reference)
ROM Name
SCM-ROM
PMA-T310Sxx-ZZZ PRA-T310M-ZZ PRA-T310IMC-ZZ
PRA-T310SCM-10 PRA-T310SCM-11
** Only for machine made Dec.
[Changed/Added Part No.]
MODEL P-I Before Change After Change Note P I R
FC-22 8-10
8-12 A
8-12 B
8-12 C
9-17
P-I: Page-Item P: Content of Change I: Interchangeability R: Reason for Change
4406574210 PRA-T310IMC-12 4406574170 PMA-T310SUC-150 4406574180 PMA-T310SEU-150 4406574190 PMA-T310SX-150 4406574200 PRA-T310M-12
Before
Change
150 12 12
*T310SCM0320 T310SCM0321 (08-904)
4406574260 PRA-T310IMC-13 4406574280 PMA-T310SUC-160 4406574290 PMA-T310SEU-160 4406574300 PMA-T310SX-160 4406574250 PRA-T310M-13
After
Change
160 13 13
Version
New Version
T310Sxx160 (08-900) T310M1301 (08-902) T310IMC1300 (08-903)
C B B
NAD
MJD
AUD, ASD, SAD
C B B
C B B
C B B
C B B
FAA
Y Y Y Y Y
[Notes]
Be sure to carry out simultaneous exchange for SIC-ROM, M-ROM and IMC-ROM.1.
BSINo. G00C964 Page 2
When Ver.160 of SYS-ROM/Ver.13 of M-ROM/IMC-ROM is changed, be sure to perform [Work 2.
after ROMs change].
[Work after ROMs change]
Carry out the following procedure after changing ROMs.
1. Initialization of image parameters *Note1 (1) [1] +[3]+[POWER] : While pressing keys [1] and [3] simultaneously, turn on the main switch. (2) Wait about 20 seconds. The main switch is turned off when the following messages appear on the LCD.
"Initialized image parameters. Please turn off and on the copier. Thank you."
2. Initialization of image quality control Please refer to "3. Image Quality Control Adjustment" on the "26 ADJUSTMENT" page of the unpacking instructions for the FC22. (1) [0] +[5]+[POWER] (2) Key in code "879" and press the START key. Wait about 3 minutes.
3. Automatic Calibration of Gradation Please refer to "4. Automatic Calibration of Gradation" on the "26 ADJUSTMENT" page of the Unpacking Instructions for the FC22. (1) Select the cassette of A3 (or LD) sized paper. (2) [For TEXT and MAP modes]
a. Key in code "4", then press the SETTING key. The test chart is output. b. Set the test chart on the original glass. c. Key in code "643" and press the START key. Wait a few seconds. d. Press the "2" key, the START key and INTERRUPT key in that order. e. After the message "SCAN COMPLETED" appears, press the START key. f. After the message "COMPLETED" appears, press the STOP key.
(3) [For PHOTO made]
a. Key in code "5", then press the SETTING key. The test chart is output. b. Set the test chart on the original glass. c. Key in code "643" and press the START key. Wait a few seconds. d. Press "3" key, the START key and INTERRUPT key in that order. e. After the message "SCAN COMPLETED" appears, press the START key. f. After the message "COMPLETED" appears, press the STOP key.
4. Turn off the main switch. *Note1 Initialization of image parameters
When initialization of the image parameters is performed, the following adjustment value will be changed to the initial value. Please readjust if needed. Please refer to page 1-73 from page 1-69 in the Service Handbook. 1-8. Density Adjustment (08/550-589) 1-9. Color Balance Adjustment (08/779-798) 1-10. Offset Amount for Processing Background (08/698/717) 1-11. Judgment Threshold for ACS (08/675) 1-12. AI Mode Setting (08/678, 682) 1-13. Sharpness Adjustment (08/730-745)
[Contents of Change]
SYS-ROMl
[150 --> 160]
1. To improve the image, the contrast and sharpness parameter of TEXT/PHOTO mode have been
changed.
2. When either of LCF, each cassette or ADU has broken down, if this broken paper feeding device is
Loading...
+ 1 hidden pages