BSI No.: F99L902
Publish
99/12/24
Date:
Subject: Change of IR Unit (Scanner)
Model: FC70
Category Field Application UNIT
Other Others Optical
FactoryApplication: Service parts (Not applied to machines made)
CONTENT
The part change has been made for the following reasons.
[Changed/Added Part No.]
Refer to
No.
01 4-9
P-I: Page-Item P: Content of Change I: Interchangeability R: Reason for Change
[Changed Reason and Contents]
In the scanner area, there is a possibility that connection cord clamp and the main reflector on the
bracket (01) may contact. To prevent this, installation hole has been changed and the shape of the
short cord clamp has been altered. So, though the cord clamp has been changed from P.53 item No."
14" in the Parts List to "118", be sure to exchange the bracket at the same time.
P-I Before Change After Change Note P I R
4402404980
BRACKET
4401922710
BRACKET
---- C D J -
FAA
Main reflector
Attached File
Related Documents:
Cord clamp
Installation hole