Error during Image Input
MODEL
CATEGORY
Treatment in the field
----
CONTENT
[Phenomenon] When a FAX original is to be sent, due to the combination of the scanner secondary scanning reproduction ratio, the original size and the resolution, "Not allowed now" is indicated after the original scanning. It may not be sent.
DP2570
FIELD APPLICATION
To be applied when necessary
FACTORY APPLICATION
Date
UNIT
Software
99/11/18
----
[Error Reason] The conditions of use do not match those for the image compressor LSI.
[Countermeasure] The setting value of self-diagnosis is 08 mode code "453" "Correction of the magnification scanning line" should be changed to "0" (Not functional) when the above occurs.