Toshiba f99k840 Service Note

BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F99K840
Weekly Timer
MODEL
CATEGORY
Other countermeasures
-
CONTENT
When the weekly timer is operated at the default value of the OFF time, the power supply may cut itself off after it has been left for five minutes. This error has been caused due to setting of 0:00 as the default value of the OFF time. As a countermeasure, the default value of the OFF time has been changed to 24:00 from November at the factory.
DP4580, DP5570, DP6570
FIELD APPLICATION
To be applied when necessary
FACTORY APPLICATION
Date
UNIT
Software
99/11/10
-
Note
Be sure to check that the setting of the days of the week for which the power supply should be switched ON is not set at ON: 0:00/OFF: 0:00 in the weekly timer. If the weekly timer is used in this setting, the power supply for that the same day may be cut off after it has been left for five minutes.