BSI(Service Note)                                        TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
 F99I778
SUBJECT
  Caution When Installing K-SRAM
MODEL
CATEGORY
 Treatment in the field, 
Correction of Service Manual
 -
CONTENT
The setting value of the setting mode installed for "line adjustment" has been adjusted from "1" on the 
line to "0" at the factory. The value of the setting mode is set at K-SRAM which is installed on 
PWA-F-LGC. As the supplied part as a service part is of the same type with the inserted part on the 
line, when the K-SRAM as a service part is installed, the setting mode "08-203" must be changed at "0 
".
  DP4580, DP5570, DP6570
FIELD APPLICATION
 To be applied when necessary 
FACTORY APPLICATION
Date
UNIT
 Software
 99/09/22
-
Note
* When the setting mode "08-203 is set at "1", the copier may be not able to operate correctly. 
* Be sure to use "0" when using the copier in the field.
Service Handbook
 1.2.5 Setting mode (08)
Code Setting Item Mode Image 
Mode
203 Line adjustment 
mode
ALL 0 0 - 1 0: factory shipment
Default 
Value
Allowable 
value
Content Operation 
1: for line 
* Field: Indispensable "0" 
* When exchanging K-SRAM: 
needed check
procedure 
group
1