BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F99I772
SUBJECT
Check of Toner-Full Detection Error
MODEL
CATEGORY
Other countermeasures
From Sept. 1999 at the factory
CONTENT
If the connector of the upper feed clutch (P.8-I.15 4402235600 ASM-CLUTCH-10K) is caught
between the bracket (P.57-I.21 4406327340 HANGER-BAG-UTNR) and the metal cover (P.57-I.26
4406327460 BRKT-WALL-TNR), it is possible that toner-full detection will not be operated smoothly
and the correct amount will fail to be detected.
As a countermeasure, the wiring of the harness has been changed from September at the factory. Be
sure to carry out the following check and perform the countermeasure for machines made before.
DP4580, DP5570, DP6570
FIELD APPLICATION
To be applied when necessary
FACTORY APPLICATION
Date
UNIT
Developer
99/09/22
DTM-F9805
[Check]
1) Remove the rear cover.
2) Is the connector of the upper feed clutch being caught between
the bracket and the metal cover?
[Countermeasure]
3-1) If it is being caught
* The connector position is changed as shown below.
(Fixing is recommended with filament tape.)
* Attach the rear cover.
3-2) If it is not being caught?
* Attach the rear cover.
4) Finish
Note
Be sure to perform the same countermeasure when exchanging the
upper feed clutch.