BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F99G732
SUBJECT
Countermeasure to Dew Condensation Jamming during Duplex Copying
MODEL
CATEGORY
Other countermeasures
From Jan. 1999 (JA920087)
CONTENT
Error Content
During duplex copying, the paper misfeed may be caused in the ADU gate area because of the dew
condensation
Countermeasure
To prevent this, the sheets have been attached to the ADU gate and the transfer guide face.
DP2460
FIELD APPLICATION
To be applied when necessary
FACTORY APPLICATION
Date
UNIT
ADD/ADU
99/08/06
DTM-F8Y09
P28
[Attaching Position]
<ADU gate face>
BSI No. F99G732 Page 2
(4)
0~0.5
<Transfer guide face>
0~0.5
(6) (5)
(3)
(2)
(1)
(4)
0.5~10.5~10.5~10.5~10.5~1 0.5~1
0~0.5
K-GUIDE-STAY
0~0.5
[Changed/Added Part No.]
MODEL P-I Before Change After Change Note P I R
DP2460 28-5A
DP2460 28-42A
4401942350
K-GUIDE-OPEN
---- 4401945000
4402935280
K-GUIDE-OPEN
SHEET-GATE-IN-F
DP2460 28-43A
---- 4401945010
SHEET-GATE-IN-R
DP2460 28-44
---- 4402935350
SHEET-GUIDE-L
DP2460 28-45
---- 4402935360
SHEET-GUIDE-M
DP2460 28-46
---- 4402935390
SHEET-GUIDE-S
P-I: Page-Item P: Contents of Change I: Interchangeability R: Reasons for Change
(1) C B D Y
(2)
1 sheet
(3)
1 sheet
(4)
4 sheets
(5)
1 sheet
(6)
1 sheet
A B D Y
A B D Y
A B D Y
A B D Y
A B D Y
FAA