Toshiba f99g725 Service Note

Page 1
BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F99G725
Countermeasure to Jamming in the ADU Gate Area
MODEL
CATEGORY
Other countermeasures
From Jan. 1999 (JA920087)
CONTENT
Error Content During duplex copying, the paper misfeed may be caused in the ADU gate area because of the dew condensation
DP2460
FIELD APPLICATION
To be applied when necessary
FACTORY APPLICATION
Date
UNIT
ADD/ADU
99/08/06
DTM-F8Z02
Countermeasure To prevent this, the mylar sheet has been attached to the guide (K-GUIDE-MID-ADU) in the ADU gate area.
[Changed/Added Part No.]
MODEL P-I Before Change After Change Note P I R FAA DP2460 28-41A ---- 4402292350
K-SHEET-GUIDE
P-I: Page-Item P: Contents of Change I: Interchangeability R: Reasons for Change
A B D Y
Page 2
BSI No. F99G725 Page 2
0 ~ 0.5mm
K-GUIDE-MID-ADU 4408668760
Attaching position (see arrow A)
K-SHEET-GUIDE 4402292350
A
0 ~ 0.5mm
K-SHEET-GUIDE
Loading...