BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F99G714
SUBJECT
Change to Start Key in the Control-panel
MODEL
CATEGORY
Other countermeasures
From Dec. 1998
CONTENT
As a countermeasure, the following parts have been changed.
[Changed/Added Part No.]
Refer
to No.
P-I: Page-Item P: Contents of Change I: Interchangeability R: Reasons for Change
FC70
FIELD APPLICATION
Others
FACTORY APPLICATION
P-I Before Change After Change Note P I R FAA
01 1-34 4402429320
CONTROL PANEL
02 1-34 4402429330
CONTROL PANEL
03 70-11 4402429450
PW BOARD
04 70-12 4402429460
POLYESTER FILM
4401922290
CONTROL PANEL
4401922300
CONTROL PANEL
4401922310
PW BOARD
4401922320
POLYESTER FILM
Japan only C B D North America
only
---- C B D -
---- C B D -
Date
99/08/16
UNIT
Display Unit
1144-016-086
C B D -
[Error Content]
The Start key does not come ON.
[Cause]
In places where there is a lot of dust, the seal material has been broken when the START key has
been pressed more often than necessary. So, the adhesive material is caused to flow and dust at the
time of installation from the film hole (04) between the fixing and the driving face, which creates
insulation. The result is that START key cannot be turned ON.
[Treatment]
In order to lessen the damage to the seal material caused when the START key is pressed, the 1.
driving face of the switch on the board (03) has been changed to a flat one.
The film (04) hole has been eliminated and the dust cannot get in.2.