BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F99E626
SUBJECT
Correction of Errors in the Service Manual (Installation Instruction for the
Firmware Download and Update through "PC")
MODEL
CATEGORY
Correction of Service Manual
-
CONTENT
Errors have been found in the following Service Manual. This BSI is to provide the necessary
correction.
Service Manual:
DP-6570/5570(DIGITAL PLAIN PAPER COPIER)
DP5570, DP6570
FIELD APPLICATION
Others
FACTORY APPLICATION
Installation Instruction for the Firmware
Download and Update through "PC"
Date
UNIT
Documents
99/05/19
-
Supplement
* The corrected pages are attached as follows.
* Corrected points are shown by shaded points.
REVISION.pdf

In the case of #1 - #3:
The following screen is displayed after finished.
Firmware Version Up Mode
Target:#1
Firmware version up completed.
Target Version
1 001.002
2 002.001
3 002.031
4 003.022
5 003.022
6 003.033
Updated data version numbers
8. Press CLEAR key to cancel downloading on the way.
However, it becomes unable to cancel after start of elimination process of flash ROM.
Firmware Version Up Mode
Target: 1
Program canceled.
9. When failing in update, the following error message is displayed.
(If the error occurs, “Recovery Mode” starts automatically when you turns on the power next
time. See 10:Recovery mode)
ERROR MESSAGE
Firmware Version Up Mode
Target: 1
- file read error.
- file information error.
- unfit device.
- device erase error.
Failed to install a new firmware.
- file read error.
- device write error.
- verify error.
- cannot set NvRAM flags.
- 9 -

In the case of 1 – 6:
Message will change as follows.
Updated data version number
Change the number by pressing key
1
Firmware Version Up Mode
Target: 1
Installing a new firmware.
- reading a file.
Key
3
4
2
- reading a file.
- checking a read file.
- checking the device.
- setting NvRAM flags.
- erasing the device.
- writing to the device.
- verifying the device.
- clearing NvRAM flags.
3
Firmware Version Up Mode
Target: 1
Firmware version up completed.
Version: 001.003
> Press START key to continue.
Firmware Version Up Mode
Target: 1
> Press START key to install new
firmware.
2
Key
Ten Key
> Please select a target with DIGITAL
keys.
key
key
21
- 12 -

In the case of #1- #3:
Message will change as follows.
1’
Firmware Version Up Mode
Target:#1
Installing a new firmware.
- reading a file.
Target Version
1 installing
4’3’
Displaying current
2’
data area being
loaded
Firmware Version Up Mode
Target:#1
Firmware version up completed.
Target Version
1 001
2 002
3’
Key
- reading a file.
- checking a read file.
- checking the device.
- setting NvRAM flags.
- erasing the device.
- writing to the device.
- verifying the device.
- clearing NvRAM flags.
Updated data version numbers
2’
3 002
4 003
5 003
6 003
Power Off
Firmware Version Up Mode
Target:#1
Program canceled.
Target Version
1 001
2 canceled
Power Off
- 13 -

In the case of 1 – 6:
4
Firmware Version Up Mode
Target: 1
Failed to install a new firmware.
- file read error.
Power Off
- file read error.
- file information error.
- unfit device.
- device erase error.
- device write error.
- verify error.
- cannot set NvRAM flags.
In the case of #1 - #3:
4’
Firmware Version Up Mode
Target:#1
Failed to install a new firmware.
- file read error.
Target Version
Error
occurrence
area
Power Off
- file read error.
- file information error.
- unfit device.
- device erase error.
- device write error.
- verify error.
- cannot set NvRAM flags.
- 14 -