Toshiba f99e626 Service Note

BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F99E626
Correction of Errors in the Service Manual (Installation Instruction for the
Firmware Download and Update through "PC")
MODEL
CATEGORY
Correction of Service Manual
-
CONTENT
Errors have been found in the following Service Manual. This BSI is to provide the necessary correction. Service Manual:
DP-6570/5570(DIGITAL PLAIN PAPER COPIER)
DP5570, DP6570
FIELD APPLICATION
Others
FACTORY APPLICATION
Installation Instruction for the Firmware Download and Update through "PC"
Date
UNIT
Documents
99/05/19
-
Supplement
* The corrected pages are attached as follows. * Corrected points are shown by shaded points.
REVISION.pdf
In the case of #1 - #3: The following screen is displayed after finished.
Firmware Version Up Mode Target:#1 Firmware version up completed. Target Version 1 001.002 2 002.001 3 002.031 4 003.022 5 003.022 6 003.033
Updated data version numbers
8. Press CLEAR key to cancel downloading on the way. However, it becomes unable to cancel after start of elimination process of flash ROM.
Firmware Version Up Mode Target: 1
Program canceled.
9. When failing in update, the following error message is displayed. (If the error occurs, “Recovery Mode” starts automatically when you turns on the power next time. See 10:Recovery mode)
ERROR MESSAGE
Firmware Version Up Mode Target: 1
- file read error.
- file information error.
- unfit device.
- device erase error.
Failed to install a new firmware.
- file read error.
- device write error.
- verify error.
- cannot set NvRAM flags.