Toshiba f99e621 Service Note

BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F99E621
Cleaning of the Fuser Unit Upper Entrance Guide during Periodic
Maintenance
MODEL
CATEGORY
Treatment in the field, Correction of Service Manual
--------
CONTENT
When periodic maintenance is performed, clean the fuser unit upper entrance guide shown in this BSI. If this is not done, toner will become stuck to the fuser unit upper entrance guide edge area causing the paper to become erased and creating paper jamming. This may occur especially in copiers which make a lot of duplex copier. Since this information was not given in "Periodic Inspection Check List" in the Service Handbook, details are included in this BSI.
DP2460, DP2570
FIELD APPLICATION
Others
FACTORY APPLICATION
Date
99/05/25
UNIT
Documents, Fuser/Paper-Exit
----
Addition to Periodic Inspection Check List
Category Item to check Cleaning at
80,000 copies
Fuser
unit
Clean the capton mylar (especially, the edge) of the entrance guide. When the toner is sticking l firmly, clean by shaving it off with a ruler. When cleaning, be careful no to damage the paper transfer side (mylar leading edge).l
Fuser unit
entrance guide
(upper)
O or P
Fuser unit
Upper entrance guide
Lubricate at
80,000 copies
Replace
x 1,000
Check while onRemarks
Loading...