BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F99E616
SUBJECT
Change of Stacker ROM
MODEL
CATEGORY
Other countermeasures
From Apr. 1999
CONTENT
As a countermeasure, the following part has been changed.
[Changed/Added Part No.]
P-I Before Change After Change Note P I R FAA
27-2 4402963940
P-I: Page-Item P: Content of Change I: Interchangeability R: Reason for Change
MJ1006, MJ1007
FACTORY APPLICATION
PRA-793FIN-04
FIELD APPLICATION
Others
4402963950
PRA-793FIN-05
---- C B D Y
Date
UNIT
Finisher
99/05/25
DTM-F9407
[Label]
4F1-1051 O
1.2.3.4.5.6.
7.8.9.10.20.
[Error Content]
If the duplex 50-sheet stapling mode is performed when the AD (08) mode 652 is "1" (cascade: ON),
tray 1 stacking is full and an immediate tray change is made to tray 2, then EA6 (early arrival jam)
occurs.
[Cause/Countermeasure]
As the finisher is given a sheet clearance time (the necessary time to clear the sheets) which is
shorter than the actual time, the sheet sent to the copier exits before finisher tray has been replaced,
so an early arrival jam occurs. This BSI describes the change which has been effected to give the
sheet sufficient clearance time.
4F1-1051 O
1.2.3.4.5.6.
7.8.9.10.20.