BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F99C540
SUBJECT
Cautions Regarding Installation SG3FAX Unit (Circuit Cover)
MODEL
CATEGORY
Treatment in the field
----------
CONTENT
When installing the circuit cover of the SG3FAX (KR-6012JP1/AS1), pay attention to the following
points.
[Instruction Content]
When installing the circuit cover, it may make contact with two arresters (AR100,101) which have
been installed in the circuit modular connector on the NCU board, and the circuit cover cannot be
installed correctly. Confirm that the two arresters have fallen to the circuit modular connector side
(J100-103) in advance (refer to the details below).
DP2570, DP3580
FIELD APPLICATION
Others
FACTORY APPLICATION
UNIT
FAX
Date
99/03/12
----
Circuit cover
Knock down the arrester to the connector
montage side so what is
J100-103
Board spacer (4 pieces)
Rear cover
within 14mm
NCU board
SFX board
[Permanent Countermeasure]
The arresters (AR101,102) fell in the from the first production and were fixed. It is planned to
complete this at the factory in February 1999.