Toshiba f99a507 Service Note

BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F99A507
SUBJECT
MODEL
CATEGORY
Countermeasure to field trouble
From Feb. 1999
CONTENT
During duplex copying, condensation may be caused in the steam which occurs in the transfer guide area. To prevent a jam being caused by above phenomenon, some slits have been added to the transfer guide area
2060, 2860, 2870, 3560, 3570
FIELD APPLICATION
To be applied when necessary
FACTORY APPLICATION
Date
99/02/03
UNIT
Fuser/Paper-Exit
DTM-F8Z01
This changes applies as the permanent countermeasure for the BSI (F99A498).
[Changed/Added Part No.]
MODELP-I Before Change After Change Note P I R 2060
2860 2870 29-29
29-16
4401942390 GUIDE-STAY 4401945000
4401940590 GUIDE-STAY
-----
Addition of slit C B D Y
Elimination
SHEET-GATE-IN-F
29-30
4401945010
-----
Elimination
SHEET-GATE-IN-R
3560 3570
30-16
30-29
4401942390 GUIDE-STAY 4401945000
4401940590 GUIDE-STAY
-----
Addition of Slit
Elimination
SHEET-GATE-IN-F
30-30
4401945010
-----
Elimination
SHEET-GATE-IN-R
P-I: Page-Item P: Contents of Change I: Interchangeability R: Reasons for Change
P.29,30-16,29,30
FAA
Addition of Slit
BSI No. F99A507 Page 2
Loading...