BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F98L475
SUBJECT
Caution when Installing the Laser Unit and Addition of a Note to the Service
Manual
MODEL
CATEGORY
Treatment in the field,
Correction of Service Manual
----------
CONTENT
[Field Treatment Method]
Since an air-bearing (Not contact) is used in the polygonal motor inside the laser unit, after turning
the power supply OFF, five minutes need to pass before the laser unit is removed. (This helps to
maintain the life of the air-bearing.)
DP2570
FIELD APPLICATION
To be applied when necessary
FACTORY APPLICATION
Date
98/12/25
UNIT
Optical, Documents
----
[Addition of Note to the Manual (Note to the F98L472)]
The following note has been added to the Service Manual before "A" in "9.4 Disassembly and
replacement".
Note)
After turning the power supply OFF, five minutes need to pass before the laser
unit is removed. (This helps to maintain the life of the air-bearing.)