Toshiba f98k449 Service Note

BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F98K449
SUBJECT
MODEL
CATEGORY
Request from the field
---------
CONTENT
When the thick paper originals (especially, a large amount) are set on the ADF, they often exit irregularly. So a weight (spring) as a countermeasure to this problem has been added as a service part.
[Changed/Added Part No.]
MODEL P-I Before Change After Change Remarks P I R MR~ 4560/70
P-I: Page-Item P: Content of Change I: Interchangeability R: Reason for Change
4560, 4570, MR2008, MR3006, MR3006A
FIELD APPLICATION
To be applied when necessary
FACTORY APPLICATION
8-20 47-20
---------- 4408694680 WEIGT-SPC-099
---- A - J Y
UNIT
ADF
Date
98/12/11
DTM-F8X14
FAA
[Installation Method]
The paper-exit staple guide bar for the paper-exit under the original tray is removed. Then the current weight spring is removed once. The current and new weight springs are then installed to the paper-exit staple guide bar which is reinstalled as previously.
Current: weight (spring)
BSI No. F98K449 Page 2
Added weight (spring)
Paper-exit staple guide bar
[Notes]
With "4408694680" is installed, paper-exit misfeeding may be caused when using thin paper originals (a small amount or weak paper). * After confirming the situation of the user, the application of this BSI should be reviewed concerning what measures to take.