BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F98J412
SUBJECT
Complying with Energy-Star Tier 2 for Europe
MODEL
CATEGORY
Other countermeasures
From Aug. 1998
CONTENT
To comply with the standard values of Energy star (Tier 2) for Europe (SED, GSD, FRD, UKD), the
setting values in the setting at shipment of the Auto power save mode and the Auto shut-off mode
have been changed.
Changed Content of Setting Mode (08)
4560, 4570
FIELD APPLICATION
Others
FACTORY APPLICATION
Date
UNIT
Software
98/11/02
DTM-8508
Initial Value
Code Name Before Change After Change
AD11 auto-power-save
AD38
Heater temperature
during Auto power
0
(Functioning
after three
minutes)
8
o
(180
C)
3
(Functioning
after fifteen
minutes)
5
o
(150
C)
save
AD56 Auto shut-off
9
(Functioning
after sixty
minutes)
12
(Functioning
after ninety
minutes)
Notes)
1) The power switch is automatically turned off when the |Auto shut-off| mode is operated. Return
to the READY condition can be made by turning the power switch ON.
2) Operation time of the |Auto power save| and |Auto shut-off| modes can be extended to a
maximum of 240 minutes.
3) The power supply OFF function in the |Auto shut-off| mode has priority over the weekly timer.
Therefore, when the power supply is turned off in the |Auto shut-off| mode, the power return
function of the weekly timer cannot be operated.
4) If the setting value changes, refer to BSI/F98C249.
Also, the setting mode (08) code AD38 "Heater temperature during Auto power save" has been
omitted from the Service Manual (Service handbook). This has now been added as follows.
Code
Name Allowable
Input
Value
Initial Value Contents
BSI No. F98J412 Page 2
AD38 Heater temperature
during Auto power
save
0 ~ 11 5
0:Heater off 1:110oC 2:120oC 3:130oC
4:140oC 5:150oC 6:160oC 7:170oC
8:180oC 9:190oC 10:200oC 11:210oC
2. Applied energy-star label
An energy-star label (LBL-ENERGY-T) has been added to the front cover.
Energy-star label
[Changed/Added Part No.]
MODEL P-I Before Change After Change Destination P I R FAA
4560
4570
4560
4570
P-I: Page-Item P: Contents of Change I: Interchangeability R: Reasons for Change
8-17
1-26
4402447960
K-SRAM-T213E-S
4402447970
K-SRAM-T213EU-S
----- 4401910990
LBL-ENERGY-T
SED, GSD, FRD,
UKD
SED, GSD, FRD,
UKD
C E J Y
A E C -