BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F98I365
SUBJECT
Change of ROM/ MAIN ROM Ver. 03 -> 04
MODEL
CATEGORY
Other countermeasures
From Sept. 1998
CONTENT
The following items have been changed.
Item
A75
FIELD APPLICATION
Others
FACTORY APPLICATION
Contents
1 If the access code is too quickly inputted from the digital keys, an error may occur. To
avoid such errors, the digital keys' response has been improved.
2 If the power supply is turned ON when the toner bag is full, even if there is paper in the
cassette, an "add paper" message will be displayed. This error has been corrected.
Date
UNIT
Software
98/09/14
DTM-F8803
[ Combinations of ROM Versions ]
The MAIN, LCD and PNL should never be operated except in the following combinations. As
only the following combinations can have their operation checked, errors could well occur
with other combinations.
MAIN: Ver. 04
LCD: Ver. 010 (There is no change of the LCD ROM.)
PNL: Ver. 000 (There is no change of the PNL ROM.)
[ MAIN ROM Changed Part No. ]
MODEL
A75 64-22 4402897410
P-I: Page-ItemP: Content of Change I: Interchangeability R: Reason for Change
P-I Before Change After Change Language Machine
Region
PRA-157M-03
4402897420
PRA-157M-04
Common Common C B D Y
P I R FAA
Change History of ROM Version
Serial
Application
1997/12 WL710702
1998/3 WE811302
1998/4 WE811302
1998/9
Number
(TAD)
BL710182
(EUD)
(TAD)
-------(EUD)
(TAD)
-------(EUD)
MAIN LCD PNL
01 010
02
03
04
BSI No. F98I365 Page 2
For LanguagesFactory
Model Each
Language
000 ALL ALL F97L114 * Change of quantity of
010 000 ALL ALL F98C227 * Improvement of AC Key
010 000 ALL ALL F98E291 * Addition of MAIN SW
010 000 ALL ALL F98I365 * Improvement of access
BSI No Contents
copies able to be
stacked and stapled in
the cover/sheet insertion
mode
* Correction of jamming in
the sheet insertion mode
* Correction of poor
image visibility caused
by the automatic sort
setting value.
* Correction of editing
position adjustment
setting value
* Correction of error for
access code input at
standby.
response for access
code standby.
* Improvement of aging
mode release method
electromagnetic reset
function driving control
(ENERGY STAR Tier 2)
code response
* Correction of error
display (add paper)