BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F98H355
SUBJECT
Energy Star/ Tier 2 (Europe Region)
MODEL
CATEGORY
Safety standard Related
From Jun. 1998
CONTENT
To comply with the standard values of ENERGY STAR (Tier 2) for Europe (MJD, MFD, UKD) in the
above models, the following changes have been made.
[ Contents of Change ]
1. The initial values of the setting mode (08) which are inputted into SRAM (SRAM region: E) have
been changed.
2060, 2860
FIELD APPLICATION
Others
FACTORY APPLICATION
UNIT
Other
Date
98/09/03
DTM-F8402
Before Change
After Change
2060 2860
Auto power saving
(08-11)
Heater temperature during
power saving
(Not functioning)
(150
0
5
o
C)
11
(Functioning
after fifteen
minutes)
(Functioning
after fifteen
minutes)
No change 4
(140
11
o
C)
(08-38)
Auto shut off
(08-56)
(Not functioning)
20
6
(Functioning
after thirty
minutes)
9
(Functioning
after sixty
minutes)
Caution) Though the current SRAM (K-SRAM-T210E-S) is used for both the 2060 and the 2860
models, since the initial value is different after the change, a SRAM only for the 2860
has been newly added. So, the current SRAM is for the 2060 only.
2. Applied Energy Star label
An Energy Star label (LBL-ENERGY-T) has been added to the front cover.