BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F98G336
SUBJECT
Countermeasure to Platen Switch Detection Error
MODEL
CATEGORY
Other countermeasures,
Communalizing and
Standardizing
From Dec. 1997
CONTENT
[Phenomenon/Cause]
The platen switch (photo sensor) detects whether the platen is open or closed, but the a closed
condition has been being detected even when the white actuator has been shut. However, even when
it is shut due to sensor sensitivity, a little light has been being detected through the actuator.
2860, 2870, DP2460, KN2060S01, MP1501
FIELD APPLICATION
Others
FACTORY APPLICATION
Date
98/07/23
UNIT
Supply, Other
DTM-F7Y13
[Countermeasure]
The actuator color has been changed from white to black, and no more light should get through.
Moreover, the actuator has also been changed to the same part which is used for the LCF (MP1501)
and sorter rail kit (KN2060S01).
* If the current parts are being used, the above phenomenon does not occur in the MP1501 &
KN2060S01.
(PPC copier)
Actuator
(LCF: MP1501)
(Sorter rail kit : KN2060S01)
Actuator
BSI No. F98G336 Page 2
Actuator
[Changed/Added Part No.]
MODEL P-I Before Change After Change Note P I R FA
A
2860
2870
DP2460
MP1501
2060/2860
(KN2060S01
)
3560/3570
(KN2060S01
)
P-I: Page-Item P: Contents of Change I: Interchangeability R: Reasons for Change
5-39A 4400928890
ACTUATOR-P-SW-G
8-21
3-11
103-16
103-16
4400928890
ACTUATOR-P-SW-G
4401963190
ACTUATOR-P-SW-B
4401963190
ACTUATOR-P-SW-B
C B D C E F -