CONTENT
To comply with the standard value of ENERGY STAR (Tier 2) for Europe (EUD, GSD, FRD, SED, UKD) in the above models, the following changes have been made. Also, for conformity with other parts, some changes have been made for regions other than Europe.
5560, 6560, 7560, 7660
FIELD APPLICATION
Others
FACTORY APPLICATION
Date
98/05/27
DTM-F8110/8202/8205/8310
UNIT
Other, Software, Electrical Circuit
[ Changed Content ]
1. Setting change of Auto Power Save and Auto Shut-Off Mode at the time of shipment
Setting at the time of shipment in the above modes has been made not to permit operation but the setting values have been changed as follows.
Before Change After Change Auto energy saving (08-11) Auto shut-off (08-56)
Note) *The power switch automatically goes off when the [Auto shut-off] mode is operated.
Return to the READY condition can be made by turning the power switch ON.
* Operation time of [Auto energy saving] [Auto shut-off] can be extended to a maximum of
240 minutes.
*The power supply OFF in the [Auto shut-off] mode has priority over the Weekly Timer.
Therefore, when the power supply is turned off in the [Auto shut-off] mode, the power return function of the Weekly Timer cannot operated.
*If the setting value changes, refer to BSI/F98C249.
2. Change of power supply switch to one with an electromagnetic reset function In order to be able to reset the MAIN SW using software, change has been made to the power supply switch by giving it an electromagnetic reset function. This switch has a MAIN SW inside coil for resetting and the switch goes off when DC24V is added to the coil. The combination of the switch terminal and the harness connection has also been changed as shown below.
0
(No function)
20
(No function)
3
(Function after fifteen minutes)
12
(Function after ninety minutes)
Coil for reset
-> 1
2 <-
-> 3
-> 4
5 <-
-> 6
BSI No. F98E287 Page 2
Current New
Terminal Housing Color Harness Color Housing Color Harness Color
1 Blue Pink White Orange 2 Yellow Brown Yellow White 3 White Purple Blue Yellow 4 Blue Yellow White Purple 5 Yellow White Yellow Brown 6 White Orange Blue Pink
+ -- -- White Red
- -- -- White White
AC Wire-Harness Connection Diagram (MAIN SW area)
3. Change of logic circuit (PWA-LGC) In order to drive the power supply switch with the above magnetic reset function, the logic circuit has been changed. PWA-LGC has been changed to all regions.
(Details)
Connection of the 130 pin of IC31 (95CO63F) and the 14 pin of IC33 (62308F)l Connection of the 15 pin of IC33 (62308F) and the A9 pin of J8l To distinguish easily between the current and new logic PC boards, the color of the PC board l has been changed from white to yellow.
Note) The current logic PC board should never attached to machines complying with the
ENERGY STAR (Tier 2). If there is an excess current flow to the MAIN SW, it might possibly break.
Current
Color: White
(J326)
PWA-LGC
SSR
---- RSTSW
MAIN-SW
(-)
(+)
BSI No. F98E287 Page 3
IC31
(95C063F)
130 pin IC33
14 pin 15 pin
(62308F)
A9 pin
J8
Empty pin Empty pin
DG
New
IC31
(95C063F)
Color: yellow
Connection
130 pin
14 pin
IC33
(62308F)
Connection
15 pin
A9 pin
J8
CUT
DG
4. Wiring Change (Harness added) In order to drive the switch with the power supply magnetic reset function, the wiring has been changed as shown below.
Between the connector J8 (A9, A10) of the PWA-LGC and the MAIN switch (+, - terminal) have been connected by two new harnesses. Also, the harness of the PWA-LGC side is not considered as a service part but is a part of the previous harness (WH-LGC-HVT).
MAIN SW
(+)
(-)
Added harness (WH-RSTSW-154 / 4402322090)
* DC Connection Schematics Diagram (Area C6)
1 J326 1 2 2
J8-A10 J8-A9
Added harness * Included as part of current WH-LGC-HVT (N/A part)
BSI No. F98E287 Page 4
5. MAIN ROM change Addition of the electromagnetic reset function driving control of the MAIN SW. MAIN ROM has been changed to all regions.
(MAIN ROM Version) 5560: Ver 10 -> 11 6560: Ver 25 -> 26 7660, 7560:Ver 09 -> 10
[ Combinations of ROM Versions ]
The MAIN, LCD and PNL should never be operated except in the following combinations. As only the following combinations can have their operation checked, errors could well occur with other combinations.
5560 6560 7660,7560
MAIN 11 26 10
LCD 080 230 070 PNL 050 200 040
BSI No. F98E287 Page 5
5560 History of ROM Version
Serial No. MAIN LCD PNL
Application 1st Lot --- 05 050 050 ALL ALL F97F938 * Change of icon design
1997/6 --- 06 -- -- --- Change in Japanese only 1997/8 DH711273
---
1997/12 DL713426
1998/1 DA813693 1998/3 DC814950
1998/4 DD815523
07 070
07 070
08 080
09
10
11
080 050 ALL ALL F98A136 * Improvement of aging 080 050 ALL ALL F98C224 * Improvement of AC Key
080 050 ALL ALL F98E287 * Addition of MAIN SW
050 ALL -- F97I020 * Setting method of edge
050 -- ALL F97L104 * Expansion of adjustment
050 ALL ALL F97L107 * Change of quantity of
For LanguagesFactory Model Each
Language
BSI No. Contents
* Change of time display * Change in specifying
method of page number in sheet insertion mode
* Correction of error
during 2 in 1 copying.
erase and margin width.
* Correction of error for
access code input at standby
code setting value as a countermeasure to insufficient transfer
copies able to be stacked and stapled in the cover/sheet insertion mode
* Correction of jamming in
the sheet insertion mode
* Correction of poor
image visibility caused by the automatic sort setting value.
mode release method response for access
code standby. electromagnetic reset
function driving control
(ENERGY STAR Tier 2)
BSI No. F98E287 Page 6
6560 Change of ROM History
Serial No. MAIN LCD PNL
Application 1st Lot --- 18 180 180 ALL ALL --- ---
1997/3 MC711058
1997/4 MD711585 19
19 190
19 190 190
191 191
180 UC, GB-- F97E906 * Adjustment by user
For LanguagesFactory Model Each
Language
D, F I, E * Switch of Logo display
F -- F97E907 Corrected errors in French
BSI No Contents
Automatic Energy Saving/OFF Time
* Improving operability of
weekly timer setting cover/sheet insertion
* Addition of add paper
display for Cover/Sheet Insertion cassette
* Changeover of MG-2011
toward shift feeding of paper
* Countermeasure to
insufficient transfer during showing of the specified paper type
* LCD backlights go off
during timer off
* Errors corrected in
German and French display
1997/5 ME711921
1997/6 --- 21 -- -- --- Change in Japanese only 1997/8 MH712884
---
20 200 200
22 220
22 220
200 ALL -- F97I021 * Setting method of edge
200 -- ALL F97L105 * Expansion of adjustment
ALL ALL F97F937 * Change of icon design
* Change of time display * Change in specifying
method of page number in sheet insertion mode
* Correction of error
during 2 in 1 copying.
* Change in leading edge
adjustment setting value
* Adapted to the energy
star Tier 2.
* Adapted to the MG-2014
erase and margin width.
* Correction of error for
access code input at standby
code setting value as a countermeasure to insufficient transfer
BSI No. F98E287 Page 7
1997/12 ML714202
1998/1 MA814532 1998/3 MC815003
1998/4 MD815184
23 230
24
25
26
230 200 ALL ALL F98A137 * Improvement of aging 230 200 ALL ALL F98C225 * Improvement of AC Key
230 200 ALL ALL F98E287 * Addition of MAIN SW
200 ALL ALL F97L108 * Change of quantity of
copies able to be stacked and stapled in the cover/sheet insertion mode
* Correction of jamming in
the sheet insertion mode
* Correction of poor
image visibility caused by the automatic sort setting value.
mode release method response for access
code standby. electromagnetic reset
function driving control
(ENERGY STAR Tier 2)
BSI No. F98E287 Page 8
7660,7560 Change History of ROM Version
Serial No. MAIN LCD PNL
Application 1st Lot --- 04 040 040 ALL ALL F97F939 * Change of icon design
1997/6 --- 05 -- -- --- Change in Japanese only 1997/8 UH710507
---
1997/12 UL711031
1998/1 UA811216 1998/3 UC811354
1998/4 UD811405
06 060
06 060
07 070
08
09
10
070 040 ALL ALL F98A138 * Improvement of aging 070 040 ALL ALL F98C226 * Improvement of AC Key
070 040 ALL ALL F98E287 * Addition of MAIN SW
040 ALL -- F97I022 * Setting method of edge
040 -- ALL F97L106 * Expansion of adjustment
040 ALL ALL F97L109 * Change of quantity of
For LanguagesFactory Model Each
language
BSI No. Contents
* Change of time display * Change in specifying
method of page number in sheet insertion mode
* Correction of error
during 2 in 1 copying.
erase and margin width.
* Correction of error for
access code input at standby
code setting value as a countermeasure to insufficient transfer
copies able to be stacked and stapled in the cover/sheet insertion mode
* Correction of jamming in
the sheet insertion mode
* Correction of poor
image visibility caused by the automatic sort setting value.
* Correction of edit
position adjustment setting value
mode release method response for access
code standby. electromagnetic reset
function driving control
(ENERGY STAR Tier 2)
BSI No. F98E287 Page 9
6. Applied energy star label The energy star label (LBL-ENERGY-T) has been attached to the front cover.
7. Change of parts connected with the MAIN SW electromagnetic reset function The MAIN SW with the electromagnetic reset function is bigger than the current one. The following parts have been changed at the same time.
Also, (2), (3), (5) have been changed to all regions. (1) MAIN SW area cover (K-COVER-R-L-F-T)
(2) Angle (FRAME-AGL-F-EN) Change for all regions
(3) Angle bracket (BKT-ANGLE-F-EN) Change for all regions
(4) MAIN SW bracket (BKT-SW-MAIN)
BSI No. F98E287 Page 10
(5) Harness cover (COV-WH-AGL-F-EN) Change for all regions
BSI No. F98E287 Page 11
[Change/Addition Part No.] Parts enclosed by bold lines have been changed for all regions.
(Other parts have been changed for Europe only.)
MODELP/I Before Change After Change Note P I R ALL 3-1B 4401901170
K-COVER-R-L-F-T
ALL 6-1 4401787200
FRAME-AGL-F-EN
ALL 6-2 4401787290
BKT-ANGLE-F-EN
ALL 6-3B 4401787330
BKT-SW-MAIN
ALL 6-5B 4843231592
SW-AJ921100Z301
ALL 6-8 4401787610
COV-WH-AGL-F-EN
4402303100 K-COVER-R-L-F-T
4402303050 FRAME-AGL-F-EN
4402303060 BKT-ANGLE-F-EN
4402303070 BKT-SW-MAIN 4402322720 SZ-A8G109324
4402303080 COV-WH-AGL-F-EN
ALL 6-46B ---- 4402322090
WH-RSTSW-154
ALL 6-47B ---- 4843391656
WIRE/B-SKB-1M
ALL 1-54B ---- 4401910990
LBL-ENERGY-T
5560 64-14
101-0
5560 101-1 4402874210
6560 64-14
101-0
6560 101-1 4402321500
7660 7560 7660
64-14 101-0 101-1 4402889210
7560 5560 64-22 4402876290 6560 64-22 4402328040 7660
64-22 4402891380
7560
4402874140 PWA-F-LGC-155
PWB-F-LGC-155 4402321320
PWA-F-LGC-154 PWB-F-LGC-154 4402889160
PWA-F-LGC-156 PWB-F-LGC-156
PRA-155M-10 PRA-154M-25 PRA-156M-09
4402874150 PWA-F-LGC-155 4402874220 PWB-F-LGC-155
4402321330 PWA-F-LGC-154 4402321510 PWB-F-LGC-154
4402889170 PWA-F-LGC-156 4402889220 PWB-F-LGC-156
4402876300 PRA-155M-11 4402328050 PRA-154M-26 4402891390 PRA-156M-10
Applied to all regions (N/A parts) Applied to all regions
SW with electromagnetic reset function
Applied to all regions
Applied to all regions Applied to all regions (N/A parts) Applied to all regions Applied to all regions (N/A parts) Applied to all regions Applied to all regions (N/A parts) Applied to all regions Applied to all regions Applied to all regions
C D C
C D C
C D C C D C C D C
C B C A D C A D C A D C C B C C - C
C B C C - C
C B C C - C
C B C C B C C B C
P: Contents of Change I: Interchangeability R: Reasons for Change