2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F98E287
SUBJECT
ENERGY STAR/ Tier 2 (Europe)
MODEL
CATEGORY
Safety standard Related
From Apr. 1998
5560: DD815523
6560: MD815184
7660,7560: UD811405
CONTENT
To comply with the standard value of ENERGY STAR (Tier 2) for Europe (EUD, GSD, FRD, SED,
UKD) in the above models, the following changes have been made. Also, for conformity with other
parts, some changes have been made for regions other than Europe.
5560, 6560, 7560, 7660
FIELD APPLICATION
Others
FACTORY APPLICATION
Date
98/05/27
DTM-F8110/8202/8205/8310
UNIT
Other, Software, Electrical
Circuit
[ Changed Content ]
1. Setting change of Auto Power Save and Auto Shut-Off Mode at the time of shipment
Setting at the time of shipment in the above modes has been made not to permit operation but
the setting values have been changed as follows.
Before ChangeAfter Change
Auto energy saving
(08-11)
Auto shut-off
(08-56)
Note) *The power switch automatically goes off when the [Auto shut-off] mode is operated.
Return to the READY condition can be made by turning the power switch ON.
* Operation time of [Auto energy saving] [Auto shut-off] can be extended to a maximum of
240 minutes.
*The power supply OFF in the [Auto shut-off] mode has priority over the Weekly Timer.
Therefore, when the power supply is turned off in the [Auto shut-off] mode, the power
return function of the Weekly Timer cannot operated.
*If the setting value changes, refer to BSI/F98C249.
2. Change of power supply switch to one with an electromagnetic reset function
In order to be able to reset the MAIN SW using software, change has been made to the power
supply switch by giving it an electromagnetic reset function. This switch has a MAIN SW inside
coil for resetting and the switch goes off when DC24V is added to the coil.
The combination of the switch terminal and the harness connection has also been changed as
shown below.
0
(No function)
20
(No function)
3
(Function after fifteen minutes)
12
(Function after ninety minutes)
Coil for reset
-> 1
2 <-
-> 3
-> 4
5 <-
-> 6
BSI No. F98E287 Page 2
CurrentNew
TerminalHousing ColorHarness ColorHousing ColorHarness Color
3. Change of logic circuit (PWA-LGC)
In order to drive the power supply switch with the above magnetic reset function, the logic circuit
has been changed.
PWA-LGC has been changed to all regions.
(Details)
Connection of the 130 pin of IC31 (95CO63F) and the 14 pin of IC33 (62308F)l
Connection of the 15 pin of IC33 (62308F) and the A9 pin of J8l
To distinguish easily between the current and new logic PC boards, the color of the PC board l
has been changed from white to yellow.
Note) The current logic PC board should never attached to machines complying with the
ENERGY STAR (Tier 2).
If there is an excess current flow to the MAIN SW, it might possibly break.
Current
Color: White
(J326)
PWA-LGC
SSR
---- RSTSW
MAIN-SW
(-)
(+)
BSI No. F98E287 Page 3
IC31
(95C063F)
130 pinIC33
14 pin15 pin
(62308F)
A9 pin
J8
Empty pinEmpty pin
DG
New
IC31
(95C063F)
Color: yellow
Connection
130 pin
14 pin
IC33
(62308F)
Connection
15 pin
A9 pin
J8
CUT
DG
4. Wiring Change (Harness added)
In order to drive the switch with the power supply magnetic reset function, the wiring has been
changed as shown below.
Between the connector J8 (A9, A10) of the PWA-LGC and the MAIN switch (+, - terminal) have
been connected by two new harnesses.
Also, the harness of the PWA-LGC side is not considered as a service part but is a part of the
previous harness (WH-LGC-HVT).
MAIN SW
(+)
(-)
Added harness
(WH-RSTSW-154 / 4402322090)
* DC Connection Schematics Diagram (Area C6)
1J326 1
22
J8-A10
J8-A9
Added harness
* Included as part of current
WH-LGC-HVT (N/A part)
BSI No. F98E287 Page 4
5. MAIN ROM change
Addition of the electromagnetic reset function driving control of the MAIN SW.
MAIN ROM has been changed to all regions.
(MAIN ROM Version)
5560: Ver 10 -> 11
6560: Ver 25 -> 26
7660, 7560:Ver 09 -> 10
[ Combinations of ROM Versions ]
The MAIN, LCD and PNL should never be operated except in the following combinations. As
only the following combinations can have their operation checked, errors could well occur
with other combinations.
556065607660,7560
MAIN112610
LCD080230070
PNL050200040
BSI No. F98E287 Page 5
5560 History of ROM Version
Serial No. MAIN LCDPNL
Application
1st Lot---05050050ALLALLF97F938 * Change of icon design
1997/6---06-------Change in Japanese only
1997/8DH711273
---
1997/12DL713426
1998/1DA813693
1998/3DC814950
1998/4DD815523
07070
07070
08080
09
10
11
080050ALLALLF98A136 * Improvement of aging
080050ALLALLF98C224 * Improvement of AC Key
080050ALLALLF98E287 * Addition of MAIN SW
050ALL--F97I020 * Setting method of edge
050--ALLF97L104 * Expansion of adjustment
050ALLALLF97L107 * Change of quantity of
For LanguagesFactory
Model Each
Language
BSI No.Contents
* Change of time display
* Change in specifying
method of page number
in sheet insertion mode
* Correction of error
during 2 in 1 copying.
erase and margin width.
* Correction of error for
access code input at
standby
code setting value as a
countermeasure to
insufficient transfer
copies able to be
stacked and stapled in
the cover/sheet insertion
mode
* Correction of jamming in
the sheet insertion mode
* Correction of poor
image visibility caused
by the automatic sort
setting value.
mode release method
response for access
code standby.
electromagnetic reset
function driving control
(ENERGY STAR Tier 2)
BSI No. F98E287 Page 6
6560 Change of ROM History
Serial No. MAIN LCDPNL
Application
1st Lot---18180180ALLALL------
1997/3MC711058
1997/4MD711585 19
19190
19190190
191191
180UC, GB--F97E906 * Adjustment by user
For LanguagesFactory
Model Each
Language
D, FI, E* Switch of Logo display
F--F97E907 Corrected errors in French
BSI NoContents
Automatic Energy
Saving/OFF Time
* Improving operability of
weekly timer setting
cover/sheet insertion
* Addition of add paper
display for Cover/Sheet
Insertion cassette
* Changeover of MG-2011
toward shift feeding of
paper
* Countermeasure to
insufficient transfer
during showing of the
specified paper type
* LCD backlights go off
during timer off
* Errors corrected in
German and French
display
1997/5ME711921
1997/6---21-------Change in Japanese only
1997/8MH712884
---
20200200
22220
22220
200ALL--F97I021 * Setting method of edge
200--ALLF97L105 * Expansion of adjustment
ALLALLF97F937 * Change of icon design
* Change of time display
* Change in specifying
method of page number
in sheet insertion mode
* Correction of error
during 2 in 1 copying.
* Change in leading edge
adjustment setting value
* Adapted to the energy
star Tier 2.
* Adapted to the MG-2014
erase and margin width.
* Correction of error for
access code input at
standby
code setting value as a
countermeasure to
insufficient transfer
BSI No. F98E287 Page 7
1997/12ML714202
1998/1MA814532
1998/3MC815003
1998/4MD815184
23230
24
25
26
230200ALLALLF98A137 * Improvement of aging
230200ALLALLF98C225 * Improvement of AC Key
230200ALLALLF98E287 * Addition of MAIN SW
200ALLALLF97L108 * Change of quantity of
copies able to be
stacked and stapled in
the cover/sheet insertion
mode
* Correction of jamming in
the sheet insertion mode
* Correction of poor
image visibility caused
by the automatic sort
setting value.
mode release method
response for access
code standby.
electromagnetic reset
function driving control
(ENERGY STAR Tier 2)
BSI No. F98E287 Page 8
7660,7560 Change History of ROM Version
Serial No. MAIN LCDPNL
Application
1st Lot---04040040ALLALLF97F939 * Change of icon design
1997/6---05-------Change in Japanese only
1997/8UH710507
---
1997/12UL711031
1998/1UA811216
1998/3UC811354
1998/4UD811405
06060
06060
07070
08
09
10
070040ALLALLF98A138 * Improvement of aging
070040ALLALLF98C226 * Improvement of AC Key
070040ALLALLF98E287 * Addition of MAIN SW
040ALL--F97I022 * Setting method of edge
040--ALLF97L106 * Expansion of adjustment
040ALLALLF97L109 * Change of quantity of
For LanguagesFactory
Model Each
language
BSI No.Contents
* Change of time display
* Change in specifying
method of page number
in sheet insertion mode
* Correction of error
during 2 in 1 copying.
erase and margin width.
* Correction of error for
access code input at
standby
code setting value as a
countermeasure to
insufficient transfer
copies able to be
stacked and stapled in
the cover/sheet insertion
mode
* Correction of jamming in
the sheet insertion mode
* Correction of poor
image visibility caused
by the automatic sort
setting value.
* Correction of edit
position adjustment
setting value
mode release method
response for access
code standby.
electromagnetic reset
function driving control
(ENERGY STAR Tier 2)
BSI No. F98E287 Page 9
6. Applied energy star label
The energy star label (LBL-ENERGY-T) has been attached to the front cover.
7. Change of parts connected with the MAIN SW electromagnetic reset function
The MAIN SW with the electromagnetic reset function is bigger than the current one. The
following parts have been changed at the same time.
Also, (2), (3), (5) have been changed to all regions.
(1) MAIN SW area cover (K-COVER-R-L-F-T)
(2) Angle (FRAME-AGL-F-EN) Change for all regions
(3) Angle bracket (BKT-ANGLE-F-EN) Change for all regions
(4) MAIN SW bracket (BKT-SW-MAIN)
BSI No. F98E287 Page 10
(5) Harness cover (COV-WH-AGL-F-EN) Change for all regions
BSI No. F98E287 Page 11
[Change/Addition Part No.]
Parts enclosed by bold lines have been changed for all regions.
Applied to all
regions
(N/A parts)
Applied to all
regions
SW with
electromagnetic
reset function
Applied to all
regions
Applied to all
regions
Applied to all
regions
(N/A parts)
Applied to all
regions
Applied to all
regions
(N/A parts)
Applied to all
regions
Applied to all
regions
(N/A parts)
Applied to all
regions
Applied to all
regions
Applied to all
regions
CDC
CDC
CDC
CDC
CDC
CBC
ADC
ADC
ADC
CBC
C-C
CBC
C-C
CBC
C-C
CBC
CBC
CBC
P: Contents of Change I: Interchangeability R: Reasons for Change
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.