Separation Pad Change
MODEL
CATEGORY
Countermeasure to field trouble, Treatment in the field
From May 1998 at the factory
CONTENT
Error content When a original feeding jam is being cleared and the original is pulled out in the direction of the original tray without the jam cover being opened, the boss at the bottom side of the separation pad holder may become removed from the fixing bracket. If in this condition the jam cover is opened, pressure will be brought to bear on the pin of the separation pad holder and in some cases it may even become broken.
MR2008, MR3006, MR3006A, MR3006E
FIELD APPLICATION
Others
FACTORY APPLICATION
UNIT
ADF
Date
98/05/13
DTM-F8411
Countermeasure Even if the original is pulled out without opening the jam cover, the separation pad holder no longer becomes removed from the bracket because the boss at the bottom of the separation pad holder has been changed. (see "A").
A
K-HLDR-PAD
Part Name Holder
Countermeasure in the field Since the original could be damaged by its being removed without the jam cover being opened at the time of a paper feeding jam, thorough instructions should be given never to remove the original in the direction of the original tray when not first having opened the jam cover.
Page-Item 1-100
Before Change After Change Note
4408690690 K-HLDR-PAD
4408692060 K-HLDR-PAD
---- B
Interchangeability