BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F98C251
SUBJECT
Change of Installation Method of Scanning Motor
Date
98/03/26
MODEL
CATEGORY
To improve the productivity
From Mar. 1998 at the factory
CONTENT
To improve the productivity, the following parts have been changed to fit in with step 4 of "the
Scanning Motor Installation Method" "temporarily loosely tighten screw B"
alteration in step 4, the installation method has also been changed.
Notes) Since some parts are not interchangeable, pay attention to the following points when
Part Name
Bracket 5-21
Screw 5-62
Screw 5-63
Bush 5-64
4560, 4570
FACTORY APPLICATION
exchanging parts.
Page-Item Before Change After Change Notes Interchangeability
FIELD APPLICATION
Others
4402457380
BRKT-MOT-SCAN
7640400851
ZPAN40*08MSZN3A
----- 4842040061
----- 4408302680
4402457910
BRKT-MOT-SCAN
<---
TPAN40*10MSZN3L
BUSH-BRKT-SCAN
UNIT
Optical
. Accompanying this
2 screws -->
1 screw
Screw B
Screw D
B
B
B
B
-Installation of Scanning Motor-
Current
1. Open the upper unit.
2. Hang the wire drive belt on the scanning motor
pulley.
3. Hook the tension spring on the copier's frame.
4. Hang the wire drive belt on the belt drive pulley, and
temporarily loosely tighten screw B.
installed yet.)
5. Make sure 2 ~ 3 times that the scanning motor is
returned to its previous position by the tension spring
even if the scanning motor is rotated in the direction of
the arrow C.
6. At that position, while pressing the scanning motor to
the machine frame, tighten the screw A (when
tightening the screw A, be careful not to move the
scanning motor).
7. Tighten the screw B.
(Screw A is not
Change Points
4. Hang the wire drive belt on the belt
drive pulley, and after inserting the
bush in the bracket hole, install
screw B. (Temporarily fix screw A
loosely but do not install screw D.)
7. Tighten screw D.