Toshiba f98c249 Service Note

BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F98C249
SUBJECT
MODEL
CATEGORY
Other
-----
CONTENT
For those products to which ENERGY STAR is applied, the Default Time (the Low Power Mode and the Off Mode) and Auto-Duplex are set. If any of these are to be changed during servicing, care must be taken that they follow the ENERGY STAR standards without fail.
1. Change of Default Time
General
FIELD APPLICATION
To be applied when necessary
FACTORY APPLICATION
If inconvenience of a considerable extent has occurred to a user, the time can be extended. However, in keeping with the standards, the total Default Time (Off Mode and Low Power Mode) must not exceed 240 minutes.
UNIT
Other
Date
98/03/25
-----
2. To disable the Off Mode To gain understanding for ENERGY STAR's aims, even though use is perfectly recommendable in this extended-time condition, the Off Mode should only be disabled, if there are strong arguments concerning this from the user. Be careful, since disabling of the Low Power Mode must not be executed in accordance with the ENERGY STAR standards.
3. Auto-Duplex In copier with a speed of above 44 CPM, Auto-Duplex is ON in the Default value. If Auto-Duplex is ON in the Default value, this can be disabled if the user so desires based on his particular conditions of use. Also, since there has been a change to the ENERGY STAR (Tier 2) standards, it is no longer necessary for Auto-Duplex to be ON in the Default value. It is scheduled for this change to be made in turn to copiers being shipped. * Refer to the contents of a separate information sheet (BSI) for the relevant information.
4. Changing method Follow the methods prescribed in the relevant service handbooks or BSIs regarding changing or disabling the Default Time and Auto-Duplex.
5. About ENERGY STAR Environmental problems, of which global warming is the foremost, are closely connected with a daily energy consumption philosophy. Energy saving for office automation equipment has become an important topic throughout the world. In this respect, automatic energy saving standards have been established for office automation equipment, for which it would be rather problematic to turn off the main power source. In response, the "International Energy Star Problem" was established based on an agreement made by the governments of Japan and the United States.
BSI No. F98C249 Page 2
The above label can be attached to machines which satisfy the standards of the "International Energy Star Program". In order to satisfy these standards, these machines are set at the time of shipping from the factory in such a way so as when left in the standby condition, they will automatically go into the Low Power Mode and the Off Mode after a fixed time. If the machines are used in accordance with the setting made in the factory at the time of shipping, then they can be regarded as complying with the energy saving philosophy as propagated in the "International Energy Star Program" standards. However, once the Low Power Mode or Off Mode has been entered, recovery time will be necessary to return to the standby condition to enable copying to be performed again. Therefore, even at the risk of slightly reducing the efficacy of the energy saving program, it is necessary to be able to respond to the needs of users who want to be able to make copies immediately at any time.
In case like this, after having explained the aims of the "International Energy Star Program" to the user, it would still be within the standards to extend the transfer timer. Moreover, even if use is being made of an extended transfer timer, when the user expresses a strong desire for there to be no transfer to the Off Mode, then, and only then, is it still within the standards for a change to be made preventing such entry into the Off Mode.
6. Standard values
Tier-1 Products shipped between July 1st 1995 and June 30 1997
CPM Off Mode
(Watts) 0<CPM=<20 <5 =<30 minutes No ­20<CPM=<44 <40 =<60 minutes Optional 2540,3240,3550 44<CPM <40 =<90 minutes Default 7650
Tier-2 Products shipped from July 1st 1997
CPM Low Power
Mode (Watts)
CPM=<20 None NA =<30 minutes <5 =<30 minutes 1370,1560,2060 20<CPM=<44 3.85 x CPM +5 =<30sec =<60 minutes <15 =<60 minutes 3560,2860 44<CPM 3.85 x CPM +5 =<30sec
Off Mode Default Time
Recovery Time Low Power
Recommended
Auto-Duplex Mode
Mode Default Time
=<90 minutes <20 =<90 minutes 4560,5560,6560