BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F98C243
SUBJECT
Change of PROM
MODEL
CATEGORY
To improve the reliability
From Apr. 1998 at the factory
CONTENT
Error Contents
If the power supply is quickly switched ON/OFF during the automatic energy saving mode, a signal
error (C54) will result.
Course and Countermeasure
MG2009, MG2009A
FIELD APPLICATION
To be applied when necessary
FACTORY APPLICATION
When the automatic energy saving mode is set and a sorter sleep signal (ON) is sent from the
copier to the sorter, the sorter will also go into the automatic energy saving mode. If the above
happens and the power is switched OFF/ON quickly, a start signal other than the sorter sleep
signal (OFF) will be caused. and a signal error will result. A change has now been made to prevent
the occurrence of such an error even in the automatic energy saving mode, so that the start signal
is accepted.
UNIT
Sorter
Date
98/03/30
DTM-F8301
Part Name
ROM 2-26
Label
Page-Item Current New Remarks Interchangeability
4400791660
PRA-772SRT-07
4F1-0378
1.2.3.4.5.6.
7.8.9.10.20
4400791670
PRA-772SRT-08
4F1-0378
1.2.3.4.5.6.
7.8.9.10.20
---- B