Toshiba f98c225 Service Note

Page 1
BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F98C225
SUBJECT
MODEL
CATEGORY
To improve the operability
From Mar. 1998/ MC815003
CONTENT
The following items have been changed.
Item
6560
FIELD APPLICATION
To be applied when necessary
FACTORY APPLICATION
Contents
If use is made of job access codes, after the end of copying, when one presses the
1
"FUNCTION CLEAR" key twice, the machine changes from "copy standby" to "access code standby". However, the key should not be pressed two times immediately, but a gap of at least two seconds should have been left between each pressing, or the "access code standby" could not be obtained. The "FUNCTION CLEAR" key has now been improved so that "access code standby" can be obtained even if the key is pressed twice quickly in succession.
Date
UNIT
Software
98/03/12
DTM-F8205
[ Combinations of ROM Versions ]
The MAIN, LCD and PNL should never be operated except in the following combinations. As only the following combinations can have their operation checked, errors could well occur with other combinations.
MAIN: Ver. 25 LCD: Ver. 230 ( There is no change of the LCD ROM ) PNL: Ver. 200 ( There is no change of the PNL ROM )
[ MAIN ROM Changed Part Number ] Version 24 -> 25
Page-Item 64-22
Before Change After Change Languages Machine Region Interchangeabilit
y
4402328030 PRA-154M-24
4402328040 PRA-154M-25
Common Common B
Page 2
BSI No. F98C225 Page 2
Change History of ROM Version
No. MAIN LCD PNL
Application 1st Lot --- 18 180 180 ALL ALL --- ---
1997/3 MC711058
1997/4 MD711585 19 1997/5 ME711921
1997/6 --- 21 -- -- --- Change in Japanese only 1997/8 MH712884
---
19 190
19 190 190
191 191
20 200 200
22 220
22 220
For LanguagesFactory Model Each
Language
180 UC,
GB
D, F I, E * Switch of Logo display
F -- F97E907 Corrected errors in
ALL ALL F97F937 * Change of icon design
200 ALL -- F97I021 * Setting method of edge
200 -- ALL F97L105 * Expansion of adjustment
-- F97E906 * Adjustment by user
BSI No Contents
Automatic Energy Saving/OFF Time
* Improving operability of
weekly timer setting cover/sheet insertion
* Addition of add paper
display for Cover/Sheet Insertion cassette
* Changeover of
MG-2011 toward shift feeding of paper
* Countermeasure to
insufficient transfer during showing of the specified paper type
* LCD backlights go off
during timer off
* Errors collected in
German and French
display French * Change of time display
* Change in specifying
method of page number
in sheet insertion mode * Correction of error
during 2 in 1 copying. * Change in leading edge
adjustment setting value * Adapted to the energy
star Tier 2. * Adapted to the MG-2014
erase and margin width. * Correction of error for
code input at standby
code setting value as a
countermeasure to
insufficient transfer
Page 3
BSI No. F98C225 Page 3
1997/12 ML714202
1998/1 MA814532 1998/3 MC815003
UC: American, GB: English, D: German, F: French, I: Italian, E: Spanish
23 230
230 200 ALL ALL F98A137 * Improvement of aging
24
230 200 ALL ALL F98C225 * Improvement of AC Key
25
200 ALL ALL F97L108 * Change of quantity of
copies able to be
stacked and stapled in
the cover/sheet insertion
mode * Correction of jamming in
the sheet insertion mode * Correction of poor
image visibility caused
by the automatic sort
setting value.
mode release method
response for access code standby.
Loading...