Toshiba f98c224 Service Note

BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F98C224
SUBJECT
MODEL
CATEGORY
To improve the operability
From Mar. 1998/ DC814950
CONTENT
The following items have been changed.
Item
5560
FIELD APPLICATION
To be applied when necessary
FACTORY APPLICATION
Contents
If use is made of job access codes, after the end of copying, when one presses the
1
"Function Clear key" twice, the machine changes from "copy standby" to "access code standby". However, the key should not be pressed two times immediately, but a gap of at least two seconds should have been left between each pressing, or the "access code standby" could not be obtained. The "Function Clear key" has now been improved so that "access code standby" can be obtained even if the key is pressed twice quickly in succession.
Date
UNIT
Software
98/03/17
DTM-F8205
[ Combinations of ROM Versions ]
The MAIN, LCD and PNL should never be operated except in the following combinations. As only the following combinations can have their operation checked, errors could well occur with other combinations.
MAIN: Ver. 10 LCD: Ver. 080 ( There is no change of the LCD ROM ) PNL: Ver. 050 ( There is no change of the PNL ROM )
[ MAIN ROM Changed Part Number ] Version 09 -> 10
Page-Item 64-22
Before Change After Change Languages Machine Region
4402876280 PRA-155M-09
4402876290 PRA-155M-10
Common Common B
Interchangeability
BSI No. F98C224 Page 2
Change History of ROM Version
No. MAIN LCD PNL
Application 1st Lot --- 05 050 050 ALL ALL F97F938 * Change of icon design
1997/6 --- 06 -- -- --- Change in Japanese only 1997/8 DH711273
---
1997/12 DL713426
1998/1 DA813693 1998/3 DC814950
07 070
07 070
08 080
080 050 ALL ALL F98A136 * Improvement of aging
09
080 050 ALL ALL F98C224 * Improvement of AC Key
10
For LanguagesFactory Model Each
Language
050 ALL -- F97I020 * Setting method of edge
050 -- ALL F97L104 * Expansion of adjustment
050 ALL ALL F97L107 * Change of quantity of
BSI No. Contents
* Change of time display * Change in specifying
method of page number in sheet insertion mode
* Correction of error
during 2 in 1 copying.
erase and margin width.
* Correction of error for
code input at standby code setting value as a
countermeasure to insufficient transfer
copies able to be stacked and stapled in the cover/sheet insertion mode
* Correction of jamming in
the sheet insertion mode
* Correction of poor
image visibility caused by the automatic sort setting value.
mode release method response for access
code standby.
Loading...