BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F98A167
SUBJECT
Error Code (Service Handbook)
Date
98/02/16
MODEL
CATEGORY
Correction of Service Manual
-
CONTENT
Service Handbook
Some omissions have been found in the above Section, which have been corrected as shown in the
following table.
Group
Copier transport
jam
System - Logic
Abnormal signal
DP2460
FACTORY APPLICATION
1. Adjustment Items
1.1 Error Codes
Error
Code
EB5
F07
FIELD APPLICATION
Others
Machine Status
When the specified time to reach the paper stop switch 1 is passed
and the paper does not arrive, a time out error occurs.
Note)
* Usually this does not occur.
(At first, other error code jams are detected.)
* When the size plate setting and the actual paper size are different, it
may occur. When it does happen, the size plate and the paper size
should be made to match.
*To furthre prevent the possibility of an EB5 Error Code from
occurring, the Other Key / Standard Size must be programmed
to the size of paper placed in the Other Drawer when the Size
Plate is set to "OTHER".
Abnormal signal between the system PC board and the logic PC
board
UNIT
Other
Error results from the following causes
* Error of insertion of the P-ROM(IC42) in the logic PC board
* Error of harness connection between the system and the logic PC
board
* Error of logic PC board