SUBJECT
Change of ROM/ MAIN ROM Ver. 23 -> 24
MODEL
CATEGORY
To improve the operability
From Jan. 1998
CONTENT
The following items have been changed.
Item
1
6560
FIELD APPLICATION
To be applied when necessary
FACTORY APPLICATION
Contents
The aging mode (02 or 07) can be cleared by pushing digital keys " 0 and 9" on the
control panel at the same time.
Date
UNIT
Software
98/01/20
DTM-F7Z12
Note: Though the method of the aging mode release (pushing digital keys" 0/9") is
given as listed in the Service Manual, the machine with the current version of the
MAIN ROM cannot be cleared by this method. It should be cleared by turning
ON/OFF the power.
[ Combinations of ROM Versions ]
The MAIN, LCD and PNL should never be operated except in the following combinations. As
only the following combinations can have their operation checked errors could well occur
with other combinations.
MAIN: Ver. 24
LCD: Ver. 230 ( There is no change of the LCD ROM )
PNL: Ver. 200 ( There is no change of the PNL ROM )
[ MAIN ROM Changed Part Number ] Version 23 -> 24
Page-Item
64-22
Current New Languages Machine Region
4402327590
PRA-154M-23
4402328030
PRA-154M-24
Common Common B
Interchangeability

BSI No. F98A137 Page 2
Change History of ROM Version
No. MAIN LCD PNL
Application
1st Lot --- 18 180 180 ALL ALL --- ---
1997/3 MC711058
1997/4 MD711585 19
1997/5 ME711921
1997/6 --- 21 -- -- --- Change in Japanese only
1997/8 MH712884
---
19 190
19 190 190
191 191
20 200 200
22 220
22 220
For LanguagesFactory
Model Each
language
180 UC,
GB
D, F I, E * Switch of Logo display
F -- F97E907 Corrected errors in
ALL ALL F97F937 * Change of icon design
200 ALL -- F97I021 * Setting method of edge
200 -- ALL F97L105 * Expansion of adjustment
-- F97E906 * Adjustment by user
BSI No Contents
Automatic Energy
Saving/OFF Time
* Improving operability of
weekly timer setting
cover/sheet insertion
* Addition of add paper
display for Cover/Sheet
Insertion cassette
* Changeover of
MG-2011 toward shift
feeding of paper
* Countermeasure to
insufficient transfer
during showing of the
specified paper type
* LCD backlights go off
during timer off
* Errors collected in
German and French
display
French
* Change of time display
* Change in specifying
method of page number
in sheet insertion mode
* Correction of error
during 2 in 1 copying.
* Change in leading edge
adjustment setting value
* Adapted to the energy
star Tier 2.
* Adapted to the MG-2014
erase and margin width.
* Correction of error for
code input at standby
code setting value as a
countermeasure to
insufficient transfer

BSI No. F98A137 Page 3
1997/12 ML714202
1998/1
UC: American, GB: English, D: German, F: French, I: Italian, E: Spanish
23 230
230 200 ALL ALL F98A137 Improvement of aging
24
200 ALL ALL F97L108 * Change of quantity of
copies able to be
stacked and stapled in
the cover/sheet insertion
mode
* Correction of jamming in
the sheet insertion mode
* Correction of poor
image visibility caused
by the automatic sort
setting value.
mode release method