Toshiba f97l100 Service Note

BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F97L100
SUBJECT
MODEL
CATEGORY
Treatment in the field, To improve the reliability
From Nov. 1997 at the factory
CONTENT
Phenomenon During setting of the sort/group mode, shift misfeeding to the front may be caused when the first copy sheet exits. Cause If the dimension of the standard board (P11/Item 6) in the front side is in the vicinity of the max. tolerance, the standard board convex portion may interface with the end face of the staple tray notch portion (P11/Item 50). If it becomes caught, the solenoid cannot be pulled out because it has too much attraction force. As a result, pulled shift misfeeding of the standard board occurs and of the copy paper.
MJ1003
FIELD APPLICATION
To be applied when necessary
FACTORY APPLICATION
Date
UNIT
Finisher
97/12/17
DTM-F7Z03
Countermeasure Contents 1 washer (0.5 mm) has been added to the shaft of the standard board (rear side) and the above standard board convex portion cannot interface with the staple tray.
Added Part
Part Name Page-Item Current New Remarks Interchangeability
Washer 11-53
---------- 4402352950 WASHER
Addition ----
Added washer
When the standard board is shifted, the end face of the standard board interfaces with the notch portion of the staple tray.
Standard
board
Solenoid of standard board
BSI No. F97L100 Page 2