SUBJECT
Countermeasure to Shift Misfeeding (MJ1003 Job Offset Mode)
MODEL
CATEGORY
Treatment in the field, To
improve the reliability
From Nov. 1997 at the factory
CONTENT
Phenomenon
During setting of the sort/group mode, shift misfeeding to the front may be caused when the first copy
sheet exits.
Cause
If the dimension of the standard board (P11/Item 6) in the front side is in the vicinity of the max.
tolerance, the standard board convex portion may interface with the end face of the staple tray notch
portion (P11/Item 50). If it becomes caught, the solenoid cannot be pulled out because it has too
much attraction force. As a result, pulled shift misfeeding of the standard board occurs and of the
copy paper.
MJ1003
FIELD APPLICATION
To be applied when necessary
FACTORY APPLICATION
Date
UNIT
Finisher
97/12/17
DTM-F7Z03
Countermeasure Contents
1 washer (0.5 mm) has been added to the shaft of the standard board (rear side) and the above
standard board convex portion cannot interface with the staple tray.
Added Part
Part Name Page-Item Current New Remarks Interchangeability
Washer 11-53
---------- 4402352950
WASHER
Addition ----
When the standard board is shifted, the end face of the standard
board interfaces with the notch portion of the staple tray.
Standard
board
Solenoid of standard board
BSI No. F97L100 Page 2