BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F97I008
SUBJECT
ROM Version Improvement (Ver. 15 to 16)
MODEL
CATEGORY
To improve the reliability
From Jul. 1997
CONTENT
In the current ROM, when the dual-page copying function has been used with the optional PFU
(MY-1004) attached and paper for PFU in A4, B5 and LT sizes is fed, jam may result at the time of
the changing from the left to right side copying.
The ROM has been changed in order to eliminate this trouble.
1550
FIELD APPLICATION
Others
FACTORY APPLICATION
Date
97/10/13
UNIT
Electrical Circuit
DTM-F7607
Page-Item
5-15
Note 1.) Even if the current ROM is used, there is no problem in feeding from the upper cassette
Note 2.) If the MY-1004 is not installed, there is no difference resulting from the ROM change.
Current New Remarks
4400679970
PRA-T140M-15
only.
4400679980
PRA-T140M-16
Ver.15 to
Ver.16
Interchangeability
B