Toshiba f97i001 Service Note

BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F97I001
SUBJECT
MODEL
CATEGORY
To improve the reliability
UC710131~
CONTENT
Since the image density concentration may be lowered by abnormalities in the surface potential sensor, the following part has been changed.
Page No. Current New New Part Name Interchangeability 10 25 4402404500 4402429120 PWB-DETECTING ASSY B
FC70
FIELD APPLICATION
To be applied when necessary
FACTORY APPLICATION
Date
UNIT
Developer
97/09/26
----
Cause If the covering of the cable inside the VO sensor Assy (01) contacts the frame, it can break and a short can result. Then, the image density may be lowered because the image stability control no longer functions normally. If the VO sensor behaves abnormally, then the CALL SERVICE or the MAINTENANCE symbol will flash on the graphic display. Measure in field Change the VO sensor assembly in the serviceman mode if the image stability has become abnormal due to the VO sensor no longer functioning properly (it is also possible that the charger and the Vg may be broken as well).
Countermeasure The wire is to be fixed by silicon.
Inside sensor
BSI No. F97I001 Page 2
Frame Wire
Sensor
Silicon
Wire
Silicon