Toshiba f97h989 Service Note

BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F97H989
SUBJECT
MODEL
CATEGORY
To improve the productivity
From Jan. 1997
CONTENT
[ Phenomenon ] Due to an error in the assembly of the main charger timing belt (wrong positioning of the LED eraser array cleaner base), the cleaner motor (M8) can become lightly locked during cleaning.
[ Cause ] When the LED eraser array cleaner base is installed to the timing belt, it has to be aligned to the mark on the charger guide. However, due to the angle, the belt could be about 1 tooth out of position, but still seem to have been aligned correctly and thus installed in a wrong position.
6560
FIELD APPLICATION
Others
FACTORY APPLICATION
Date
97/09/20
UNIT
Drum related
DTM-F6Y15
[ Countermeasure ] By making 2 marks, the angle of vision at the time of assembly has been adjusted.
Mark (1 place)
[ Changed Part Number ]
Part Name Charger Guide
Current New Interchangeability 4402308100 K-GUIDE-CH-L
Belt
Mark Mark
LED eraser array cleaner base (P47/Item 8)
Pusher switch (P47/Item11)
4402308010 K-GUIDE-CH-L
E