BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F97H988
SUBJECT
Countermeasure to Imperfect Operation of LCF Tray
MODEL
CATEGORY
Other countermeasures
From Apr. 1997
CONTENT
[Developing]
When the copier is in a low-temperature environment, the LCF tray may become unstable and get
caught part of the way down.
[ Cause ]
The wire hanging on to the tray is stretched by its own weight and in a low-tempererature
environment, it will become stiff, making the movement of the tray unstable.
6560, 7550, 7650
FIELD APPLICATION
To be applied when necessary
FACTORY APPLICATION
UNIT
LCF
Date
97/09/18
DTM-F7407
[ Countermeasure ]
Sheet metal has been added to the tray, making it heavier and thus the tray can be lowered smoothly
even in a low-temperature environment.
Fixed by 4 screws
Tray
Added sheet metal
[ Newly Added Part ]
Part Name
Part No./Name
Interchangeability

BSI No. F97H988 Page 2
LCF Tray
Base
4402867000
K-BASE-TRAY-LCF
--